Filetfix III
2Pages

{{requestButtons}}

Catalog excerpts

Filetfix III - 1

Technical Data sheet Filetfix® III (anaerobic adhesive) for Only nals ssio profe Pipe-sealant for threaded joints in contact with Liquid Petroleum Gas, cold and hot water, air and petroleum products. • • • • Conforms to the Gaz de France specification WRAS drinking water approval DGVW(NG-5146BN0170) listed product for contact with potable water {except those to the TRGI 86/96 standard} Conforms to the European standard EN 751-1 Class H Virax Filetfix® III is an anaerobic adhesive which polymerises rapidly. It was developed to seal pipes carrying liquids or gases. It conforms to Gaz de France’s CERUG –MC2AL/Nº5758 specification for threads which conform to the ISO 7-1 standard (taper/parallel and taper/taper). Its open time allows the components to be adjusted after assembly but gives an instant pressure seal which makes it an advantageous replacement for traditional sealing methods. The components can easily be disassembled with standard tools. The product should be used before the use-by-date printed on the bottle. The life expectancy is dependent on the product being stored between 5ºC and 25ºC in its original packaging; if the storage conditions are not met the life expectancy of the product will be reduced. CAUTION DO NOT ADJUST JOINTS AFTER ADHESIVE IS CURED. DO NOT USE ANAEROBIC ADHESIVES IN APPLICATIONS WHERE THEY WILL COME INTO CONTACT WITH PURE OXYGEN OR STEAM. FILETFIX® CANNOT BE USED TO RECTIFY FAULTS IN DAMAGED THREADED JOINTS. When using with brass joints in hot-water installations, carry out test beforehand. NB Copper and its alloys give a very rapid polymerisation. Oxidised or passivated surfaces, as well as zinc, give a slower polymerisation. Before using the product for the first time we recommend that you read the Materials Safety Data Sheet on www. virax.fr. Filetfix® III should be used on clean, dry and degreased surfaces. We recommend the use of a solvent such as acetone. The product can be applied directly from the bottle onto the threads to be sealed. If large volumes or precise application are required, then we recommend that an automated system be employed. The components to be assembled should be tightened using standard tools and the normal torque. Caution: do not re-tighten joints that have already cured.

Open the catalog to page 1
Filetfix III - 2

Technical Data sheet Maximum service temperature (after polymerisation) Data valid for standard usage Maximum gap 0.3 mm At an average temperature of 20ºC Pressure < 7 bar Water Joint type Male/Female Copper alloys/ Copper alloys Copper alloys/ Steel or assembles of different metals Stainless steel/ Stainless steel Steel / Copper T = open time (during which the assembly can be adjusted) NB In the case of coated metal the open time is 5 minutes. The minimum service temperature after polymerisation is -55ºC If used in non-standard conditions the polymerisation time will vary. Contact us....

Open the catalog to page 2

All VIRAX catalogs and technical brochures

  1. VIRAX CATALOGUE

    204 Pages

  2. Catalogue

    184 Pages

Archived catalogs