The load capacity ranges from 15 daN to 230 daN depending on the model type.
Deflection values vary between 3.5 mm and 10 mm, indicating the displacement under load.
Natural frequency ranges from 5 Hz to 9 Hz, showing the vibration characteristics of the components.
Static stiffness values range from 5.5 daN/mm to 11 daN/mm, representing resistance to deformation under static load.
Hardness is specified as 65±3 Shore A for some models, indicating material surface hardness.
Several model types are listed with corresponding load, deflection, frequency, stiffness, and hardness values. Dimensions are provided for each model, including parameters A, B, C, D, E, ØF, ØG, H, and I in millimeters.
The document references a static force-deflection curve, which illustrates the relationship between applied force and resulting deflection, critical for understanding component behavior under load.
Vibrostop MMC APPLICAZIONI Applications MATERIALI Materials CARATTERISTICHE Features TEST SUPERATI Tests passed • Supporto antivibrante ed antiurto specifico per impieghi navali: idoneo sia alia protezione degli apparati dagli shock sia all'isolamento di rumore strutturale e vibrazioni eventualmente generati dagli apparati stessi. VIBROSTOP SRL - Via Savona, 97 - 20144 Milano, Italy - Tel. +39-02-4895.0008 Fax +39-02-4895.3807 -
Open the catalog to page 1MODELLO Type MODELLO Type VIBROSTOP SRL - Via Savona, 97 20144 Milano, Italy - Tel. +39-02-4895.0008 Fax +39-02-4895.3807 - www.vibrostop.it
Open the catalog to page 2CONFIGURAZIONI TIPICHE Typical layout BASE VIBROSTOP SRL - Via Savona, 97 - 20144 Milano, Italy - Tel. +39-02-4895.0008 Fax +39-02-4895.3807 - www.vibrostop.it
Open the catalog to page 3Immagini delle prove svolte secondo MIL-S-901 D (S.T.I. MM-305) - a sinistra prima dell'urto, a destra nel momento del massimo allungamento dopo I'impatto Images of the tests carried out according to MIL-S-901 D (STI MM-305) - On the left before impact, on the right at the moment of the maximum elongation after impact Grafico della prova di resistenza alio shock secondo MIL-S-901 D (o STI MM-305) - INPUT Diagram of the shock resistance test according to MIL-S-901 D (or STI MM-305) - INPUT Grafico della prova di resistenza alio shock secondo MIL-S-901 D (o STI MM 305) - OUTPUT Diagram of the shock...
Open the catalog to page 4Misura dell'isolamento dal rumore strutturale Measuring isolation from structure-borne noise BASSE FREQUENZE Low frequency MEDIO-ALTE FREQUENZE Mid-high frequencies VIBROSTOP SRL - Via Savona, 97 , - 20144 Milano, Italy - Tel. +39-02-4895.0008 Fax +39-02-4895.3807 - www.vibrostop.it
Open the catalog to page 53 Pages
8 Pages
23 Pages
2 Pages
8 Pages
1 Page
3 Pages
1 Page
2 Pages
2 Pages
4 Pages
3 Pages
6 Pages
21 Pages
91 Pages
1 Page
3 Pages
5 Pages
2 Pages
6 Pages
2 Pages
14 Pages
2 Pages
3 Pages
1 Page
27 Pages
8 Pages
2 Pages
5 Pages
4 Pages
27 Pages
21 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
1 Page
8 Pages
2 Pages
3 Pages
3 Pages
7 Pages
170 Pages