UAT 978 MHz Option

UAT 978 MHz Option

UAT 978 MHz Option

Product catalog summary
Overview: The VIAVI UAT 978 MHz Option provides testing capabilities for UAT receivers, including compliance with DO-282 MOPS standards. It is accessible from the Scenario Screen and supports various test modes tailored for different MOPS tests.
UAT Setup Requirement: The UAT scenario requires a 1 PPS signal input in TX Mod #1 on the RGS2000NG to operate.
Common Capabilities: Each channel supports 32 dynamic and 1500 static targets, which can be airborne or ground link messages. Users can adjust the eye diagram's horizontal spacing and select filters to modify frequency transitions. Targets can be defined relative to an aircraft's position or as an offset from the Message Start Opportunity (MSO).
Test Applications: The RGS-2000NG NextGen TCAS Test Set is suitable for engineering development, certification, manufacturing, and service. It performs MOPS tests for various standards including DO-185A/B, DO-260/A/B, DO-181E, and DO-300, and is compatible with TCAS computers, ADS-B In Receivers, and more.
UAT Test Modes:
  • Normal Mode: Two transmitters are available, with UAT RX1 and RX2 connected to different antennas.
  • Overlapping Mode: Combines transmitters to test overlapping UAT message reception.
  • DME Fruit Modes: Supports 12 μS and 30 μS spacing for DME fruit tests, allowing user selection of power and frequency.
  • Retrigger Modes: Tests receiver retrigger capability with long ADS-B and ground link messages.
  • 1090 Pulse Interference Mode: Tests interference with user-defined power and frequency.
  • Invalid MSO Modes: Tests transmission of messages with invalid MSO locations for both airborne and ground link messages.
  • Doppler Test Mode: Generates Doppler frequency shifts for testing.
  • Modulation Frequency Mode: Adjusts eye diagram vertical spacing for MOPS requirements.
  • Receiver Selectivity Mode: Generates UST messages with specified frequency and power for selectivity testing.
Contact Information: For more details, contact VIAVI Solutions at +1 316 522 4981 or visit their website.
See more

Catalog excerpts

UAT 978 MHz Option-1

The UAT Option enables the UAT test capability which can be accessed from the Scenario Screen. UAT test capability allows the user to perform testing on their UAT receiver, including DO-282 MOPS testing. There are several UAT Test Modes of Operation tailored for the different types of DO-282 MOPS tests. For each UAT Test Mode of Operation, there is a common Setup Requirement as well as Common Capabilities. The UAT scenario requires a 1 PPS (One pulse per second) signal input in TX Mod #1 input on the back of the RGS2000NG to run the scenario. • Each channel allows 32 dynamic targets and 1500 static targets. Each target can be defined as an airborne or ground link message. • The user can modify the eye diagram horizontal spacing and also select different filters to change the transition in the eye diagram from positive to negative frequency deviation. • The targets can be defined in reference to an Own aircraft latitude and longitude, or as a specific offset from the Message Start Opportunity (MSO). The RGS-2000NG NextGen TCAS Test Set is designed for the following test applications: • Engineering development, certification, manufacturing and service • TCAS computers • ADS-B In Ground Station Receivers • ADS-R, TIS-B Ground Station Transmitters • Transponders Mode S/ADS-B Out (transponder option)

 Open the catalog to page 1
UAT 978 MHz Option-2

• Two transmitters or channels are available. UAT RX1 is connected to the top antenna and UAT RX2 is connected to the bottom antenna. • For Overlapping Mode, both internal transmitters are combined to the top antenna port allowing the user to perform the DO-282 MOPS tests associated with reception of overlapping UAT messages. • One UAT transmitter and one pulse modulated transmitter are combined internally to the top antenna port, allowing for the DME fruit DO-282 MOPS test to be run. • The power and frequency of the DME 12 |jS pulse pair can be selected by the user in this mode. • The user can...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.