Catalog excerpts
Encore Current to Voltage Transducer / Shunt Verivolt Encore is part of the Verivolt family of current to voltage transducers designed to measure isolated and ground currents. The main focus of the Encore family is to ease and accelerate measuring the output current from low voltage current sources as well as isolated current transformers (CT). Particular attention was paid on providing a solution that minimizes cost and improves overall performance on distributed systems such as substations, building monitoring, power distribution systems, etc. The Encore series covers the ranges of ±0.1A, ±1A, ±2A, ±3A, ±4A and ±5A with customizable bandwidth of up to 40kHz and 0.2% accuracy SPECIFICATION Eletronical Scaling Factor (1V output voltage) Overload Current (60Hz sinewave for 10s) Input impedance at 60Hz Output impedance HARDWARE DESCRIPTION Verivolt Encore 5c operates as a current to voltage shunt that generates a ±100mV range signal for it’s nominal input current range. This signal can then be processed by a computer based measurement platform. In conjunction with the EasyConnect family, the Encore is the ideal solution for high channel density applications Input-Output non-linearity Output voltage Gain temperature drift Phase mismatch Output type Single-ended signal Output impedance Output connector Functional Diagram of Encore Environmental< ±10μV Operating temperature Storage temperature Mounting example of Encore Input connector (1-Pin Coaxial) Outer Dimensions (Cylindrical shape) Due to its compact size and shape, the Encore can be easily mounted anywhere between the signal source and the data acquisition system. The versions up to 5A may even be used inline with the cable and not require any mounting at all. All can be secured to fixtures using cable ties. (1) Form factor can vary for customized solutions.
Open the catalog to page 1MERCHANICAL DIMENSIONS HARDWARE CONFIGURATION A. Connect BNC cable to sensor output. Make sure the BNC jack is connected to DAQ or at least properly grounded. B. Make sure Input Signal cable is de-energyzed to avoid arcing. Verify if input connectors are clean. Plug input signal into input connector of sensor. C. Secure sensor to avoid accidental disconnection during operation THIS SENSOR IS NOT A SAFETY DEVICE AND IS NOT INTENDED TO BE USED AS A SAFETY DEVICE. This sensor is designed only to detect and read certain data in an electronic manner and perform no use apart from that,...
Open the catalog to page 2All Verivolt catalogs and technical brochures
-
IsoBlock I-FG-4c
2 Pages
-
Entube QE
2 Pages
-
Encore
2 Pages
-
Entube SE
2 Pages
-
V2I
2 Pages
-
Entube Z
2 Pages
-
Esol TE-MV
2 Pages
-
IsoBlock Q-4c
2 Pages
-
Envoy SC
2 Pages
-
Entube DE
2 Pages
-
Entube DE-HB
2 Pages
-
Entube TE
2 Pages
-
IsoBlock C-4c
2 Pages
-
IsoBlock P-1c
2 Pages
-
IsoBlock I-FG-1c
2 Pages
-
IsoBlock V-4c
2 Pages
-
Entube DE-HB-S
2 Pages
-
IsoBlock C
2 Pages
-
IsoBlock V-1c
2 Pages
-
IsoBlock Q
2 Pages