Catalog excerpts
VIKING HEAVY DUTY MOTOR SPEED PUMP Section Page Viking 4076/4176 (standard pump) GPM Major Design Features Designed to run with 50Hz synchronous motor speeds while providing high capacity. Enlarged porting and loading groove provides improved suction performance and reduced NPSHr. Optimized gear geometry delivers high-speed performance with improved noise levels. Metric design includes DIN flanges, DIN seal chamber, IEC motor mount, metric fasteners and shaft extension. DIN seal chamber accepts a wide range of seal options. Rotor shaft is designed to resist deflection and wear seen at higher speeds. Circulation line from the port to the mechanical seal provides liquid to the seal faces to extend seal life. Bearing housing assembly allows for adjustment of running clearances to compensate for slip and wear, extending the service life of the pump. Also provides additional shaft support in high pressure applications, and provides a method of shaft support other than the motor bearing. Pressure Range Six sizes available each with three mounting options; flange mount, motor bracket mount or with a bolt on foot for a base mount. Flow Range Ductile iron externals for thermal shock applications is an affordable alternative to steel. LQE4176 WITH BOLT ON FOOT ①Values shown represent minimums or maximums. Some special LQE4076 WITH FOOT BRACKET AND IEC MOTOR construction or consideration may be required before a cataloged pump can be applied to an application involving maximum pressure or minimum or maximum temperature and/or viscosity. ②Nominal capacities based on handling thin liquids at low pressures. VIKING PUMP • A Unit of IDEX C
Open the catalog to page 1Section Page VIKING HEAVY DUTY MOTOR SPEED PUMP CONSTRUCTION – SPECIFICATIONS Casing and Head Foot Plate Rotor Shaft and Idler Pin Ductile Iron Ductile Iron Ductile Iron Cast Iron Bushings Idler Carbon Graphite Carbon Graphite Relief Valve⑦ Ductile Iron Buna N / silicon carbide vs carbon Viton / silicon carbide vs carbon ⑤ Ductile iron jacketed head plate available as an option for all sizes. ⑥ Standard mechanical seal can be used for temperatures from -40° F to +400°F (- 40° to ① Clockwise (CW) rotation standard. Counterclockwise (CCW) rotation must be specified. ② Used on 4176 models...
Open the catalog to page 2VIKING HEAVY DUTY MOTOR SPEED PUMP Section Page PARTS IDENTIFICATION Mechanical Seal Bearing Housing Assembly Pressure Relief Valve (Coverplate shown) Seal Holder Plate Idler Shaft Idler Pin Casing Casing Bushing VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 3VIKING HEAVY DUTY MOTOR SPEED PUMP Dimensions given are for guidance only and should not be used for installation purposes. Certified dimensions will be supplied on request. DIMENSIONS – HLE4076 - LQE4076 PUMP ONLY G T R P - HOLES (N) PLACES All dimensions are in millimeters. MODEL NUMBER VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 4VIKING HEAVY DUTY MOTOR SPEED PUMP Section Page Dimensions given are for guidance only and should not be used for installation purposes. Certified dimensions will be supplied on request. DIMENSIONS – HLE4176 - LQE4176 PUMP ONLY G MODEL NUMBER VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 5VIKING HEAVY DUTY MOTOR SPEED PUMP Dimensions given are for guidance only and should not be used for installation purposes. Certified dimensions will be supplied on request. DIMENSIONS- BRACKET MOUNT SIZES HLE, ATE, AND ALE A- PORTS (DIN) MODEL NUMBER. MOTOR FRAME . Metric shaft couplings and key required. VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 6VIKING HEAVY DUTY MOTOR SPEED PUMP Section Page Dimensions given are for guidance only and should not be used for installation purposes. Certified dimensions will be supplied on request. DIMENSIONS- BRACKET MOUNT SIZES KE,KKE, AND LQE A- PORTS (DIN) MODEL NUMBER MOTOR FRAME VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 7VIKING HEAVY DUTY MOTOR SPEED PUMP SERIES 4076, 4176, Sizes HLE, ATE, ALE, KE, KKE, LQE Performance Curve Notes Printed performance curves are not available. Performance curves can be electronically generated with the Viking Pump Selector Program. This program can be located on www.vikingpump.com for the general public. For authorized distributors, this program can be found listed under the “Products” tab at www.idexconnect.com. Security passwords are required to access IDEXconnect. VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
Open the catalog to page 8All Viking Pump catalogs and technical brochures
-
OEM Custom Solutions
6 Pages
-
LVP Vane Pumps
8 Pages
-
Viking-Built Double Pumps
8 Pages
-
Dual Containment
1 Pages
-
855 Mag Drive Pumps
8 Pages
-
XPD Brochure
7 Pages
-
Motorspeed 2016 Infographic
2 Pages
-
Hygienic Series Poster
1 Pages
-
Hygienic Series
5 Pages
-
Viking Master Catalog Combined
560 Pages
-
HEAVY DUTY PUMPS, SERIES 4195
11 Pages
-
Metric Motor Speed
6 Pages
-
Universal Mag Drive
10 Pages
-
Universal Seal Pumps
16 Pages
-
Electric Heat
4 Pages
-
Viking Product Catalog
56 Pages
Archived catalogs
-
Composite Mag Drive
8 Pages
-
Gear Reducers
8 Pages
-
Power Load Monitors
2 Pages
-
SG External Gear Pumps
16 Pages
-
Lid-Ease® Basket Strainers
2 Pages
-
Universal Seal Pumps
16 Pages
-
Viking pump - Product Flyers
20 Pages