1. Catalogs
  2. VPT Inc
  3. SVTR2800D SERIES

SVTR2800D SERIES

SVTR2800D SERIES
1 / 15 PagesView full catalog

SVTR2800D SERIES

Product catalog summary
Overview: The SVTR2800D Series comprises space-qualified hybrid DC-DC converters designed for harsh radiation environments in space applications. They are characterized for Total Ionizing Dose (TID) and Single Event Effects (SEE), suitable for various orbits and space missions.
Specifications: These converters provide dual outputs of ±5 V, ±8 V, ±12 V, and ±15 V with up to 40 W output power. They operate over an input voltage range of 15 V to 50 V, with a transient capability of 80 V, and are qualified to MIL-PRF-38534 Class H and Class K standards.
Features: Key features include operation over a military temperature range (-55 °C to +125 °C), low output noise, radiation-immune magnetic feedback, undervoltage lockout, and current limit protection. The absence of optoisolators enhances reliability in space environments.
Performance: The converters are characterized for TID performance up to 30 krad(Si) and SEE performance to 44 MeV-cm2/mg, offering high efficiency ranging from 73% to 84% depending on the model and conditions.
Mechanical and Compliance: Available in low-profile packages with flanged and non-flanged options, they are manufactured in facilities compliant with MIL-PRF-38534 and ISO-9001 standards.
Applications: Ideal for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs.
Technical Notes: Utilizing a flyback topology with magnetic feedback for voltage regulation, they operate without external components, though additional output capacitance can be added for specific ripple requirements. Configurable for dual or single-ended output applications.
Specifications and Function Descriptions: Converters can be stacked for higher voltages, e.g., two SVTR2812D converters for a 48 V output at 80 W. The On/Off Control (Inhibit) pin allows disabling the output by pulling it low. Frequency synchronization is optional via an external clock signal.
Protection Features: Include input undervoltage lockout, output soft start, and output overcurrent protection. The soft start function controls output ramp-up to prevent overshoot and limit inrush current. Overcurrent protection limits output current to 125% of its rated value.
Thermal Considerations: Rated for full power operation at 125 °C, with power derating required above this temperature. Designed for conduction cooling with heat dissipation through the baseplate.
Radiation Hardness Assurance (RHA) Plan: VPT's RHA plan ensures performance in space environments, covering TID, ELDRS, and SEE. Testing includes gamma radiation exposure and characterization for catastrophic events and functional interrupts.
Environmental Screening: Testing per MIL-STD-883 and MIL-PRF-38534 standards includes bond pull, internal visual inspection, temperature cycling, constant acceleration, and hermeticity checks.
Ordering Information: The ordering code details product series, input and output voltages, number of outputs, package options, and screening codes. Customers should contact VPT for specific requirements and additional screening options.
Contact Information: For quotations or orders, contact VPT, Inc. Sales Department via phone, fax, or email. Additional technical resources are available on the VPT website.
See more

Catalog excerpts

SVTR2800D SERIES-1

vpr Power Your Critical Mission Today Models Available Input: 15 V to 50 V continuous, 80 V transient 40 W, dual outputs of ±5 V, ±8 V, ±12 V, ±15 V Qualified to MIL-PRF-38534 Class H and Class K 1.0 DESCRIPTION The SVTR Series of space qualified DC-DC converters is specifically designed for the harsh radiation environment of space applications. Performance is guaranteed through the use of hardened semiconductor components, radiation lot acceptance testing (RLAT) of non-hardened components, and analysis. The SVTR Series has been characterized for Total Ionizing Dose (TID) performance including Enhanced Low Dose Rate Sensitivity (ELDRS) and for Single Event Effects (SEE) according to VPT's DLA-approved Radiation Hardness Assurance (RHA) plan per MIL-PRF-38534, Appendix G, Level P. Characterization is performed at both the component level and at the SVTR Series hybrid converter level. The SVTR Series of DC-DC converters is radiation tolerant and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs. 1.1 FEATURES • Up to 40 W output power • Wide input voltage range: 15 V to 50 V plus 80 V transient • Continuous operation over full military temperature range of -55 °C to +125 °C with no power derating • Very low output noise • Radiation immune magnetic feedback circuit • No use of optoisolators • Undervoltage lockout • Current limit protection / short circuit protection 1.2 SPACE LEVEL CHARACTERIZATIONS • Guaranteed TID performance to 30 krad(Si) including ELDRS • SEE performance to 44 MeV-cm2/mg. Transients are fully characterized for cross section and magnitude • Worst-case analysis, stress, radiation, reliability reports available 1.3 MANUFACTURING AND COMPLIANCE • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD # 5962-11223 • MIL-PRF-38534 element evaluated components • MIL-STD-461 C/D/E/F when used with appropriate VPT EMI filter • Manufactured in a MIL-PRF-38534 Class H and Class K facility • MIL-STD-883 • ISO-9001 1.4 PACKAGING • Low-profile: 2.890” x 1.125” x 0.405” • Max weight: 55 g • Industry standard pinout • Precision seam-welded hermetic metal case • Flanged and Non-flanged versions available 1.5 SIMILAR PRODUCTS AND ACCESSORIES • SVTR 40 W single output DC-DC converter • SVRTR 40 W space qualified DC-DC converter, 100 krad(Si) • Custom versions available • EMI filters • Non-isolated, space qualified point of load converters • Use with Thermal Pad TP-003

 Open the catalog to page 1
SVTR2800D SERIES-2

SVTR2800D Series 2.0 DIAGRAMS 2.1 BLOCK DIAGRAM D2 +VOUT C3 -VOUT INCOM Q1 MAGNETIC FEEDBACK UNDER VOLTAGE SHUTDOWN VOLTAGE AND CURRENT AMPLIFIERS PRIMARY HOUSEKEEPING SUPPLY SECONDARY HOUSEKEEPING SUPPLY 2.2 CONNECTION DIAGRAM DVMC28 EMI FILTER 1 3.0 SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS Absolute Maximum Ratings Input Voltage (Continuous): Input Voltage (Transient, 1 second): ESD Rating per MIL-PRF-38534: Sales Information Operating Temperature (Full Load): Storage Temperature: Lead Solder Temperature (10 seconds): E-mail: [email protected]

 Open the catalog to page 2
SVTR2800D SERIES-3

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 4. Verified by qualification testing 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 7. 5% Load to Full Load at -55 °C Sales Information Phone:(425) 353-3010 E-mail: [email protected] Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn from either of the two outputs Time for output voltage to settle within...

 Open the catalog to page 3
SVTR2800D SERIES-4

vpr Power Your Critical Mission Today Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 4. Verified by qualification testing 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 7. 5% Load to Full Load at -55 °C Sales Information Phone:(425) 353-3010 E-mail: [email protected] Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn from either of the two outputs Time for output voltage to settle within 1%...

 Open the catalog to page 4
SVTR2800D SERIES-5

SVTR2800D Series 4.0 PERFORMANCE CURVES Sales Information E-mail: [email protected]

 Open the catalog to page 5
SVTR2800D SERIES-6

vpr Power Your Critical Mission Today E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 6
SVTR2800D SERIES-7

vpr Power Your Critical Mission Today 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Ceramic) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVTR2800D - 7.0 Page 7

 Open the catalog to page 7
SVTR2800D SERIES-8

vpr Power Your Critical Mission Today 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Mounting holes are not threaded. Recommended fastener is 6-32 4. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Ceramic) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 8
SVTR2800D SERIES-9

SVTR2800D Series 6.0 TECHNICAL NOTES Please note that many of these functions are also demonstrated in detail on the VPT website in the form of technical video labs. 6.1 GENERAL INFORMATION 6.1.1 Topology Description The SVTR2800D Series is an isolated dual-output flyback converter. It provides a positive and negative output voltage with respect to the OUTCOM pin. Up to 70% of the total output power is available from either output. The internal voltage regulation loop actively regulates the positive output using VPT’s proprietary magnetic feedback technology. The negative output is regulated...

 Open the catalog to page 9

All VPT Inc catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.