Overview
The SVSA2800D Series comprises space-qualified hybrid DC-DC converters designed for harsh radiation environments in space applications. These converters are characterized by their Total Ionizing Dose (TID) and Single Event Effects (SEE) performance, making them suitable for various orbits and deep space missions.
Specifications
  • Input Voltage: 15 V to 50 V continuous, 80 V transient
  • Output Power: Up to 6 W with dual outputs of ±5 V, ±7 V, ±12 V, ±15 V
  • Operating Temperature: -55 °C to +125 °C
  • Radiation Tolerance: TID performance to 30 krad(Si) and SEE performance to 44 MeV-cm2/mg
  • Compliance: MIL-PRF-38534 Class H and Class K
Features
  • Wide input voltage range and continuous operation over full military temperature range
  • Low output noise and radiation immune magnetic feedback circuit
  • Undervoltage lockout and current limit protection
  • No use of optoisolators
Performance Specifications
  • Efficiency: 66% to 79% depending on the model
  • Ripple Voltage: 20 Hz to 10 MHz, 30 to 60 mVpp
  • Load Regulation: Specific mV ranges for +Vout and -Vout
  • Isolation: 500 V DC
  • Weight: 15 g
Mechanical and Pinout
The converters feature a low-profile package (1.075” x 1.075” x 0.270”) with an industry-standard pinout and a precision projection-welded hermetic metal case.
Technical Notes
The SVSA2800D Series uses an isolated dual-output flyback converter topology and can operate stand-alone without external components. Additional capacitors can reduce output ripple and noise. The converter is isolated, allowing for various output configurations, including stacking for higher voltages.
Protection Features
Input undervoltage lockout ensures the converter remains off for voltages below the turn-on threshold, minimizing current draw from the source.
Specifications and Features
The converters start when the input voltage exceeds the turn-on threshold and feature a lockout circuit for slow ramping input voltages. VPT’s magnetic feedback technology ensures a controlled startup sequence. The output soft-start function prevents voltage overshoot and limits inrush current, with an output rise time of approximately 8 ms. Overcurrent protection limits output current to 125% of its rated value, allowing the converter to handle overloads and short circuits with automatic recovery.
Thermal Considerations
The converters are rated for full power operation at 125 °C, with power derating required above this temperature. They are designed for conduction cooling, with heat dissipation through the baseplate. The maximum temperature rise from junction to case is 10 °C at full load.
Radiation Hardness Assurance (RHA)
VPT’s RHA plan ensures product performance in space environments, covering TID, enhanced low dose rate sensitivity (ELDRS), and SEE. Testing includes gamma radiation exposure and characterization for catastrophic events and functional interrupts under heavy ion exposure.
Environmental Screening
Products are tested per MIL-STD-883 and MIL-PRF-38534 standards. Tests include bond pull, internal visual inspection, temperature cycling, constant acceleration, and hermeticity. Engineering models are not compliant for flight use and are intended for characterization only.
Ordering Information
The ordering code specifies product series, input and output voltages, number of outputs, and screening codes. Customers must acknowledge that engineering models are not for flight use.
Contact Information
For quotations or orders, contact VPT, Inc. Sales Department via phone, fax, or email. Visit the VPT website for additional technical resources.
See more

Catalog excerpts

SVSA2800D SERIES-1

vpr Power Your Critical Mission Today Models Available Input: 15 V to 50 V continuous, 80 V transient 6 W, dual outputs of ±5 V, ±7 V, ±12 V, ±15 V Qualified to MIL-PRF-38534 Class H and Class K 1.0 DESCRIPTION The SVSA Series of space qualified DC-DC converters is specifically designed for the harsh radiation environment of space applications. Performance is guaranteed through the use of hardened semiconductor components, radiation lot acceptance testing (RLAT) of non-hardened components, and analysis. The SVSA Series has been characterized for Total Ionizing Dose (TID) performance including Enhanced Low Dose Rate Sensitivity (ELDRS) and for Single Event Effects (SEE) according to VPT's DLA-approved Radiation Hardness Assurance (RHA) plan per MIL-PRF-38534, Appendix G, Level P. Characterization is performed at both the component level and at the SVSA Series hybrid converter level. The SVSA Series of DC-DC converters is radiation tolerant and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs. 1.1 FEATURES • Up to 6 W output power • Wide input voltage range: 15 V to 50 V plus 80 V transient • Continuous operation over full military temperature range of -55 °C to +125 °C with no power derating • Very low output noise • Radiation immune magnetic feedback circuit • No use of optoisolators • Undervoltage lockout • Current limit protection / short circuit protection 1.2 SPACE LEVEL CHARACTERIZATIONS • Guaranteed TID performance to 30 krad(Si) including ELDRS • SEE performance to 44 MeV-cm2/mg. Transients are fully characterized for cross section and magnitude • Worst-case analysis, stress, radiation, reliability reports available 1.3 MANUFACTURING AND COMPLIANCE • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD # 5962-11216 • MIL-PRF-38534 element evaluated components • MIL-STD-461 C/D/E/F when used with appropriate VPT EMI filter • Manufactured in a MIL-PRF-38534 Class H and Class K facility • MIL-STD-883 • ISO-9001 1.4 PACKAGING • Low-profile: 1.075” x 1.075” x 0.270” • Max weight: 15 g • Industry standard pinout • Precision projection-welded hermetic metal case 1.5 SIMILAR PRODUCTS AND ACCESSORIES • SVSA 6 W single output DC-DC converter • Custom versions available • EMI filters • Non-isolated, space qualified point of load converters • Use with Thermal Pad TP-005

 Open the catalog to page 1
SVSA2800D SERIES-2

SVSA2800D Series 2.0 DIAGRAMS 2.1 BLOCK DIAGRAM D2 +V OUT C3 UNDER VOLTAGE SHUTDOWN PRIMARY HOUSEKEEPING SUPPLY VOLTAGE AND CURRENT AMPLIFIERS MAGNETIC FEEDBACK SECONDARY HOUSEKEEPING SUPPLY 2.2 CONNECTION DIAGRAM DVMA28 EMI FILTER 1 3.0 SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS Absolute Maximum Ratings Input Voltage (Continuous): Input Voltage (Transient, 1 second): ESD Rating per MIL-PRF-38534: Sales Information Operating Temperature (Full Load): Storage Temperature: Lead Solder Temperature (10 seconds):

 Open the catalog to page 2
SVSA2800D SERIES-3

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 6. 5% Load to full load at -55 °C Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com 1 Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn from either of the two outputs. Time for output voltage to settle...

 Open the catalog to page 3
SVSA2800D SERIES-4

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 6. 5% Load to full load at -55 °C Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com 1 Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn from either of the two outputs. Time for output voltage to settle...

 Open the catalog to page 4
SVSA2800D SERIES-5

vpr Power Your Critical Mission Today O- E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 5
SVSA2800D SERIES-6

vpr Power Your Critical Mission Today O- E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 6
SVSA2800D SERIES-7

vpr Power Your Critical Mission Today O- BASEPLATE SURFACE7X SEAL 0.070in±0.002 1.78mm±0.05 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Steel, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Glass) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVSA2800D - 8.0 Page 7

 Open the catalog to page 7
SVSA2800D SERIES-8

SVSA2800D Series 6.0 TECHNICAL NOTES Please note that many of these functions are also demonstrated in detail on the VPT website in the form of technical video labs. 6.1 GENERAL INFORMATION 6.1.1 Topology Description The SVSA2800D Series is an isolated dual-output flyback converter. It provides a positive and negative output voltage with respect to the OUTCOM pin. Up to 70% of the total output power is available from either output. The internal voltage regulation loop actively regulates the positive output using VPT’s proprietary magnetic feedback technology. The negative output is regulated...

 Open the catalog to page 8
SVSA2800D SERIES-9

SVSA2800D Series 6.3 PROTECTION FEATURES 6.3.1 Input Undervoltage Lockout The SVSA2800D Series provides input undervoltage lockout protection. For input voltages below the turn-on voltage, the converter will remain off, drawing minimal current from the source. When the input voltage exceeds the turn-on voltage, the converter will start. The lockout circuit is designed to tolerate slow ramping input voltage waveforms. VPT’s proprietary magnetic feedback technology provides bias voltage to all secondary control circuits and control amplifiers before the output starts, ensuring a well-controlled...