Catalog excerpts
KWT: Heat pumps, refrigeration technology and primary sources for efficient energy utilisation KWT has great potential for developing new heat pump technology as it has more than 30 years' experience in this sector and has recently joined the Viessmann Group. Since the company was established in 1979, the engineers at KWT AG have spearheaded development in the efficient utilisation of cooling and heating energy. Company founder, Kurt Trüssel, has made a particular study of the energy contained in the waste heat from refrigeration systems. KWT continues to work intensively on transforming...
Open the catalog to page 3Heating with renewable energy from the environment – even in higher output ranges Natural heat provides an advanced and cost effective alternative to fossil fuels. It is available free of charge and offers independence from oil and gas. Heat pumps should be your rst choice if your priorities are both to save on heating costs and to generate heat in an environmentally responsible way. After all, the energy a heat pump uses is free and available in unlimited supply from the environment. Only electrical power is required to drive the heat pumps. This makes you independent of fossil fuels, and...
Open the catalog to page 5Vitocal 300-G/-W Pro: Brine/water and water/water heat pumps Standardised control concept and optimised dimensions perfectly complement Viessmann system design. With the new Vitocal 300-G/-W Pro heat pumps, Viessmann extends the company's range of standard heat pumps up to 290 kW. The Pro series features all the characteristics of the highly efficient Vitocal 300-G series. The ve output sizes enable most requirements from residential and commercial buildings to be reliably met. Standardising these appliances enables quick and comprehensive engineering, as well as providing transparent...
Open the catalog to page 7Take advantage of these benets: Brine/water heat pump, single and two-stage Heating output: 93 to 240 kW; maximum 1200 kW (as cascade) Water/water heat pump, single and two-stage Heating output: 122 to 290 kW; maximum 1450 kW (as cascade) Low operating costs through high coefficients of performance: COP (COP = coefficient of performance) to EN 14511 up to 4.8 (brine 0 °C/water 35 °C) and up to 5.9 (water 10 °C/water 35 °C) Maximum ow temperature 60 °C (brine 5 °C) Low noise and vibration emissions through sound-optimised appliance design Low running costs with the highest level of...
Open the catalog to page 8Vitocal 300-G Pro brine/water heat pump Vitocal 300-G Pro Dimensions Length Width Height Output data (to EN 14511, B0/W35 °C, 5 K spread) Rated heating output Cooling capacity Power consumption COP in heating mode Vitocal 300-W Pro water/water heat pump Vitocal 300-W Pro Output data (to EN 14511, W10/W35 °C, 5 K spread) Rated heating output Cooling capacity Power consumption COP in heating mode Dimensions Length Width Height
Open the catalog to page 9Vitocal 350-G Pro: Brine/water heat pump The new Vitocal 350-G Pro extends heat pump output from 27 to 198 kW with ow temperatures up to 73 °C. Based on the compressors with piston technology available for these output ranges, this heat pump has all the hallmarks of a powerful and efficient unit. In addition, the newly developed frame casing is easy to install and transport. The anti-vibration cladding (supplied separately) ts exactly and reduces the weight needed to be transported by around 200 kg. Equipment to meet customer needs The electrical equipment is fully integrated inside the...
Open the catalog to page 11Take advantage of these benets: Vitocal 350-G Pro Type BW 352 A156, internal view showing additional options Brine/water heat pump, two-stage Heating output: 27 to 198 kW High ow temperatures up to 73 °C Low operating costs through high coefficients of performance: COP value to EN 14511 up to 4.4 (brine 0 °C/water 35 °C) Viable under partial load conditions due to the use of two or three compressors with an equal output Low noise and vibration emissions through sound-optimised appliance design Intuitive use of the control unit via touchscreen with schematics Possibility of factory...
Open the catalog to page 12Vitocal 350-G Pro brine/water heat pump Vitocal 350-G Pro Dimensions Length Width (values in brackets excl. anti-vibration casing) Height Dimensions Length Width (values in brackets excl. anti-vibration casing) Height Output data (to EN 14511, B0/W35 °C, 5 K spread) Rated heating output Cooling capacity Power consumption COP in heating mode Output data (to EN 14511, W10/W35 °C, 5 K spread) Rated heating output Cooling capacity Power consumption COP in heating mode Output data (to EN 14511, B0/W35 °C, 5 K spread) Rated heating output Cooling capacity Power consumption COP in heating mode...
Open the catalog to page 13System solutions Investment and energy costs 10-family house, well insulated
Open the catalog to page 14Heat pumps for every application with any type of heat source With technical expertise, outstanding manufacturing ability and many years of experience, KWT is the heat pump manufacturer of choice for every special application. KWT works together with its clients to develop solutions that are based on more than 30 years' experience, that will meet practical, everyday needs, and that will overcome any and every challenge. All deadlines and costs arranged can be relied upon, with no unpleasant surprises. All systems are designed and built based on our customers' performance denitions. All heat...
Open the catalog to page 15Brine/water heat pumps KWT brine/water heat pump with a heating output of 290 kW
Open the catalog to page 16Using heat from the ground with geothermal probes A stable and highly durable heat source KWT brine/water heat pumps are built around expertise and quality. Geothermal probes are durable, maintenancefree heat sources. In conjunction with heat pumps, they provide energy for heating, but are also the ideal heat exchanger for natural cooling. In both cases, KWT brine/water heat pumps utilise the constant temperature in the ground. Optimum design KWT brine/water heat pumps are designed and manufactured in accordance with requirements. Economical and cost effective ow temperatures of 35 to 40 °C...
Open the catalog to page 17All Viessmann Werke GmbH & Co KG catalogs and technical brochures
-
Vitocal 150-A/151-A
20 Pages
-
Vitocal 200-A
4 Pages
-
Vitodens 200-W
4 Pages
-
Vitodens-222-F
4 Pages
-
Vitodens 050-W
4 Pages
-
Product Range Overview
20 Pages
-
Photovoltaic systems
20 Pages
-
Hybrid solutions
24 Pages
-
Gas condensing technology
40 Pages
-
Oil condensing technology
32 Pages
-
Etanomics
16 Pages
-
Wood boilers
42 Pages
-
Heat pumps
72 Pages
-
DHW cylinder Vitocell
36 Pages
-
Power to gas
4 Pages
-
Mechanical ventilation systems
36 Pages
-
Thermal solar systems
34 Pages
-
Gas processing plants
16 Pages
-
Power-generating heating systems
24 Pages
-
Wood boilers from 8 to 170 kW
42 Pages
-
Gas condensing technology
48 Pages
-
Fuel cell boiler
16 Pages
-
Solutions generating energy
24 Pages
-
CHP units for heat and power
20 Pages
-
Biogas upgrading plants
20 Pages
-
Energy from the sun
46 Pages
-
VITOTWIN 300-W
4 Pages
-
DHW cylinders Vitocell
32 Pages
-
Micro CHP boiler
12 Pages
-
A perfect climate for your home
20 Pages
-
Heating with wood
56 Pages
-
Power from the sun
20 Pages
-
Heating with gas
74 Pages
-
Heating with oil
72 Pages