Application
The LAUTUS air purifier is designed to clean air from particles of microorganisms, fungi, bacteria, and viruses larger than 0.1 μm in enclosed spaces such as reception desks, shops, pharmacies, offices, libraries, restaurants, and industrial spaces like mechanical workshops.
Construction
The device features copper grids at the inlet and in the sealed chamber between H13 and H14 filters to accelerate microorganism decomposition. It employs a 3-stage filtration system:
  • Stage I: G4 pre-filter captures dust and dirt.
  • Stage II: H13 filter removes microorganisms, bacteria, and fungi.
  • Stage III: H14 filter stops 99.995% of 0.1 μm particles, including viruses.
The sealed chamber includes a UV-C lamp that disintegrates microorganism cells. The lamp operates in one-hour intervals and meets the PN-EN 62471 standard for photobiological safety. The device has an intelligent control system for 4-stage airflow regulation and signals for pre-filter contamination, H14 filter unsealing, and UV-C lamp failure. It is constructed from painted aluminum and mounted on wheels for easy transport.
Electric Motor
The device uses highly efficient motors with integrated EC technology to reduce electricity demand and minimize operating costs.
Special Execution
Custom painting options are available in colors consistent with the RAL palette.
Filtration and Security
The filtration system is protected by copper partitions, and the UV-C lamp deactivates microorganisms.
Dimensions
LAUTUS 50: 600mm x 730mm x 700mm
LAUTUS 100: 750mm x 730mm x 850mm
Performance Curves
Graphs indicate noise levels and airflow at various rotation speeds for both LAUTUS 50 and LAUTUS 100 models.
Technical Characteristics
  • LAUTUS 50: Max airflow 450 m3/h, power 150 W, current 1.6 A, voltage 230 V, sound pressure 64 dB(A), weight 47 kg.
  • LAUTUS 100: Max airflow 800 m3/h, power 250 W, current 2.7 A, voltage 230 V, sound pressure 74 dB(A), weight 60.5 kg.
Sound pressure is measured at 1.5m from the fan at 2/3 of maximum airflow.
See more

Catalog excerpts

LAUTUS-1

LAUTUS air purifier APPLICATION Device is designed to clean air from particles of microorganisms, fungi, bacteria and viruses larger than 0,1 Μm in closed areas where people reside, as like: · reception desks, shops, pharmacies, offices, libraries, restaurants, as well as in industrial spaces such as mechanical workshops. On objects made of copper, the persistence of bacterias and viruses is significantly shorter. Due to this at the inlet of the device and in the sealed chamber between the H13 and H14 filters, copper grids were used to accelerate the decomposition of microorganisms. The device uses a 3-stage filtration level which consists of: · I - pre-filter in the G4*, class, located right behind the inlet, whose task is to catch dust particles and dirt from the air, · II - filter classified H13*, located behind the pre-filter and in front of the UV-C lamp, whose task is to filter the air from microorganisms, bacteria or fungi, · III - H14 class* filter that is able to stop 99.995% of 0.1 Μm particles such as viruses. The sealed chamber consists of H13 and H14 filters and a UV-C lamp. Inside the chamber, the radiation of the UV-C lamp disintegrates the cells of microorganisms effectively fighting them inside the device. The side panels use LEDs informing the user about the operation of the UV-C lamp. The lamp works in intervals of one hour irradiation to the chamber, next the lamp is turned off for the next hour. The device meets the requirements of the PN-EN 62471 standard regarding the photobiological safety of lamps. The intelligent control system allows for 4-stage airflow regulation. The device is equipped with signaling pre-filter contamination, unsealing of the H14 filter and failure of the UV-C lamp. The whole is a modern structure made of painted aluminum sheet mounted on wheels ensuring easy transport. H14 Cu H13 G4 Cu Special execution Painting in a color other than the standard one, consistent with the RAL palette. Filtration and security Filtration with three protected by copper partitions. · Highly efficient motors with integrated EC technology ensure reduced demand for electricity (lower CO2 emission), minimize operating costs. * The filtration efficiency of the filters used in the device is defined by the standards PN-EN 779, PN-EN 1822-1, PN-EN 1822-4 UV-C lamp The device is equipped with a UV-C lamp, which destroys and deactivates microorganisms.

 Open the catalog to page 1
LAUTUS-2

LAUTUS air purifier TECHNICAL CHARACTERISTICS Type sound pressure level* article number * sound pressure measured at a distance of 1,5m from the fan at q=2/3*qmax. PERFORMANCE CURVES LAUTUS 50 outlet connector * For the proper operation of these accessories, an outlet connector is required

 Open the catalog to page 2

All Ventur catalogs and technical brochures

  1. RF/EC

    11  Pages

  2. OZI

    2  Pages

  3. KABB / KABT

    6  Pages

  4. CAB B

    6  Pages

  5. CAB-PLUS

    6  Pages

  6. CAB ECOWATT

    8  Pages

  7. CAB

    11  Pages

  8. TD KIT

    13  Pages

  9. AFK

    6  Pages

  10. AFH

    3  Pages

  11. AFC-VB

    3  Pages

  12. AFW

    3  Pages

  13. VENT

    44  Pages

  14. TD ECOWATT

    55  Pages

  15. TD SILENT

    49  Pages

  16. REB - ECOWATT

    2  Pages

  17. RMB RMT

    11  Pages

  18. CTB

    44  Pages

  19. Serie COMPACT

    44  Pages

  20. HXM

    18  Pages

  21. CVB - CVT

    44  Pages

  22. TDx

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.