Vitrek - Ground Integrity Analyzer
2Pages

{{requestButtons}}

Catalog excerpts

Vitrek - Ground Integrity Analyzer - 1

Ω .Performance that the other units cannot begin to match. > 3 to 30 amp test current - meets a wide variety of regulatory test specificationsՕPassword protected test routine storage Frequency synthesis 50-400Hz Օ10 բĦ resolution - more measurement confidence and repeatability4-wire Kelvin sensing - eliminates leadresistance errorsՕFully programmable via front panel, hipot or computer controlHipot and ground test from one set-up ՕHigh speed test throughout with actual measurement valuesDisplay prompted setup - easy to use, fully adjustableՕCEmark certified to EN 61010Made in the U.S.A. Օ5 Year extended warranty At Vitrek, we believe that your investmentin safety compliance equipment is an important one. The 930i Ground Integrity Analyzer is a case in point. The output current is fully user selectable from 3 to 30 amperes. So whether youre testing to a UL spec at 25 amps today or an IEC spec at 30 amps tomorrow, you can be sure that your Vitrek will stand up to the test for years to come.In fact, all test parameters of the 930i arefully programmable-output current, frequency, resistance limits and test duration. And whether youҒre running the 930i from its password protected test database or via computer control, ground bond testing has never been simpler or faster. > The 930i works hand-in-hand with Vitrek hipot testers so that dielectric testing and ground bond testing can be accomplished from a single set up. The results are automatically integrated into a unified test report with overall pass/fail status as well as step-by-step results with final values.Providing confidence in every test youmake is our job. Isnt it time to put the unrivaled performance of the 930i to work for your team? > To provide unparalleled accuracy, the Vitrek 930i employs a state of the art high speed, 4-channel, 16 bit analog to digital converter. The 930i simultaneously tracksand controls the output current, while measuring voltage drop across the load, and monitoring the status of both power supply and output amplifier.The four-wire Kelvin configuration elimi-nateslead resistance errors to provide measurement repeatability down to 10ҵ >

Open the catalog to page 1
Vitrek - Ground Integrity Analyzer - 2

Range: 3 to 30 amperes RMS, programmable Remote Interface: VICL and serialcom standard. PLCoptional Vitrek 930i Automatic GroundIntegrity Analyzer. . . . . . . . . . . . . . . . . . . Resolution: 1 amp Output Frequency: Compliance Voltage: Sinewave synthesis,50Hz to 400Hz 3 volts RMS Display: 40 character dot matrix illuminatedliquid crystal display TL115HC Outlet Test Adapter. . . . . . . . . . Regulation: 0.25% no load to full load K-4 4-wire 4-clip 30A lead set. . . . . . . . . . Indicators: L.E.D. status indicators Alarm: Audible and visual alarms providepass/fail indication K-2 4-wire...

Open the catalog to page 2

All Vitrek catalogs and technical brochures

  1. Vitrek Catalog

    48 Pages

  2. V7X SERIES

    4 Pages

  3. 4700

    4 Pages

Archived catalogs