VIDER-M4 - 1

Multi-Functional Digital Integrated Power Meter CONTENTS Features······················································································ 8-02 C Exterior & Part Names····························································· 8-04 C Performance·············································································· C8-05 Low Voltage Monitoring···························································· 8-06 C Connecting

Open the catalog to page 1
VIDER-M4 - 2

Multi-Functional Digital Integrated Power Meter _ Feature VIDER-M4 is a digital integrated power meter that is installed with various mechanical, analogue meter functions based on the existing distribution/receiving panel mode. The panel is mounted in front, receiving CT and PT inputs of distribution panel and rectifier panel so as to measure all the electrical elements of the power line and its case is inflammable with 110x110m in size. The device is designed with an up-to-date microprocessor and an advanced digital signal processing technology. All the electrical parameters are measured...

Open the catalog to page 2
VIDER-M4 - 3

Main Features Measured parameters of the power line can be monitored by three 7-Segments Display Windows, and CT ratio and PT ratio can be set using the front panel. It is displayed with the phase voltage, phase-phase voltage, phase current, active power, reactive power, apparent power, active electric energy, reactive electric energy, apparent electric energy, frequency, power factor and load factor. Also, the load factor of the power line being used is numerically displayed to intuitively check the load status. The voltage input value is set and if a value is input that is less than the...

Open the catalog to page 3
VIDER-M4 - 4

Exterior & Part Names / Performance Exterior & Part Names Voltage Display Window Voltage Phase Selection Key Voltage Fail Lamp(Open-Phase) Current Phase Display Lamp Current Display Window Current Phase Selection Key PF, Hz, W, Wh, Var, Varh, VA, Vah Display Window PF, Hz, W, Wh, Var, Varh, VA, Vah Display Window Communication Lamp Voltage Phase Display Lamp Average Load Factor Display Setting Mode: It is used to increase the parameter input value and to move to the next menu. Setting Mode: I t is used to decrease the parameter input value and to move the previous menu. Setting Mode: Press...

Open the catalog to page 4
VIDER-M4 - 5

Standard Operating Environment • Temperature -Normal Operating Temperature : -10℃ ~ 55℃ -Storage Temperature : -25℃ ~ 70℃ • Humidity : Humidity of 85% or less (Without any dew formation) • Location Setting - Altitude : Altitude of 2,000m or under - Place without any abnormal vibration and impact - Place without severely contaminated air condition Input Rating Item Connecting Method 3Phase-3Wire, 3Phase-4Wire, Single Phase 2Wire, Single Phase 3Wire Input Range Commercial Frequency Withstanding Voltage Transient Response(EFT Burst) Static Energy(ESD) Current Circuit Standard Operating...

Open the catalog to page 5
VIDER-M4 - 6

Performance / Low Voltage Monitoring Function / Connecting Method Measurement Display Range Parameter Display Range Phase Voltages Phase-Phase Voltages Phase Currents Active Power Reactive Power Apparent Power Power Factor Active Energy Reactive Energy Apparent Energy Average Load Factor Load Factor Low Voltage Monitoring Function Voltage Monitoring Lamp When a voltage lower than the set value is generated at 3phase-3wire and 3phase-4wire lines, Va, Vb and Vc lamps are turned on to intuitively check the PT fuse status or the under voltage status of the line.

Open the catalog to page 6
VIDER-M4 - 7

Connecting Method

Open the catalog to page 7
VIDER-M4 - 8

Connecting Method Connecting Method

Open the catalog to page 8
VIDER-M4 - 9

Connecting Method

Open the catalog to page 9
VIDER-M4 - 10

Connecting Method / Terminal Block / External Size Connecting Method

Open the catalog to page 10
VIDER-M4 - 11

Terminal Block Control Power Terminal Voltage Terminal Communication Terminal Current Terminal External Size

Open the catalog to page 11

All VitzroEM Co. catalogs and technical brochures

  1. MCCB

    24 Pages

  2. Power Fuse

    21 Pages

  3. VIDER-M5

    11 Pages