B6 Current Limiting Power Fuses CONTENTS Features····················································································· B6-02 Configuration············································································· B6-04 Application ················································································ B6-06 Ratings······················································································· B6-08 Fuse Selecting Conditions & Cri
Open the catalog to page 1Current Limiting Power Fuses VITZRO EM Current Limiting Power Fuse passed the development test carried out by an official authentication organization and it is recognized for its superior quality and short circuit capability. It is an advanced product designed by applying the accumulated technology and experiences in the field It ensured the maximum breaking capacity within the same rating It is possible to provide various fuse ratings due to the development of 7.2kV 50kA and 10A~200A, 24/25.8kV 40kA and 1A 160A With to the development of 25.8kV Class current limiting, it can be used at...
Open the catalog to page 3Configuration Fuse Link Fuse Holder Diameter : Rated Current : Vacuum Contactor Switch VCS • 3.6/7.2kV • 50kA • Indoor Type Load Break Switch LBS • 24kV 40kA 630A • Electric Type
Open the catalog to page 4Current Limiting Power Fuses Fuse Link Fuse Holder Current Limiting Power Fuses Diameter : Rated Current : VITZRO EM Current Limiting Power Fuse interrupts the short circuit current within the shortest time through the current limitation that prevents the short circuit current generated by the resistance within the fuse from reaching the crest value when much short circuit current flows. It is a protection device to minimize the mechanical and thermal damages that are generated in the switch and control system circuits.
Open the catalog to page 5Application Accessories • For the transformer circuit - To interrupt the fault current of transformer secondary short circuit & transformer circuit • For the Capacitor circuit - To interrupt the fault current of Capacitor circuit • For the back-up protection of circuit breakers & switches - For the back-up protection if the breaking capacity of CB and Switches is not enough • For the cable circuit - To protect the cable by interrupting the fault current of circuit • or the motor circuit - To interrupt the fault current of circuit where much over-current F flows when the motor starts and to...
Open the catalog to page 6Current Limiting Power Fuses Table on Main Characteristics About 4 ~ 5 times the rated current, fuse has expanded the protection area Rated Current Development tests on all ratings ranging from minimum 1A up to 200A completed Current Limiting Characteristic Sharp decrease in the crest value of fault current in case of a fuse short circuit fault due to the excellent current-limiting characteristic Time-Current Characteristics External Dimensions Easy to select within the maximum error range of ±10% Fuse Link Length Fuse Link Diameter Energy Delivery Delivers the maximum operating energy...
Open the catalog to page 7Ratings Striker 3.6/7.2kV Fuse Link Ratings Rated Max. Breaking Current [kA] Rated Min. Breaking Current [A] Rated Voltage Rated Max. Breaking Current ※For both indoors and outdoors ※For indoors ※How to order : Refer to the following product type and order type Order Information Rated Current : Refer to the table of rating specification Fuse Link Fuse Link * Striker (Fuse Checker) is optional. Diameter of Removable Hook 5 6
Open the catalog to page 8Current Limiting Power Fuses 24/25.8kV Fuse Link Ratings Rated Max. Breaking Current [kA] Rated Min. Breaking Current [A] External Dimensions Rated Voltage Rated Max. Breaking Current ※When applying VTHF24200, please contact our company. Current Limiting Power Fuses
Open the catalog to page 9All VitzroEM Co. catalogs and technical brochures
-
Vacuum Transfer Switch
11 Pages
-
ATS controller (VITAC200)
7 Pages
-
MCCB
24 Pages
-
Load Break Switch (LBS)
13 Pages
-
Comprehensive Low Voltage Equipment
336 Pages
-
Vacuum Interrupter (VI)
10 Pages
-
ACB OCR User Manual
50 Pages
-
Air Circuit Breaker (ACB)
90 Pages
-
Automatic Transfer Switch
55 Pages
-
VIDER-M5
11 Pages
-
VIDER-M4
11 Pages
-
Surge Protective Device
48 Pages