Overview: The SVHF2800D Series consists of space-qualified hybrid DC-DC converters designed for harsh radiation environments in space applications. They are characterized for Total Ionizing Dose (TID) and Single Event Effects (SEE) performance, making them suitable for various orbits and deep space missions.
Specifications: These converters provide dual outputs of ±5 V, ±12 V, and ±15 V with up to 20 W output power. They operate over an input voltage range of 15 V to 50 V, with a transient capability of 80 V, and are qualified to MIL-PRF-38534 Class H and Class K standards.
Features: Key features include operation over a temperature range of -55 °C to +125 °C, low output noise, radiation-immune magnetic feedback, undervoltage lockout, and current limit protection. The absence of optoisolators enhances reliability in space environments.
Performance Specifications: Efficiency ranges from 73% to 85% depending on the model and conditions. The converters handle ripple currents and voltages effectively, with specific limits on line and load regulation, and feature cross-regulation capabilities for balanced and unbalanced load conditions.
Mechanical and Compliance: Housed in a low-profile, hermetic metal case, the converters offer flanged and non-flanged packages and comply with military and quality standards, including MIL-STD-461 and ISO-9001.
Technical Notes: Utilizing an isolated dual-output flyback topology with magnetic feedback for voltage regulation, the converters can operate standalone without external components, though additional capacitors can reduce output ripple further. They handle high source impedance and can be configured for single-ended or dual-output applications.
Protection Features: Includes input undervoltage lockout to prevent operation below specified input voltages, ensuring minimal current draw when inactive.
Output Soft Start: Features an output soft-start function for controlled ramp-up of output voltage, preventing overshoot and limiting inrush current, with a rise time of approximately 8 ms.
Output Overcurrent Protection: Provides protection against overcurrent and short circuits, limiting output current to 125% of its rated value and maintaining constant current during overloads for automatic recovery once the fault is removed.
Thermal Considerations: Operates at full power up to 125°C, with power derating required above this temperature, designed for conduction cooling with heat dissipation through the baseplate.
Radiation Hardness Assurance (RHA) Plan: VPT's RHA plan ensures product performance in space environments, covering TID, ELDRS, and SEE, with testing including gamma radiation exposure and characterization for catastrophic events and functional interrupts.
Environmental Screening: Products are tested per MIL-STD-883 and MIL-PRF-38534 standards, including bond pull, internal visual, temperature cycling, and burn-in tests to ensure reliability.
Standard Microcircuit Drawing (SMD) Numbers: Lists SMD numbers for the SVHF2800D Series, providing reference for specifications and compliance with MIL-PRF-38534 standards.
Ordering Information: Details the product series, input/output voltage options, package options, and screening codes, advising customers to contact sales for specific requirements.
Contact Information: Provides contact details for VPT, Inc. for quotations and orders, noting that product specifications are subject to change.
See more

Catalog excerpts

SVHF2800D SERIES-1

vpr Power Your Critical Mission Today Models Available Input: 15 V to 50 V continuous, 80 V transient 20 W, dual outputs of ±5 V, ±12 V, ±15 V Qualified to MIL-PRF-38534 Class H and Class K 1.0 DESCRIPTION The SVHF Series of space qualified DC-DC converters is specifically designed for the harsh radiation environment of space applications. Performance is guaranteed through the use of hardened semiconductor components, radiation lot acceptance testing (RLAT) of non-hardened components, and analysis. The SVHF Series has been characterized for Total Ionizing Dose (TID) performance including Enhanced Low Dose Rate Sensitivity (ELDRS) and for Single Event Effects (SEE) according to VPT's DLA-approved Radiation Hardness Assurance (RHA) plan per MIL-PRF-38534, Appendix G, Level P. Characterization is performed at both the component level and at the SVHF Series hybrid converter level. The SVHF Series of DC-DC converters is radiation tolerant and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs. 1.1 FEATURES • Up to 20 W output power • Wide input voltage range: 15 V to 50 V plus 80 V transient • Continuous operation over full military temperature range of -55 °C to +125 °C with no power derating • Very low output noise • Radiation immune magnetic feedback circuit • No use of optoisolators • Undervoltage lockout • Current limit protection / short circuit protection 1.2 SPACE LEVEL CHARACTERIZATIONS • Guaranteed TID performance to 30 krad(Si) including ELDRS • SEE performance to 44 MeV-cm2/mg. Transients are fully characterized for cross section and magnitude • Worst-case analysis, stress, radiation, reliability reports available 1.3 MANUFACTURING AND COMPLIANCE • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD # 5962-11215 • MIL-PRF-38534 element evaluated components • MIL-STD-461 C/D/E/F when used with appropriate VPT EMI filter • Manufactured in a MIL-PRF-38534 Class H and Class K facility • MIL-STD-883 • ISO-9001 1.4 PACKAGING • Low-profile: 2.000” x 1.130” x 0.355” • Max weight: 28 g • Industry standard pinout • Precision projection-welded hermetic metal case • Flanged and Non-flanged versions available 1.5 SIMILAR PRODUCTS AND ACCESSORIES • SVHF 20 W single output DC-DC converter • SVRHF 15 W space qualified DC-DC converter, 100 krad(Si) • Custom versions available • EMI filters • Non-isolated, space qualified point of load converters • Use with Thermal Pad TP-002

 Open the catalog to page 1
SVHF2800D SERIES-2

SVHF2800D Series 2.0 DIAGRAMS 2.1 BLOCK DIAGRAM D2 +V OUT C3 UNDER VOLTAGE SHUTDOWN PRIMARY HOUSEKEEPING SUPPLY VOLTAGE AND CURRENT AMPLIFIERS MAGNETIC FEEDBACK SECONDARY HOUSEKEEPING SUPPLY 2.2 CONNECTION DIAGRAM DVMH28 EMI FILTER 1 3.0 SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS Absolute Maximum Ratings Input Voltage (Continuous): Input Voltage (Transient, 1 second): ESD Rating per MIL-PRF-38534: Sales Information Operating Temperature (Full Load): Storage Temperature: Lead Solder Temperature (10 seconds): E-mail: [email protected]

 Open the catalog to page 2
SVHF2800D SERIES-3

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Min Typ Max Units 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 6. 5% load to full load at -55 °C Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com 1 Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn either of the two outputs Time for output voltage to settle within...

 Open the catalog to page 3
SVHF2800D SERIES-4

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +28 V ± 5%, Full Load1, Unless Otherwise Specified Parameter Conditions Min Typ Max Units 5. End-of-Life performance includes aging and radiation degradation and is within standard limits except where noted 6. 5% load to full load @ -55 °C Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVHF2800D - 5.0 Page 4 Half load at +Vout and half load at -Vout Up to 70% of the total power or current can be drawn from either of the two outputs. Time for output voltage to...

 Open the catalog to page 4
SVHF2800D SERIES-5

SVHF2800D Series 4.0 PERFORMANCE CURVES 4.1.1 SVHF2805D Efficiency (Typical, 25 °C) Sales Information E-mail: [email protected]

 Open the catalog to page 5
SVHF2800D SERIES-6

SVHF2800D Series 4.0 PERFORMANCE CURVES (CONTINUED) 4.2.1 SVHF2805D Cross-Regulation (Typical, 25 °C) Sales Information E-mail: [email protected]

 Open the catalog to page 6
SVHF2800D SERIES-7

vpr Power Your Critical Mission Today O- 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Steel, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Glass) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVHF2800D - 5.0 Page 7

 Open the catalog to page 7
SVHF2800D SERIES-8

vpr Power Your Critical Mission Today O- 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Mounting holes are not threaded. Recommended fastener is # 4-40 screw 4. Materials: Case (Steel, gold over nickel plated); Cover (Steel, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Glass) Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 8
SVHF2800D SERIES-9

SVHF2800D Series 6.0 TECHNICAL NOTES Please note that many of these functions are also demonstrated in detail on the VPT website in the form of technical video labs. 6.1 GENERAL INFORMATION 6.1.1 Topology Description The SVHF2800D Series is an isolated dual-output flyback converter. It provides a positive and negative output voltage with respect to the OUTCOM pin. Up to 70% of the total output power is available from either output. The internal voltage regulation loop actively regulates the positive output using VPT’s proprietary magnetic feedback technology. The negative output is regulated...