Catalog excerpts
Static Control Product Catalog
Open the catalog to page 1Three Particular Reasons people choose VESSEL We have the best selection Vessel's lineup covers a wide range from fan, gun and bar-type air blow ionizers, EPA mats and wrist straps that prevent static discharge, to adhesive mats that prevent the scattering of dust. Our products provide solutions to your static removal and dust removal problems. aims for user friendliness To provide optimum products for production sites, our designs aim for ease of use. VESSEL aims for user convenience with our product lineup for various applications. dust removal specialists improve your quality problems...
Open the catalog to page 2the ionizing and dust elimination expert, helps solve your quality problems.
Open the catalog to page 3The static electricity comes from the transfer of electrons between two or more atoms becoming electrically unbalanced. electrons transfer The static electricity is created after contact between two materials (which at least one of them is an insulator). The static electricity level depends on humidity, materials, as well as on the pressure, the time, and the surface of contact. An electric voltage of several kV might be easily generated. ©Usually an object contains positive ions and negative ions. They are same in quantity and keep balance. ©When two objects come into contact, unstable...
Open the catalog to page 4Consequences Three types of problems can result from static electricity: • Apparition of electric arcs, which can damage the electronic circuits, • Dust attraction, which can lead to unwanted defaults after parts painting or cause hygiene and cleanliness problems, • And attraction or repulsion of other materials, which can cause, for instance, printing problems due to the repulsion of the ink or labeling problems due to the unwanted repulsion or attraction of the paper when being positioned. Dust attached on lenses, light guide panels Stacking error of plastic cups Film stiction error Resin...
Open the catalog to page 5Nozzle Type Mount on a cell workbench, part shelf or belt conveyor. Handle close to far distances <Wide width> Assemble Into manufacturing devices for pinpoint neutralization confined space. Just replace the nozzle to use with various neutralization after part acceptance and before part assembly, dust elimination from resin formed products before painting. Suitable for neutralizing clean rooms, and preventing static buildup on film moving at high <Built-in power supply> <Separate power supply>
Open the catalog to page 6Perform air washing within static electricity removal area. Scattered dust is collected with the dust collector to maintain a clean <Gel Dust Collection Type> <Dust Collection Chamber built-in Type> ESD control mats for use in areas where parts are handled, assembled, repaired and tested. Available in ESD control mats and wrist straps. Clean Walker Adhesive mat, set before a clean room, collects dust off soles of Options and replacement parts. work shoes. Non-peeling, washable type. <Separate Dust Collecter Type> <ESD Countermeasure Wrist Straps> <Surtace resistance checker> <Electrostatic...
Open the catalog to page 7Why is VESSEL'S fan type our customer's top choice? High neutralization performance through efficient ion generation The high frequency piezoelectric transformer generates large volumes of ions, and eliminates losses caused by recoupling. High-frequency piezoelectric transformer fPiezzoJ Advanced control technology with steady ion balance The capacity coupling type electrode needle ensures a stable ion balance, and prevents static destruction of the semiconductor. Louver cover improves The cover can be easily removed allowing the electrode needle to be cleaned where it will not contaminate...
Open the catalog to page 8► Easily remove louvers Confirm operation status and electrode tip contamination with built-in light. Remove clip when not needed Ionizing method/Applied voltage Power supply and current consumption Decay time Operating range Noise level Ozone production Operating environment temperature and humidity Easy removal Built-in light Piezoelectric high-frequency AC corona discharge/AC 3.5kV 5°C to 40°C/35% to 65% RH (with no dew condensation or freezing] Decay area
Open the catalog to page 9Fan-type Ionizer with Integrated Sensor Ion balance is monitored by a sensor
Open the catalog to page 10Wide-type Ionizer with Cross-flow Fan Compact, low-profile design saves space ► Maintains an ion balance of ±5 V using capacitive-coupled electrode needles. ► LED indicator lights up progressively to indicate airflow. ► LEDs all flash after 200 hours of operation to indicate cleaning time. volume adjustment knob electrode needles Ionizing method/Applied voltage Power supply and current consumption Decay time Operating range Noise level Ozone production Operating environment temperature and humidity Piezoelectric high-frequency AC corona discharge/AC p-p9kV O.OSppm or less (measured 50mm)...
Open the catalog to page 12Fan Type Nozzle Type Gun Type Bar Type VESSEL ionizers for a variety of applications. Static electricity removal in a bottle Production of the wafer film Cleaner Working Mat Clean Walker Options Dust prevention on molded parts Dust and/or static electricity removal from large resin parts Static electricity removal from films and/or products
Open the catalog to page 13Nozzle Type Why is VESSEL'S nozzle type our customer's top choice? indicate the operating status The bright LED lamps show the operating state even when installing in dark systems. Diverse lineup of optional nozzles support various applications Use the optional shower nozzle or silent nozzle. Daisy-chain the power cables to keep high-voltage cables inside Power can be supplied to multiple units by daisy-chaining them. 24 VDC wiring enhances safe connection.
Open the catalog to page 14<Tube fitting Nozzle and Shower Tube installed^
Open the catalog to page 15Why is VESSEL'S gun type our customer's top choice? The bright white LED lamp makes dust visible Use the LED lamp to check dust that has High discharge air blow ionizer Decay time Eliminate dust and static electricity Silent and highly durable Piezoelectric transformer enhances safety with no need to expose high-voltage cables The high-voltage cable is not exposed, so there's no need to worry about current leaks or electric shock caused by wire breakage. Ergonomically designed grip is easy to hold and adjusted to The nozzle direction faces the optimum direction when the grip is held,...
Open the catalog to page 16All VESSEL CO. catalogs and technical brochures
-
precision-bits
7 Pages
-
bit-holders
4 Pages
-
BITS & SOCKETS
32 Pages
-
technical-data 2017/2018
11 Pages
-
general-catalogue 2017-2018
240 Pages
-
Gasoline Engine Hammer Drill
2 Pages
-
General Catarog
4 Pages
-
Air nipper
32 Pages
-
Air tolls
56 Pages
-
industrial bit
36 Pages
-
Hand tool
58 Pages