32EM-5-01, 32EM-5-02 – ENGINEERING SAMPLES-1

SYSTEM 32EM-5 detection modules series 32EM-5 is a series of 32-channel detection modules. Thermoelectrically cooled MWIR 32-element HgCdTe photovoltaic detector is integrated with DC-coupled 32-channel transimpedance preamplifier. Spectral response (Ta = 20°C, Vb = 0 mV) Specification (Ta = 20°C, Vb = 0 mV) Features ■ High sensitivity ■ Compact small size ■ Convenient cryogenic-free operation ■ External heatsink is necessary (recommended thermal resistance: ~2 K/W) ■ External TEC controller is necessary Applications ■ Spectroscopy (gas detection, breath analysis) ■ Slow and fast contactless temperature measurement (railway transport, industrial and laboratory processes monitoring) ■ Optical sorting systems ■ Laser beam profiling and positioning ■ Flame and explosion detection ■ Combustion process control Engineering samples are manufactured for purposes of research and development. Values of parameters mentioned in the datasheet are for guidance only and may not be used as guaranteed values. VIGO System S.A. reserves the right to change these specifications at any time without notification.

 Open the catalog to page 1
32EM-5-01, 32EM-5-02 – ENGINEERING SAMPLES-2

32EM-5 detection modules series XJiGOSYSTEM Mechanical layout, mm Details of active elements area Assembly diagram TEC supply input (+) TEC+ 1 Power supply input (+) +Vsup 3 Power supply input (-) —Vsup 22 Thermoelectric cooler parameters Engineering samples are manufactured for purposes of research and development. Values of parameters mentioned in the datasheet are for guidance only and may not be used as guaranteed values. VIGO System S.A. reserves the right to change these specifications at any time without notification.

 Open the catalog to page 2
32EM-5-01, 32EM-5-02 – ENGINEERING SAMPLES-3

32EM-5 detection modules series 32EM-5 series modules are equipped with the built-in thermistor to provide precise control and measurements of detector active elements temperature. The maximal power dissipated by the thermistor should not exceed 0.2 mW, therefore its bias must be carefully chosen. To provide accurate temperature measurement, this power should not exceed 0.03 mW. Resistance vs. temperature of the thermistor T,~K I T,'°C Engineering samples are manufactured for purposes of research and development. Values of parameters mentioned in the datasheet are for guidance only and may not...

 Open the catalog to page 3

All Vigo Photonics catalogs and technical brochures

  1. 4EM-5

    2  Pages

  2. microM-10.6

    3  Pages

  3. LabM-I-4

    3  Pages

  4. AM03100-02

    6  Pages

  5. FIP series

    2  Pages

  6. PIP SERIES

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.