IDS HIGH-LEIT An open and scalable SCADA system for all infrastructure applications

Open the catalog to page 1
Flyer HIGH-LEIT - 2

The IDS HIGH-LEIT SCADA system The HIGH-LEIT SCADA system is designed for applications of energy and water supply, for sewerage and environmental areas as well as for industrial requirements. The system offers – independently from hardware platform and operating system used – user friendly solutions for all tasks of process visualization, monitoring, control and automation. Areas of Application The use of modern control systems promotes economical management of operations, achieves high reliability and flexibility, and reduces capital outlay and operational costs. HIGH-LEIT was designed...

Open the catalog to page 2
Flyer HIGH-LEIT - 3

Server Level The available hardware platforms for the server level include high end PC-based systems. Microsoft Windows and Linux operating systems are supported. Dedicated function servers e.g. for database applications, simulation and training tasks and high-level optimizations, can be integrated into the control system. Where desired other LANs are hooked up to the SCADA system network via routing devices. It is thus possible to make the SCADA system’s data available to external database software, as well as to retrieve data from external databases (e.g. SQL interfaces). Remote access...

Open the catalog to page 3
Flyer HIGH-LEIT - 4

User-friendly Interface User Interface The HIGH-LEIT user interface is integrated into the standardized graphical interface of the operating system. In addition to windowing, the software supports a system interface with overlapping screens (multiscreening). All presentations and dialogs are selected and manipulated via icons and pull-down menus. The system allows the user to call up context sensitive help at any time, which provides all information necessary for system operation. Visualization of all process information is accomplished by system diagrams which can be freely configured by...

Open the catalog to page 4
Flyer HIGH-LEIT - 5

Remote zooming with navigation window in a georeferenced world map User interface with context-sensitive help instructions Display with archive graphics Object-oriented Parameterization electrical network. Alternatively, easy-to-use input dialogs are also available for conventionally configuring the system. HIGH-LEIT supports object-oriented configuration. Systems, subsystems and resources can be created, copied and deleted in accordance with logical level. The entire system hierarchy is clearly presented in the HIGH-LEIT navigator and can be processed in connection with the display editor....

Open the catalog to page 5
Flyer HIGH-LEIT - 6

SCADA Functions PROCESS Alarm module: Emergency service according to standby timetable/ alarm processing instruction dialog system/menu control horn mosaic mimic panel mobile phone/SMS telephone/sythesized voice E-Mail facsimile pager SCADA Functions HIGH-LEIT SCADA functions go far beyond basic processing of monitored binary information, measured values, counter values, switching commands and setpoints. Extensive consistency and plausibility checks and complex logical or arithmetical computations make process control easier. The process variables can be archived over a long period of time,...

Open the catalog to page 6
Flyer HIGH-LEIT - 7

Sophisticated Applications Electricity HIGH-LEIT in the electricity sector offers for topological presentation, in addition to the basic functions, various ground fault and short-circuit search strategies for meshed or branched networks as well as schematic representation of lines for overview diagrams – a unique feature. It is possible to snapshot a process image copy at any one time for later recall. A further topology function provides for network provisional arrangements. These involve time restricted network changes which are input directly and without generating action into the...

Open the catalog to page 7
Flyer HIGH-LEIT - 8

Advanced Management Functions Gas Heating For gas supply applications, HIGH-LEIT provides extensive functionality for forecasting gas output. In addition to two adaptive mathematical forecast algorithms and the prognosis with neuronal networks, the system can incorporate a climate database for long-term archiving of reference days. HIGH-LEIT optimally controls heat generation and heating/power stations as required. All local PLC parameters can be adapted throughout the control system. Requests from other sectors (e.g. where generating power has priority) are automatically taken into...

Open the catalog to page 8
Flyer HIGH-LEIT - 9

Water In addition to the detection and monitoring of leaks and low levels, HIGH-LEIT provides algorithms for water demand forecasts. Based upon predicted demand as well as available reserve capacity in purified water tanks, the use of on-demand pumps can be optimized. Moreover, procedures for optimum control of mixing water are also provided. Environmental Technology HIGH-LEIT provides automatically documents for presentation to supervisory authorities in form of Excel reports. Analysis results are automatically taken from analysis equipment or can be manually entered. Completeness and...

Open the catalog to page 9
Flyer HIGH-LEIT - 10

System Architecture HIGH-LEIT with its decentralized structure is an open system with scalable computing capacity. Control level, process connection, user level as well as additional dedicated computers for special tasks are linked together via a high speed network. Redundant configuration in “hot-standby mode” is possible for all system components. Additional functional servers are integrated for e.g. simulation or training tasks, for database applications or any other CPU-intensive computations (load flow calculations, dynamic gas network simulation). Control and user levels embody a...

Open the catalog to page 10
Flyer HIGH-LEIT - 11

Sample configuration IDS HIGH-LEIT Control room workstations Wall display Office workstations HMI HM I HMI HMI Router/ Firewall redundant control room LAN OPC Gatewa y FEC FEC Server 1 Server 2 Router ISDN telemetry/ automation technology HMI: FEC: WEB HMI Human-machine interface Front end computer home office/ remote diagnosis TerminalServer TerminalHMI Office LAN WebInterface data base

Open the catalog to page 11
Flyer HIGH-LEIT - 12

HIGH-LEIT is designed for applications of energy and water supply, for sewerage and environmental areas as well as for industrial requirements. The system offers – independently from the hardware platform and the operating system used – user friendly solutions for all tasks of process visualization, monitoring, control and automation. IDS GmbH Nobelstraße 18 Phone +49 72 43 218-0 Fax +49 72 43 218-1 00 E-Mail info@ids.de n HIGH-LEIT is a registered trademark of IDS Internet www.ids.de n Technical specifications subject to change GPM.10064.09096 D-76275 Ettlingen

Open the catalog to page 12

Archived catalogs

  1. ACOS X4

    4 Pages

  2. ACOS NMS

    8 Pages

  3. ACOS NMS

    8 Pages

  4. Flyer_ACOS_7

    8 Pages