1. Catalogs
  2. VPT Inc
  3. SVTR2800S SERIES

SVTR2800S SERIES

SVTR2800S SERIES
1 / 16 PagesView full catalog

SVTR2800S SERIES

Product catalog summary
Overview
The SVTR2800S Series is a line of space-qualified hybrid DC-DC converters designed for harsh radiation environments in space applications. These converters are characterized for Total Ionizing Dose (TID) and Single Event Effects (SEE) and are suitable for use in various orbits and deep space missions.
Specifications
  • Input Voltage: 15 V to 50 V continuous, 80 V transient
  • Output Power: Up to 40 W
  • Output Voltages: 3.3 V, 5 V, 8 V, 12 V, 15 V
  • Operating Temperature: -55 °C to +125 °C
  • Qualified to MIL-PRF-38534 Class H and Class K
Features
  • Wide input voltage range
  • Low output noise
  • Radiation immune magnetic feedback circuit
  • Current limit and short circuit protection
  • No optoisolators used
Performance Specifications
  • Efficiency ranges from 65% to 85% depending on the model
  • Ripple current and voltage specifications are provided for various conditions
  • Load and line regulation details are specified
Mechanical and Compliance
  • Low-profile packaging with flanged and non-flanged options
  • Weight: Max 55 g
  • Compliance with MIL-STD-461 and ISO-9001
Technical Notes
  • The converter uses a flyback topology with magnetic feedback for isolation
  • No external components are required for operation
  • The output can be configured as positive or negative voltage
  • On/Off control is managed via the INH pin
Diagrams and Pinout
Block and connection diagrams are provided, with detailed pin functions for both flanged and non-flanged packages.
Performance Curves
Efficiency curves are provided for different models at typical conditions.
Output Voltage Adjustment
The output voltage can be adjusted using the +S pin with a trim resistor, allowing up to a 10% increase from nominal. The -S pin should be connected to the OUTCOM pin.
Remote Sense
Compensates for voltage drops, allowing up to a 10% voltage drop compensation. The total compensation should not exceed 10%.
Frequency Synchronization
The converter operates at 525 kHz by default. An external clock can drive the SYNC pin for synchronization.
Protection Features
  • Input Undervoltage Lockout
  • Output Soft Start
  • Output Overcurrent Protection
Thermal Considerations
Rated for full power operation at 125 °C, with derating required above this temperature. Designed for conduction cooling.
Radiation Hardness Assurance (RHA)
Ensures performance in space environments, covering TID, ELDRS, and SEE.
Environmental Screening
Tested per MIL-STD-883 and MIL-PRF-38534 standards.
Ordering Information
Product codes specify series, input voltage, output voltage, number of outputs, package option, and screening code.
Contact Information
For quotations or orders, contact VPT, Inc. Sales Department via phone at (425) 353-3010, fax at (425) 353-4030, or email at [email protected].
Disclaimer
The datasheet information is believed accurate but not guaranteed. Specifications may change without notice.
Additional Resources
Visit the VPT website for product catalogs, application notes, white papers, technical video labs, and information on additional products for avionics, military, Hi-Rel COTS, and space applications.
See more

Catalog excerpts

SVTR2800S SERIES-1

vpr Power Your Critical Mission Today Models Available Input: 15 V to 50 V continuous, 80 V transient 40 W, single output of 3.3 V, 5 V, 8 V, 12 V, 15 V Qualified to MIL-PRF-38534 Class H and Class K 1.0 DESCRIPTION The SVTR Series of space qualified DC-DC converters is specifically designed for the harsh radiation environment of space applications. Performance is guaranteed through the use of hardened semiconductor components, radiation lot acceptance testing (RLAT) of non-hardened components, and analysis. The SVTR Series has been characterized for Total Ionizing Dose (TID) performance including Enhanced Low Dose Rate Sensitivity (ELDRS) and for Single Event Effects (SEE) according to VPT's DLA-approved Radiation Hardness Assurance (RHA) plan per MIL-PRF-38534, Appendix G, Level P. Characterization is performed at both the component level and at the SVTR Series hybrid converter level. The SVTR Series of DC-DC converters is radiation tolerant and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs. 1.1 FEATURES • Up to 40 W output power • Wide input voltage range: 15 V to 50 V plus 80 V transient • Continuous operation over full military temperature range of -55 °C to +125 °C with no power derating • Very low output noise • Output voltage trim up +10% • Radiation immune magnetic feedback circuit • No use of optoisolators • Undervoltage lockout • Current limit protection / short circuit protection 1.2 SPACE LEVEL CHARACTERIZATIONS • Guaranteed TID performance to 30 krad(Si) including ELDRS • SEE performance to 44 MeV-cm2/mg. Transients are fully characterized for cross section and magnitude • Worst-case analysis, stress, radiation, reliability reports available 1.3 MANUFACTURING AND COMPLIANCE • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD # 5962-11220 • MIL-PRF-38534 element evaluated components • MIL-STD-461 C/D/E/F when used with appropriate VPT EMI filter • Manufactured in a MIL-PRF-38534 Class H and Class K facility • MIL-STD-883 • ISO-9001 1.4 PACKAGING • Low-profile: 2.890” x 1.125” x 0.405” • Max weight: 55 g • Industry standard pinout • Precision seam-welded hermetic metal case • Flanged and Non-flanged versions available 1.5 SIMILAR PRODUCTS AND ACCESSORIES • SVTR 40 W dual output DC-DC converter • SVRTR 40 W space qualified DC-DC converter, 100 krad(Si) • Custom versions available • EMI filters • Non-isolated, space qualified point of load converters • Use with Thermal Pad TP-003

 Open the catalog to page 1
SVTR2800S SERIES-2

SVTR2800S Series 2.0 DIAGRAMS 2.1 BLOCK DIAGRAM D1 UNDER VOLTAGE SHUTDOWN PRIMARY HOUSEKEEPING SUPPLY VOLTAGE AND CURRENT AMPLIFIERS MAGNETIC FEEDBACK SECONDARY HOUSEKEEPING SUPPLY 2.2 CONNECTION DIAGRAM DVMC28 EMI FILTER 1 3.0 SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS Absolute Maximum Ratings Input Voltage (Continuous): Input Voltage (Transient, 1 second): ESD Rating per MIL-PRF-38534: Sales Information Operating Temperature (Full Load): Storage Temperature: Lead Solder Temperature (10 seconds): E-mail: [email protected]

 Open the catalog to page 2
SVTR2800S SERIES-3

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 1. Time for output voltage to settle within 1% of steady-state value 2. Verified by qualification testing 3. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 3
SVTR2800S SERIES-4

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 1. Time for output voltage to settle within 1% of steady-state value 2. Verified by qualification testing 3. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 4
SVTR2800S SERIES-5

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load, Unless Otherwise Specified Parameter Conditions Min Typ Max Units Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVTR2800S - 7.0 Page 5 Verified by qualification testing Time for output voltage to settle within 1% of steady-state value End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted

 Open the catalog to page 5
SVTR2800S SERIES-6

SVTR2800S Series 4.0 PERFORMANCE CURVES 4.1.1 SVTR283R3S Efficiency (Typical, 25 °C) Sales Information E-mail: [email protected]

 Open the catalog to page 6
SVTR2800S SERIES-7

vpr Power Your Critical Mission Today 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Ceramic) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVTR2800S - 7.0 Page 7

 Open the catalog to page 7
SVTR2800S SERIES-8

vpr Power Your Critical Mission Today 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Mounting holes are not threaded. Recommended fastener is 6-32 4. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Ceramic) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVTR2800S - 7.0 Page 8

 Open the catalog to page 8
SVTR2800S SERIES-9

SVTR2800S Series 6.0 TECHNICAL NOTES Please note that many of these functions are also demonstrated in detail on the VPT website in the form of technical video labs. 6.1 GENERAL INFORMATION 6.1.1 Topology Description The SVTR2800S Series is an isolated, single output, flyback converter. It operates over a wide input voltage range and provides a tightly regulated positive output voltage with respect to the OUTCOM pin. Feedback isolation is accomplished using VPT’s proprietary magnetic feedback technology. The converter regulates with zero load, and no minimum load is required. 6.1.2 External Components...

 Open the catalog to page 9

All VPT Inc catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.