9900P

9900P

9900P

Product catalog summary
Overview: The document provides technical specifications and guidelines for the DZR brass automatic balancing valve with threaded union F/F ends (ISO 7/1 Rp). It highlights the valve's compatibility, working conditions, material norms, and installation instructions.
Specifications:
  • The valve is TR CU 010 compliant and operates under a maximum pressure of 25 bar up to 110°C, and 20 bar above 110°C.
  • It is suitable for water temperatures ranging from -10°C to +130°C, with specific conditions for antifreeze and anti-boiling fluids.
  • Flow ranges vary by valve size: DN15 and L-DN20 (0.02l/s to 0.20l/s), H-DN15, DN20, and DN25 (0.13l/s to 0.95l/s), DN32, DN40, and DN50 (0.31l/s to 2.60l/s).
Material Norms:
  • Components are made from materials such as Brass EN12165 CW617N, DZR Brass EN12165 CW602N, EPDM Perox, and Stainless Steel EN10270-3 1.4310HS.
Cartridge Information:
  • Cartridges are available in various flow ranges and differential pressures, identified by a unique numeric code.
  • Flow regulation accuracy is within +/-5% of the nominal flow.
Installation Guidelines:
  • Ensure the flow direction matches the arrow on the valve body.
  • Flush the system before installing the cartridge and use pipes of the same nominal size for optimal flow regulation.
  • Water quality should comply with VDI 2035, and at least one strainer should be used per installation.
Contact Information: For further details, contact the manufacturer at Via Circonvallazione, 10, 13018 Valduggia (VC), Italy, Tel: +39 0163 47891, Fax: +39 0163 47895, or visit www.vironline.com.
See more

Catalog excerpts

9900P-1

Via Circonvallazione, 10 13018 Valduggia (VC), Italy Tel: +39 0163 47891 Fax: +39 0163 47895 www.vironline.com DZR brass automatic balancing valve With threaded union F/F ends (ISO 7/1 Rp) Wide range of flows available (see cartridges section) Valve bodies interchangeable with 9900V series bodies (please refer to specific technical sheet) TR CU 010 compliant PN25 (Max 25bar up to 110°C, max 20bar above) Free of CE marking (cat. according to Art. 4.3 Dir. 2014/68/EU) Working conditions Suitable for: water, -10°C to +130°C below 0°C only for water with added antifreeze fluids over 100°C only for water with added anti-boiling fluids (Glycolic-Ethylene and glycolic-propylene mixtures up to 50% may be used) Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/UE) Flow range from 0,02l/s to 0,20l/s for DN15 and L-DN20 valves Flow range from 0,13l/s to 0,95l/s for H-DN15, DN20 and DN25 valves Flow range from 0,31l/s to 2,60l/s for DN32, DN40 and DN50 valves N. Part 1 Union nut 2 Union1 3 Union O-ring 4 Spring 5 Body 6 Cartridge OR 7 Shaped opening 8 Cartridge body 9 Cartridge spring Brass DZR Brass EPDM Perox Stainless steel DZR Brass EPDM Perox Stainless steel DZR Brass Stainless steel For valve body without cartridge 160401 Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them withou

 Open the catalog to page 1
9900P-2

Cartridges are available in different ranges of working differential pressure, the minimum and maximum working therefore depend on the specific cartridge model. A numeric code is marked on the cartridge body univocally identifying it (example for KRR992215.1880). Flow Nominal cartridge flow Flow regulation accuracy +/-5% of nominal flow Via Circonvallazione, 10 13018 Valduggia (VC), Italy Tel: +39 0163 47891 Fax: +39 0163 47895 www.vironline.com Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.

 Open the catalog to page 2
9900P-3

Standard range SMALL: for H-DN15, DN20 and DN25 valves HP range VIR Code Flow Flow RangeAP [l/s] [l/h] [kPa] Standard range MEDIUM: for DN32, DN40 and DN50 valves HP range Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.

 Open the catalog to page 3
9900P-4

Install the valve so that the flow direction matches the direction of the arrow indicated on the body of the valve. Perform correct flushing of the plant before installing the cartridge. In order to obtain the best correct flowrate regulation the valves should be installed using pipes of its same nominal size. Water quality should be according VDI 2035. Use at least one strainer for each installation. Via Circonvallazione, 10 13018 Valduggia (VC), Italy Tel: +39 0163 47891 Fax: +39 0163 47895 www.vironline.com Drawings, photos and data contained in this card are provided for information only....

 Open the catalog to page 4