Catalog excerpts
Multi-Functional Digital Meter CONTENTS Features······················································································ 6-02 C Exterior & Part Names····························································· 6-04 C Performance·············································································· 6-05 C Operating Characteristics···················
Open the catalog to page 1Multi-Functional Digital Meter _ Feature Unlike the other devices that require peripheral analogue or digital meters to configure a system, VIDER-M20 is equipped with all the digital measurement factors in the body to minimize any timely and spatial loss, ensuring the reliability and precision of all measured parameters based on the digitization. VIDER-M20 uses DSP to perform a highly reliable, precise measurement, and the measurement factors are repeatedly calculated to enable a precise and high-speed measurement.
Open the catalog to page 2VDIER-M20 is a multi-functional digital integrated meter designed to suit the power quality, measurement and control specifications required on-site using the most advanced measurement technologies. It is capable of monitoring different measurement factors as a way to handle power systems that are becoming ever more complex. I nstalled with various measurement factors of the power system and controls CB D isplays the phase data of voltage/current and monitors the error correction, load status and so forth with the naked eyes U ses Digital Filter to remove various noise waveform on the...
Open the catalog to page 3Exterior & Part Names / Performance Exterior & Part Names POWER, RUN, ALARM, SYS FAIL LED Local/Remote LED(Key) Up/Down, Left/Right, Enter Key
Open the catalog to page 4Standard Operating Environmnet • Temperature -Normal Operating Temperature : -10℃ ~ 55℃ -Storage Temperature : -25℃ ~ 70℃ • Humidity - Humidity of 80% or less (Without any dew formation) • Location Setting - Altitude : Altitude of 2,000m or under - Place without any abnormal vibration and impact - Place without severely contaminated air condition Input Rating Item Connecting Method Control Power Zero Phase Voltage Zero Phase Current Measurement Range Digital Input Power Digital Input Counts Digital Output Counts Input Load
Open the catalog to page 5Performance / Operating Characteristics Measurement Display Range Item Display Range Phase Voltage Phase-Phase Voltage Zero Phase Voltage Zero Phase Current Active Power Reverse Active Power Reactive Power Apparent Power Active Electric Energy Reactive Electric Energy Apparent Electric Energy Reverse Active Power Power Factor Voltage Harmonics Current Harmonics Analog Input MAX Zero Phase Voltage MAX Zero Phase Current Demand Current Demand Power Voltage Phase Angle ※ Precision on Full Rang
Open the catalog to page 6Contact input/output Type Rating Signal source input voltage and current AC/DC110, 125V, 5mA (R/Y Auxiliary contact capacity) Resistive Load : C 250V, 10A A DC 30V 10A COSØ=1.0 Resistive Load : C 250V, 5A A DC 30V 5A COSØ=1.0 CB Status & Run Display LED LAMP Name Turned on when CB status is ON Turned on when CB status is OFF Turned on when the power is input Turned on when the system is under operation System Fail Turned on when the system fails Turned on when the alarm operates Turned on when TX communication is used Turned on when RX communication is used Turned on when CB control...
Open the catalog to page 7Connecting Method Connecting Method Communication Terminal
Open the catalog to page 8Connecting Method
Open the catalog to page 9Connecting Method / External Size Connecting Method Terminal Block
Open the catalog to page 10External Size CUTTING SIZE
Open the catalog to page 11All VitzroEM Co. catalogs and technical brochures
-
Vacuum Transfer Switch
11 Pages
-
ATS controller (VITAC200)
7 Pages
-
MCCB
24 Pages
-
Load Break Switch (LBS)
13 Pages
-
Comprehensive Low Voltage Equipment
336 Pages
-
Power Fuse
21 Pages
-
Vacuum Interrupter (VI)
10 Pages
-
ACB OCR User Manual
50 Pages
-
Air Circuit Breaker (ACB)
90 Pages
-
Automatic Transfer Switch
55 Pages
-
VIDER-M5
11 Pages
-
VIDER-M4
11 Pages
-
Surge Protective Device
48 Pages