Catalog excerpts
Multi-Functional Digital Integrated Power Meter CONTENTS Features······················································································ 7-02 C Exterior & Part Names····························································· 7-04 C Performance·············································································· 7-05 C Low Voltage Monitoring Function············································ 7-06 C Connecting Method····
Open the catalog to page 1Multi-Functional Digital Integrated Power Meter _ Feature VIDER-M5, an intelligent power meter, is designed applied with an up-to-date microprocessor and an advanced digital signal processing technology. A digital integrated power meter, it is equipped with various conventional incoming panel and intelligent panel board-based mechanical, analog meter functions. It displays THD as well as current and voltage harmonics up to the 32nd harmonic. In addition, it provides the maximum/minimum voltage/current parameters. It is mounted in front, receiving CT and PT of the distribution panel and the...
Open the catalog to page 2Main Features Measured parameters of the power line can be monitored by five 7-Segments Display Windows, and CT ratio and PT ratio can be set using the front panel. It is displayed with the phase voltage, average phase voltage, phase-phase voltage, average phase-phase voltage, active power, reactive power, apparent power, active electric energy, reactive electric energy, apparent electric energy, frequency, power factor, peak power and harmonics. Also, the load factor of the power line being used is numerically displayed to intuitively check the load status. VIDER-M5 Application Range...
Open the catalog to page 3Exterior / Performance Exterior & Part Names Voltage Hotline Lamp Up Button (Each Phase Selection Button) Each Phase Display Window Down Button (Each Phase Selection Button) Communication Lamp Average Value Selection Button Average Value Display Window Total Value Selection Button Max/Min Value Selection Button Total Value Display Window PF, Hz, W, Wh, Var, Varh, VA, Vah Display Lamp & Selection Setting Mode: It is used to increase the parameter input value and to move to the next menu. Setting Mode: It is used to decrease the parameter input value and to move the previous menu. Setting...
Open the catalog to page 4Standard Operating Environmnet • Temperature -Normal Operating Temperature : -10℃ ~ 55℃ -Storage Temperature : -25℃ ~ 70℃ Humidity • Humidity - Humidity of 85% or less (Without any dew formation) • Location Setting - Altitude : Altitude of 2,000m or under - Place without any abnormal vibration and impact - Place without severely contaminated air condition Connecting Method 3Phase-3Wire, 3Phase-4Wire, Single Phase 2Wire, Single Phase 3Wire Input Range Insulation Resistance Commercial Frequency Withstanding Voltage Transient Response(EFT Burst) Static Energy(ESD) Overload Capability Standard...
Open the catalog to page 5Performance / Low Voltage Monitoring Function / Connecting Method Measurement Display Range Parameter Display Range Phase Voltages Phase-Phase Voltages Phase Currents Total Currents Active Power Reactive Power Apparent Power Power Factor Export Active Energy Export Reactive Energy Average Phase Voltage Average Phase-Phase Voltage Total Active Power Total Reactive Power Total Apparent Power Voltage Harmonic Voltage Harmonics(option) Current Harmonic Current Harmonics(option) ※ Tolerance for ratings ※ Voltage harmonic, current harmonic options Low Voltage Monitoring Function Voltage Hotline...
Open the catalog to page 6Connecting Method
Open the catalog to page 7Connecting Method Connecting Method
Open the catalog to page 8Connecting Method
Open the catalog to page 9Connecting Method / Terminal Block & External Size Connecting Method
Open the catalog to page 10Terminal Block Communication Terminal Voltage Input Current Input Control Power Input CUTTING SIZE
Open the catalog to page 11All VitzroEM Co. catalogs and technical brochures
-
Vacuum Transfer Switch
11 Pages
-
ATS controller (VITAC200)
7 Pages
-
MCCB
24 Pages
-
Load Break Switch (LBS)
13 Pages
-
Comprehensive Low Voltage Equipment
336 Pages
-
Power Fuse
21 Pages
-
Vacuum Interrupter (VI)
10 Pages
-
ACB OCR User Manual
50 Pages
-
Air Circuit Breaker (ACB)
90 Pages
-
Automatic Transfer Switch
55 Pages
-
VIDER-M4
11 Pages
-
Surge Protective Device
48 Pages