PH/ORP, FREE ACTIVE CHLORINE,TEMPERATURE MEASURING & CONTROL INSTRUMENTS Chlorine (HOCI, HOBr or CI02) & Temperature Typical applications > Water quality control > Drinking water security > Industrial process control > Chemical dosing measurement > Swimming pool water quality > Real-time water network electrolyte maintenance > Chemical free operation Main features disinfection species: HOCI, HOBr > User replaceable sensing head "Compatible with Sensing Module Probes General description The KAPTA™ 2000 controller has been designed specifically for the industrial and water treatment markets and, coupled with the KAPTA™ 2000-AC2 chlorine and temperature probe, provides a rapid, accurate measurement of free chlorine. The controller is equipped with all the key functions required to provide the user with flexibility for set-up, measurement and control of systems from simple chlorine measurement and recording right through to industrial process control and chemical dosing. The KAPTA™ 2000 controller is capable of measuring chlorine, ORP, pH and temperature and is fitted with 2 current outputs, 4 relays and P.I.D. functionality allowing up to 6 external points to be measured or controlled. Operation of the controller is simple with a 128x64 pixel resolution graphic display providing continuous readout of chlorine / temperature measurement and status of the control output devices, selectable in a choice of 5 different languages (English, French, German, Italian and The controller is IP66 rated, wall mounted and equipped for RS485 serial port communication for remote monitoring and data storage. On-board software is designed for 2 point calibrations to ensure accuracy, reliable performance and sensor diagnostic information. Solutions & Technologies
Open the catalog to page 1PH/ORP, FREE ACTIVE CHLORINE, TEMPERATURE MEASURING & CONTROL INSTRUMENTS Chlorine (HOCI, HOBr or CI02) & Temperature Compatible with Sensing Module Probes Models: KAPTA™ 2000-AC2 R1_01_F1 and KAPTA™ 2000-AC2 R1_01_F2 Specifications (Controller) General specifications Measurement of free chlorine or active chlorine (HOCI), temperature (PT 1000) and pH (optional) Simultaneous display of chlorine and temperature Wall mounted Internal flash 4 Mbit memory Serial output RS485 modbus RTU 2 Programmable analogue outputs Sensor Inputs Analogue Inputs Digital Communication Relay Outputs Operating temperature...
Open the catalog to page 23 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
8 Pages
2 Pages
6 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
2 Pages
5 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
4 Pages
2 Pages
2 Pages
2 Pages
6 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages