Contact Gauges VBM
2Pages

{{requestButtons}}

Catalog excerpts

Contact Gauges VBM - 1

STRIP THICKNESS CONTACT GAUGES VBM Metal strip Two transducers contact the upper and lower side of the strip, the sum of the individual measurements is the absolute strip thickness. In complex measuring heads, in some cases with cardanic suspension, integrated heaters, pivot bearings and many other functions. This simple measurement principle is transformed into a high-precision measuring machine that reliably measures the strip thickness in the mill even at high strip speeds. Direct, absolute measurement irrespective of the alloy Precision up to one micrometer per millimeter of strip thickness Correct results even with oiled strip

Open the catalog to page 1
Contact Gauges VBM - 2

TYPE SERIES PROCESS PARAMETERS Material to be measured metal strip Maximal strip temperature Maximal strip speed 120 °C (up to 200 °C with reduced accuracy) 500 0.1 – 4.0 (up to 9.0 with reduced accuracy) Measurement throat depth (- 20 mm = max. measurement depth) Maximal pass line variation during measurement strip guiding rolls for fixing the pass line within the scope of supply MEASUREMENT PARAMETERS Measurement range Measurement resolution Measurement accuracy Ti ≥ 10 ms, measurement insert material: diamond, ambient temperature > 18 °C, at strip temperatures > 40 °C only with gauge...