Catalog excerpts
Solenoid Valves SVG0.S08 Valve Series SAE Cartridge - 350 bar Technical Data Maximum operating pressure Maximum flow Maximum internal leakage NC Single Lock Pilot Operated External component treatment Poppet Type 350 bar 40 l/min 0,25 cm3 / min @350 bar Zn/Fe - standard (96h) Zn/Ni (720h) O-ring Temperature Range Cross Section Oil Temperature Range Fluids Viscosities Minimum pull-in voltage Filtration Orientation Installation torque -30° C to 110° C (standard sealing NBR - BUNA-N) -30° C to 110° C Mineral - based or synthetics with lubricating properties 7,4 to 420 cSt 85% of nominal 20/18/15 ISO 4406 (maximum filtration admitted) No restrictions 40 - 45 Nm (Hex. 24) Solenoid operated, 2-way 2-positions, normally closed, Technical Specifications for characterization piloted poppet type, screw-in cartridge valve. Typically used as a blocking or load holding device for high pres- sure circuits. When the coil is de-energized, the SVG0. Coil Weight S08 acts as check valve allowing free flow from 2 to 1, SK.030 and SK.027 (coil) 18W (for more detalis see page 410-425) 0,110 kg the poppet lifts and opens the 1 to 2 flow path. In this Note: The performance chart illustrates flow handling capacity in both directions 1 to 2 (energized). p/Q curve is recorded at TOil = 40°C and 46 cSt. operation mode, flow from 2 to 1 is severely restricted. The rigid design using a 1-piece body contributes to minimize the effect of eccentricities in cavity and provides Performance Details while blocking from 1 to 2. When the coil is energized great reliability. Low pressure drop thanks to optimized flow path. Technical Features Cavity Details Ordering Code Flow (l/min) All external surfaces are zinc plated and corrosion-proof. All valve parts are made of high strength steel. Poppet is hardened and ground to ensure minimal wear and extended service life. Coil seals protect the solenoid system. Manual override options. Industry SAE common cavity. Note: All Solenoid cartridge valves listed in the present catalogue are designed to work with D.C. power supply. To work with A.C. power supply, a RAC coil and connector with rectifier must be used. For any additional information, please contact your Sales contact representative. Specifications may change without notice. NOTE: for more details see page 426-427.
Open the catalog to page 1All VIS HYDRAULICS SRL catalogs and technical brochures
-
ICV0.M18
1 Pages
-
ICV0.M16
1 Pages
-
CVH0.S10
1 Pages
-
CVH0.S09
1 Pages
-
CVH0.S08
1 Pages
-
CVHG.S08
1 Pages
-
CVZ0.S10
1 Pages
-
CVZ0.S09
1 Pages
-
CVZ0.S08
1 Pages
-
CVC0.M22
1 Pages
-
CVC0.M18
1 Pages
-
CVC0.S20
1 Pages
-
CVC0.S16
1 Pages
-
CVC0.S12
1 Pages
-
CVC0.S10
1 Pages
-
CVC0.S09
1 Pages
-
CVC0.S08
1 Pages
-
CVS4.S10
1 Pages
-
CPR
1 Pages
-
SAE08-3
1 Pages
-
CCS0
1 Pages
-
RVA0.M18
2 Pages
-
PCV0.S10
1 Pages
-
DVC0.S08
1 Pages
-
CVC5.S08
1 Pages