Volt Elektrik Motor - catalog
106Pages

{{requestButtons}}

Catalog excerpts

Volt Elektrik Motor - catalog - 2

Volt Motors is a subsidiary of the Saya Group, a privately held Turkish conglomerate with interests in real estate development, tooling and molding, pharmaceuticals, mining and low-voltage industrial motor manufacturing. We manufacture the highest quality electric motors, designed and produced in a modern facility utilizing highly trained personnel and the latest manufacturing equipment. We not only operate cost efficiently but also in an environmentally responsible manner. Our recent expansion into international markets has led to a new management philosophy based on international...

Open the catalog to page 2
Volt Elektrik Motor - catalog - 3

EFFICIENCY CLASSIFICATION in LOW-VOLTAGE MOTORS ACCORDING TO IEC 60034-30 APPLICATION CALENDAR EFFICIENCY CLASS TABLES ACCORDING TO IEC 60034-30 (50 Hz) EFFICIENCY CLASS TABLES ACCORDING TO IEC 60034-30 (60 Hz) ASYNCHRONOUS MOTOR LOSSES DUTY TYPES PROTECTION CLASSES MAIN COOLING TYPES ACCORDING TO IEC 60034-6 CONSTRUCTION FORMATS and INSTALLATION SYSTEMS STANDARD ROTATION DIRECTION CONNECTIONS and TERMINAL MARKINGS OF ASYNCHRONOUS MOTORS SURFACE SOUND PRESSURE LEVEL LpA dB(A) SOUND POWER LEVEL LWA (dB) AT UNLOADED OPERATION ACCORDING TO IEC 60034-9 SOUND POWER LEVEL LWA (dB) AT RATED POWER...

Open the catalog to page 3
Volt Elektrik Motor - catalog - 4

EFF2 (IE1) HIGH EFFICIENCY ASYNCHRONOUS THREE PHASE MOTORS – 400 V / 50 Hz, 4 POLES EFF2 (IE1) HIGH EFFICIENCY ASYNCHRONOUS THREE-PHASE MOTORS – 380 V / 50 Hz, 400 V / 50 Hz, 6 POLES EFF2 (IE1) HIGH EFFICIENCY ASYNCHRONOUS THREE PHASE MOTORS – 400 V / 50 Hz, 6 POLES 58 ELECTRICAL PERFORMANCE VALUES: TWO-SPEED 60 GENERAL PURPOSE MOTORS (THREE-PHASE TWO-SPEED ASYNCHRONOUS MOTORS (Dahlander WINDING)) ASYNCHRONOUS THREE-PHASE TWO-SPEED (Dahlander CIRCUIT) MOTORS, 4/2 POLES ASYNCHRONOUS THREE-PHASE TWO-SPEED (Dahlander CIRCUIT) MOTORS, 8/4 POLES ASYNCHRONOUS THREE-PHASE TWO WINDINGS TWO-SPEED...

Open the catalog to page 4
Volt Elektrik Motor - catalog - 6

Aluminum and cast iron frames are between 63-315, 0,12 kW - 200 kW. (Aluminum frame: 63 – 180. Cast iron frame: 160-315). Their manufacturing and installation systems are IM B3, IM B5, IM B14 and B3/B5 (B35) and B3/B14 (B34) combined system format according to IEC 60034-7. Motors can also operate in vertical and appropriate installation positions. motors up to 2,2 kW are 230 230VD/400VY 50 Hz. The voltages and frequencies for 2 and 4-pole, threephase motors over 3 kW and 6-pole, three-phase motors over 2,2 kW are 400 VD/690VY 50 Hz. Terminal boxes are made from aluminum alloy for...

Open the catalog to page 6
Volt Elektrik Motor - catalog - 9

STANDARDS and RECOMMENDATIONS Standard No. Standard Methods for Determining Losses and Efficiency from Tests Specific Methods for Determining Separate Losses of Large Machines from Tests - Supplement to IEC 60034-2-1 Protection Level (IP Code) Cooling Method (IC Code) Construction Type and Installation System (IM Code) Marking of Connection Terminals and Rotation Direction Noise Limits Thermal Protection Classes Starting Performance Mechanical Vibration Measurement and Limitations Three-phase Caged Induction Motors Efficiency Classes Three-phase Induction Motors Construction Sizes Letter...

Open the catalog to page 9
Volt Elektrik Motor - catalog - 10

EFFICIENCY CLASSIFICATION in LOW-VOLTAGE MOTORS ACCORDING TO IEC 60034-30 APPLICATION CALENDAR Efficiency application calendar shall be applied as in Figure . IEC/EN 60034-34 has been published by IEC in October of 2008. Its purpose is to eliminate the numerous different energy standards used for cage-induction motors and to create a single description for low-voltage motors efficiencies to be used globally. These efficiency classes are: • Premium efficiency IE3 • High efficiency IE2 • Standard efficiency IE1 IE4 class was defined in IEC 60034-30:2008 for asynchronous and synchronous...

Open the catalog to page 10
Volt Elektrik Motor - catalog - 11

EFFICIENCY CLASS TABLES ACCORDING TO IEC 60034-30 (50 Hz) TABLE 2: Efficiency class and values according to IEC 60034-30 (50Hz) (50 HZ) 2 POLES ASYNCHRONOUS MOTOR EFFICIENCY GRAPH PN = MOTOR OUTPUT POWER (kW) FIGURE 3: 2 poles Asynchronous motor efficiency power chart (50 Hz) (50 Hz) 6 POLES ASYNCHRONOUS MOTOR EFFICIENCY GRAPH P„ = MOTOR OUTPUT POWER (kW) FIGURE 5: 6 poles Asynchronous motor efficiency power chart (50 Hz) (50 Hz) 4 POLES ASYNCHRONOUS MOTOR EFFICIENCY GRAPH P„ = MOTOR OUTPUT POWER (kW) FIGURE 4: 4 poles Asynchronous motor efficiency power chart (50 Hz)

Open the catalog to page 11
Volt Elektrik Motor - catalog - 12

EFFICIENCY CLASS TABLES ACCORDING TO IEC 60034-30 (60 Hz) MOTOR POWER kW FIGURE 6: 6 poles Asynchronous motor efficiency power chart (60Hz) FIGURE 7: 4 poles Asynchronous motor efficiency power chart (60Hz) TABLE 3: Efficiency class tables according to IEC 60034-30 (60Hz) FIGURE 8: 2 poles Asynchronous motor efficiency power chart (60Hz)

Open the catalog to page 12
Volt Elektrik Motor - catalog - 13

ASYNCHRONOUS MOTOR LOSSES FIGURE 9: Asynchronous Motor Losses Motor efficiency was calculated based on the previous EN/IEC 60034-2-1996 standard using the following methods: • Direct method • Indirect method • PLL (additional losses) is considered as 0,5% of motor input power Resistance losses in stator and rotor winding and wound rotor motors are defined according to 95°C temperature. Motor efficiency calculation according to the new IEC/ EN 60034-2-1-2007 standard is calculated as follows: • Direct method • Indirect method • PLL (additional losses) is calculated with three separate...

Open the catalog to page 13
Volt Elektrik Motor - catalog - 14

DUTY TYPES Continuous running duty Short time duty Motor operates under fixed load until reaching heat balance. Without indications of the type of rated motor, S1 continuous running duty should be assumed. This is used in pump, fan, ventilation, and compressor applications. Motor operates under fixed load without reaching the heat balance. Motor cools down to ambient temperature in stop times. Operation time is recommended as 10, 30, 60 and 90 minutes. Dam covers, sirens and some cranes can be seen as examples of application. FIGURE 10: S-1 DUTY TYPE - Continuous running duty Intermittent...

Open the catalog to page 14
Volt Elektrik Motor - catalog - 15

PROTECTION CLASSES IP according to the IEC 60034-5 standard, protecting them against dust and squirting liquids. Our standard motors are manufactured in IP 55 protection class. IP56, IP65 and IP66 are available upon request. As shown in Table 4, the first digit in the IP (Ingress Progress) First Number Second Number Protection against objects greater than 50 mm Protection against water coming vertically Protection against objects greater than 12 mm Protection against water coming vertically up to 15 ° angle Protection against objects greater than 2.5 mm Protection against water coming...

Open the catalog to page 15