This document introduces the Standard Series of High Purity Nitrogen Generators, models NG4HP through NG50HP, provided by Vortex Compressor, based in Ankara, Turkey.
The document appears to be an introductory or cover page for a technical brochure or manual related to nitrogen generators designed to produce high purity nitrogen gas. The series covers multiple models, likely differentiated by capacity or output purity, though specific technical specifications, operational procedures, standards, or recommendations are not included in the provided text.
For detailed specifications, operational guidelines, or technical data, the reader is directed to visit the company website or contact the company directly.
NITROGEN GENERATORS STANDART SERIES High Purity (NG4HP-NG50HP) The economical, reliable and user-friendly solution for nitrogen gas needs. VORTEX nitrogen generators produce nitrogen gas from compressed air and offer a cost- effective, reliable and safe alternative to traditional nitrogen gas supplies such as cylinder or liquid. Nitrogen is used as a clean, dry, inert gas primarily for removing oxygen from products and/or processes. VORTEX nitrogen generator provides an on-demand, continuous source of nitrogen gas which can be used in a wide range of industries such as food, beverage, laboratory, chemical, electronics, transportation and oil and gas. Swing Adsorption) principle □ Simple operator interface □ Best quality robust components D High nitrogen purities (up to %99.999) can be achieved economically D High efficiency (high nitrogen to air ratio), which means low nitrogen cost D No unnecessary electronics that complicate to use and maintain D Years of uninterrupted service For more information please visit www.vortexcompressor.com
Open the catalog to page 1NITROGEN GENERATORS STANDART SERIES High Purity (NG4HP-NG50HP) Technical Data □ Nitrogen supply pressure Pressure Swing Adsorption About 1,5 bar less than air supply pressure (maximum 8 bar) 230 VAC (Other voltages optional) Negligible (less than 300W) Should be installed in a covered and well-ventilated area +5/+40°C 8,5 bar (It can work at pressures down to 5.5 bar but with lower capacity) maximum 30°C Standard Instrumentation □ Oxygen content is continuously measured and displayed. □ If oxygen content is higher than a user programmable preset value, then generated nitrogen is diverted to waste...
Open the catalog to page 22 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
14 Pages