Viking Master Catalog Combined
560Pages

{{requestButtons}}

Catalog excerpts

Viking Master Catalog Combined - 1

MASTER CATALOG UPDATED 4/1/16 SCAN FOR UP-TO-DATE CATALOG SECTIONS VP.SALESMRC.COM

Open the catalog to page 1
Viking Master Catalog Combined - 2

THIS PAGE INTENTIONALLY LEFT BLANK

Open the catalog to page 2
Viking Master Catalog Combined - 4

THIS PAGE INTENTIONALLY LEFT BLANK

Open the catalog to page 4
Viking Master Catalog Combined - 5

Sections Grouped by Pumping Principle Some sections group models by the design or pumping principle rather than the external material of construction. To assist identification in those sections, the models which correspond to the listed external material have been highlighted. INTERNAL GEAR PUMPS Heavy Duty General Purpose Heavy Duty CAST IRON, DUCTILE IRON 630 — HEAVY DUTY UNIVERSAL SEAL PUMPS (Jacketed and Non-Jacketed - Cast Iron, Ductile Iron, Steel, Stainless Steel) 144 — SERIES 495 AND 4195 (High Speed, Cast Iron) 710 — SERIES 4076 AND 4176 (Motor Speed, Ductile Iron) 430 — HEAVY DUTY...

Open the catalog to page 5
Viking Master Catalog Combined - 6

SECTION PAGE TABLE OF CONTENTS Sections Listed in Numerical Order 010 — HOW TO USE THIS CATALOG, 030 — SALES POLICY AND WARRANTY, U.S. DISTRIBUTOR RETURN POLICY, 040 — MODEL NUMBER SYSTEM & INDEX, 060 — DISPLACEMENT - INTERNAL GEAR PUMPS 144 — SERIES 495 AND 4195 Internal Gear Pumps (High Speed, Cast Iron) 154 — SERIES 493 AND 4193 Internal Gear Pumps (High Speed, Steel Externals) 164 — SERIES 4197 Internal Gear Pumps (High Speed, Stainless Steel) 210 — SERIES 724 AND 4724 Internal Gear Pumps (Heavy-Duty, Stainless Steel) 230 — HYGIENIC SERIES 157B, 4157B, 257B, 4257B Internal Gear Pumps...

Open the catalog to page 6
Viking Master Catalog Combined - 7

This Viking indexed catalog is organized in a convenient manner for quick referral. The table of contents on the first tab divider (Section 000) lists the organization of the catalog by section number and pump series. In this section is: • • • • • • The Viking Sales Policy with warranty Viking U.S. Distributor Return Policies An explanation of the model numbering system An index of model numbers to indicate the catalog section in which they are found An Internal Gear Pump Displacement and Element Size Chart An External Gear Pump Displacement and Element Size Chart Each section includes...

Open the catalog to page 7
Viking Master Catalog Combined - 8

THIS PAGE INTENTIONALLY LEFT BLANK

Open the catalog to page 8
Viking Master Catalog Combined - 9

SECTION PAGE VIKING SALES POLICY VIKING SALES POLICY Cancellation Charges WARRANTY Viking warrants all products manufactured by it to be free from defects in workmanship or material for a period of one (1) year from date of startup, provided that in no event shall this warranty extend more than eighteen (18) months from the date of shipment from Viking. The warranty period for Universal Seal series pumps ONLY is three (3) years from date of startup, provided that in no event shall this warranty extend more than forty-two (42) months from the date of shipment from Viking. The warranty period...

Open the catalog to page 9
Viking Master Catalog Combined - 10

THIS PAGE INTENTIONALLY LEFT BLANK

Open the catalog to page 10
Viking Master Catalog Combined - 11

Section Page VIKING U.S. DISTRIBUTOR RETURN POLICIES All Returns must be submitted using the electronic RGA module available in IDEXconnect. If you are not familiar with the use of this electronic return form you can locate it on IDEXconnect by clicking on Service, then Return Authorization Request, select Viking Pump, then simply fill out the request form provided and submit for approval. Once you receive approval for the return you can print shipping labels and a packing slip using this system. Only the approved items will print on the packing slip. Once a return is received at Viking you...

Open the catalog to page 11
Viking Master Catalog Combined - 12

VIKING U.S. DISTRIBUTOR RETURN POLICIES • Parts or pumps received at Viking Pump damaged, corroded, or in otherwise un-saleable condition will be returned at the Distributor’s expense, or disposed of at Viking Pump if so instructed by the Distributor. • Each Distributor will be assigned two quarters per year to execute the stock exchange. The exchange must occur in the first month of the assigned quarter. If a Distributor misses it’s assigned time period, it will be required to wait for it’s next authorized time period. If the Distributor returns inventory only once per year the dollar...

Open the catalog to page 12
Viking Master Catalog Combined - 13

SECTION PAGE VIKING MODEL NUMBER SYSTEMS The model numbering systems for different pumping principles are explained below. Series Number (2 to 6 characters long) SERIES NUMBER BY MATERIAL OF CONSTRUCTION PUMP SERIES CATALOG SECTION Heavy Duty Heavy Duty Heavy Duty Heavy Duty General Purpose General Purpose Jacketed Asphalt Electrically Heated Asphalt Universal Seal CAST IRON DUCTILE IRON STAINLESS STEEL Pump Size (Capacity) The first one or two alpha characters in the model number indicate the pump size (capacity). Note that the nominal capacities and maximum speed (RPM) are different for...

Open the catalog to page 13
Viking Master Catalog Combined - 14

INTERNAL GEAR PUMPS (CONTD.) Drive The drive letter indicates the drive configuration used to operate the pump, as follows: DRIVE LETTER DRIVE TYPE V-Belt Unit Viking Reducer Unit Direct Drive Unit Purchased Reducer Unit Bracket Mounted Unit Motor Mounted Unit Engine Drive Unit Direct Drive (Sanitary Base) UL Listing Certain series may be UL Listed for specific fluids, with a letter designation, as follows: UL LETTER EXTERNAL (SPUR) GEAR PUMPS PUMP SERIES CATALOG SECTION SG Series External Gear Single & Double Pumps, Mag Drive Pumps; GP Fluid Power Pumps; GM Hydraulic Motors; SG Power...

Open the catalog to page 14
Viking Master Catalog Combined - 15

SECTION PAGE VIKING INTERNAL GEAR PUMP DISPLACEMENT AND ELEMENT SIZE TABLE For metering applications, it can be useful to know the displacement per revolution to calculate capacity at different operating speeds. That information is provided in the table below. For critical metering, actual displacement should be determined through calibration under normal operating conditions. To aid in determining the pump size for unlabeled spare rotors or idlers, or to determine the size of a pump whose nameplate is missing, the approximate dimensions of the rotor and idler are also provided in the table...

Open the catalog to page 15
Viking Master Catalog Combined - 16

SECTION PAGE VIKING EXTERNAL GEAR PUMP DISPLACEMENT AND ELEMENT SIZE TABLE For metering applications, it can be useful to know the displacement per revolution to calculate capacity at different operating speeds. That information is provided in the table below. For critical metering, actual displacement should be determined through calibration under normal operating conditions. To aid in determining the pump size for unlabeled spares, or to determine the size of a pump whose nameplate is missing, the approximate dimensions of the gears are also provided in the table below. Pump Size...

Open the catalog to page 16

All Viking Pump catalogs and technical brochures

  1. XPD Brochure

    7 Pages

  2. 4076, 4176

    8 Pages

Archived catalogs