Overview: The SVFA0510SG series is a space-qualified point of load DC-DC converter designed for harsh radiation environments in space applications. It is suitable for various space missions including low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicles.
Specifications:
  • Input Voltage: 5V nominal
  • Output: Adjustable from 0.8V to 3.4V, up to 10 Amps
  • Efficiency: Up to 94%
  • Power Density: Up to 100 W/in3
  • Radiation Tolerance: TID performance to 40 krad(Si) and SEE performance to 85 MeV/mg/cm2
Features:
  • High efficiency and power density
  • Output inhibit control and low output noise
  • Short circuit protection
  • No use of optoisolators
Manufacturing and Compliance:
  • Qualified to MIL-PRF-38534 Class H and Class K
  • Manufactured in a MIL-PRF-38534 Class H and Class K facility
  • Complies with MIL-STD-883 and ISO-9001 standards
Mechanical and Packaging:
  • Dimensions: 1.110” x 1.110” x 0.276”
  • Weight: Max 22g
  • Hermetic metal case
Performance Specifications:
  • Operating Temperature: -55°C to +125°C
  • Input Voltage Range: 3.5V to 7V
  • Output Voltage Regulation: ±1.5% over temperature range
  • Ripple Voltage: 60-100 mVpp
Protection Features:
  • Input undervoltage lockout
  • Output soft-start to prevent overshoot and limit inrush current
  • Output short circuit protection with hiccup mode
Technical Notes:
  • Topology: Non-isolated, fixed-frequency, synchronous buck converter
  • External Components: Requires additional 100 µF tantalum input decoupling capacitor
  • Source Impedance: High source impedance may require additional input capacitance
Thermal Considerations: The converter is designed for full power operation at temperatures up to 125°C, with output power reduced linearly to zero at 135°C. It is conduction-cooled, with heat dissipated through the baseplate.
Radiation Hardness Assurance: VPT ensures product performance through a conservative radiation testing approach, including TID, SEE, and ELDRS testing.
Environmental Screening: The series undergoes 100% testing per MIL-STD-883, with options for additional screening.
Standard Microcircuit Drawing (SMD) Numbers: SMD numbers are available with RHA level P, with specifications on the DLA Land and Maritime website.
Ordering Information: The ordering code includes product series, nominal input voltage, output current, number of outputs, package options, and screening codes. Contact VPT Sales for more options.
Contact Information: For quotations or orders, contact VPT, Inc. Sales Department via phone, fax, or email. Datasheet information is subject to change without notice.
Additional Information: Visit the VPT website for more technical resources, including product catalogs, application notes, and technical videos.
See more

Catalog excerpts

SVFA0510SG SERIES-1

vpr Power Your Critical Mission Today SPACE QUALIFIED POINT OF LOAD CONVERTERS Models Available Input: 5V Nominal 10 A output Qualified to MIL-PRF-38534 Class H and Class K 1.0 DESCRIPTION The SVFA Series of space qualified point of load DC-DC converters is specifically designed for the harsh radiation environment of space applications. Performance is guaranteed through the use of hardened semiconductor components, radiation lot acceptance testing (RLAT) of non-hardened components, and analysis. The SVFA Series has been characterized for Total Ionizing Dose (TID) performance including Enhanced Low Dose Rate Sensitivity (ELDRS) and for Single Event Effects (SEE) according to VPT’s DLA-approved Radiation Hardness Assurance (RHA) plan per MIL-PRF-38534, Appendix G, Level P. Characterization is performed at both the component level and at the SVFA hybrid converter level. The SVFA Series of point of load DC-DC converters is radiation tolerant and suited for use in low Earth orbit (LEO), medium Earth orbit (MEO), geostationary orbit (GEO), deep space, and launch vehicle programs. 1.1 FEATURES • Operates from 5 V input • Adjustable Output from 0.8 to 3.4V • Up to 10 Amps Output • High Efficiency, up to 94% • High Power Density, up to 100 W/in3 • Output Inhibit Control • Low Output Noise • No Use of Optoisolators • Short Circuit Protection 1.2 SPACE LEVEL CHARACTERIZATIONS • Guaranteed TID performance to 40 krad(Si) including ELDRS. • SEE performance to 85 MeV/mg/cm2. Transients are fully characterized for cross section and magnitude. • Worst-case analysis, stress, radiation, reliability reports available 1.3 MANUFACTURING AND COMPLIANCE • Qualified to MIL-PRF-38534 Class H and Class K, DLA SMD # 5962-17203 • MIL-PRF-38534 element evaluated components • Manufactured in a MIL-PRF-38534 Class H and Class K facility • MIL-STD-883 • ISO-9001 1.4 PACKAGING • Low-profile: 1.110” x 1.110” x 0.276” • Max weight: 22 g • Precision seam-sealed hermetic metal case 1.5 SIMILAR PRODUCTS AND ACCESSORIES • SVFA0510S 10 A space qualified point of load DC-DC converter • SVFA0515S 15 A space qualified point of load DC-DC converter • SVFA0515SG 15 A space qualified point of load DC-DC converter • SVGA0510SG 10 A space qualified point of load DC-DC converter • SVGA0515SG 15 A space qualified point of load DC-DC converter • SVRGA0508S 8 A space qualified point of load DC-DC converter • Custom versions available • Space qualified isolated DC-DC converters. 6 - 100 W • EMI filters

 Open the catalog to page 1
SVFA0510SG SERIES-2

vpr Power Your Critical Mission Today O- 1. Rtrim should be connected directly across pins 11 and 12 as close as possible to the SVFA. 2. AGND should be connected to GND close to the SVFA. Voltage difference between the AGND and the GND pins greater than 0.3 V may result in regulation error and/or damage to the SVFA. 3. If not using INH, leave pin 9 open. 4. Rcomp and Ccomp are optional components that can be used to optimize the SVFA transient response. 3.0 SPECIFICATIONS 3.1 ABSOLUTE MAXIMUM RATINGS

 Open the catalog to page 2
SVFA0510SG SERIES-3

vpr Power Your Critical Mission Today O- Tcase = -55 °C to +125 °C, Vin = +5 V ± 1%, Full Load, Unless Otherwise Specified Sales Information Phone:(425) 353-3010 Fax: (425) 353-4030E-mail: [email protected] Web: www.vptpower.com SVFA0510SG - 5.0 Page 3 Performance specifications are guaranteed with 100gF from VIN to GND. Verified by initial electrical design verification. Post design verification, parameter shall be guaranteed to the limits specified. Output voltage not necessarily in regulation. Dependent on output voltage. Time for output voltage to settle within 1% of steady-state value....

 Open the catalog to page 3
SVFA0510SG SERIES-4

vpr Power Your Critical Mission Today O- Output Current E-mail: [email protected] Web: www.vptpower.com

 Open the catalog to page 4
SVFA0510SG SERIES-5

SVFA0510SG Series 5.0 MECHANICAL OUTLINES AND PINOUT Standard Package Option: 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated, 63/37 SnPb solder dipped); Pin Seals (Glass) Sales Information E-mail: [email protected]

 Open the catalog to page 5
SVFA0510SG SERIES-6

vpr Power Your Critical Mission Today o- SVFA0510SG Series5.0 MECHANICAL OUTLINES AND PINOUT (CONTINUED)Optional Straight-Lead Package: 2.41Q±.010 61.21±025 | 1.11 Oin 128.19mm 1. Tolerances are +0.005” unless otherwise stated 2. Case temperature is measured on the center of the baseplate surface 3. Materials: Case (Steel, gold over nickel plated); Cover (Kovar, nickel plated); Pin (Copper-cored alloy 52, gold over nickel plated); Pin Seals (Glass) 4. Pins may have exposed nickel plating (not base metal) beyond the ceramic tie bars due to the plating process. No nickel plating is exposed between...

 Open the catalog to page 6
SVFA0510SG SERIES-7

SVFA0510SG Series 6.0 TECHNICAL NOTES Please note that many of these functions are also demonstrated in detail on the VPT website in the form of technical video labs. 6.1 GENERAL INFORMATION 6.1.1 Topology Description The SVFA0510SG is a non-isolated, fixed-frequency, radiation-hardened, synchronous buck converter. It operates from a 5 V input and provides a stepped-down, precisely regulated, programmable output voltage at high efficiency. The SVFA0510SG is optimized for low voltage point-of-load (POL) applications. 6.1.2 External Components The SVFA0510SG Series has internal input and output...

 Open the catalog to page 7
SVFA0510SG SERIES-8

SVFA0510SG Series 6.2.2 Adjusting the Output Voltage (TRIM) The output voltage of the converter is set with an external resistor connected from the TRIM pin to the AGND pin. Use the equations or table below to choose the trim resistor value. Trim resistor tolerance of 0.1% is recommended to achieve an accurate output voltage. The default output voltage with the TRIM pin left open is 0.8 V. SVFA0510SG ݑŰݑ Űݑpݑpݑpݑpݑpݑ pݑpݑ = pݑɰݑɰݑ°ݑ°ݑ°ݑ°ݑ°ݑ = 6.2.3 Output Capacitors Output capacitors for point-of-load (POL) DC/DC converters should be chosen to meet output voltage ripple and transient requirements....

 Open the catalog to page 8

All VPT Inc catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.