1. Catalogs
  2. Ventur
  3. JET FAN JFV, JFVR, JFSR

JET FAN JFV, JFVR, JFSR
1 /2Pages

JET FAN JFV, JFVR, JFSR

JET FAN JFV, JFVR, JFSR
1 /2Pages

Catalog excerpts

JET FAN JFV, JFVR, JFSR-1

JET FAN JFV, JFVR, JFSR axial jet fans APPLICATION Axial jet used to cause air movement in a closed parking, tunnels and large spaces. ∙∙ JFV and JFVR for general ventilation, with air temperature from -150C to +500C ∙∙ used in ventilation systems whose function is to remove contaminated air containing eg. carbon dioxide, nitrogen oxides, and sulfur. ∙∙ JFSR for general and smoke ventilation with an air temperature up to +4000C for up to 120 minutes - class F120400 ∙∙ the ventilation function is carried out during normal operation of the fans and consists in removing polluted air from ventilated spaces, ∙∙ smoke exhaust function is carried out in the event of a fire. The optimal fan system should be verified by means of CFD simulation, so that the entire system is designed in accordance with the requirements of the relevant standards and maintaining the architectural specificity of the given space. Axial jet fans type JFV, JFVR JFV, JFVR ∙∙ powder coated steel housing (RAL5010 - blue as standard), ∙∙ two galvanized mounting feet, ∙∙ unidirectional rotor is made of polypropylene, ∙∙ reversible monolithic rotor made of aluminium alloy, ∙∙ terminal box for electrical connection on the housing, ∙∙ as standard two silencers made of aluminium sheet, ∙∙ steel, painted protective mesh inlet and outlet (RAL5010), combined with a properly shaped aerodynamically flow-compensated confractor, ∙∙ four sizes: 315, 355, 400 and 450 in one and two speed versions, ∙∙ JFV are one-way fans, while JFVR are two-way (reversible). JFSR ∙∙ galvanized casing, ∙∙ two galvanized mounting feet, ∙∙ the rotor is entirely cast in aluminium, ∙∙ steel hub, galvanized, screwed with a paddle ring, ∙∙ terminal box for electrical connection on the housing, ∙∙ as standard two silencers made of aluminium sheet, ∙∙ galvanized protective mesh at the inlet and outlet (RAL5010), combined with a properly shaped aerodynamically flow confractor, ∙∙ four sizes: 315, 355, 400 and 450 in one and two speed versions, ∙∙ two-way (reversible). Axial jet fans for smoke extraction JFSR 1. Fan type JF – jet fan 2. Application S – smoke V – ventilation 3. R – reversible 4. Motor type and speed 2 – single speed, ~2900 rev./min 2/4 – two speed, ~2900/1450 rev./min 5. Nominal diameter 6. Nominal power supply 750W / 100 = 075 7. T – three-phase power supply 3x400V JFV, JFVR ∙∙ asynchronous, three-phase 400V 50Hz, one-speed 2-pole or two-speed 2/4-pole, ∙∙ degree of protection IP55, ∙∙ insulation class F. JFSR ∙∙ asynchronous, three-phase 400V 50Hz, one-speed 2-pole or two-speed 2/4-pole, ∙∙ degree of protection IP55, ∙∙ insulation class H. ∙∙ certificated in the temperature class F120400. Optional deflector on outlet. Galvanized steel deflect

 Open the catalog to page 1
JET FAN JFV, JFVR, JFSR-2

JET FAN JFV, JFVR, JFSR axial jet fans TECHNICAL CHARACTERISTICS Type maximum maximum calculated measured absorbed absorbed thrust thrust* power current sound pressure level** article number * thrust measured in accordance with PN-EN ISO 13350, ** sound pressure at 3m.

 Open the catalog to page 2

All Ventur catalogs and technical brochures

  1. RF/EC

    11  Pages

  2. OZI

    2  Pages

  3. LAUTUS

    2  Pages

  4. KABB / KABT

    6  Pages

  5. CAB B

    6  Pages

  6. CAB-PLUS

    6  Pages

  7. CAB ECOWATT

    8  Pages

  8. CAB

    11  Pages

  9. TD KIT

    13  Pages

  10. AFK

    6  Pages

  11. AFH

    3  Pages

  12. AFC-VB

    3  Pages

  13. AFW

    3  Pages

  14. VENT

    44  Pages

  15. TD ECOWATT

    55  Pages

  16. TD SILENT

    49  Pages

  17. REB - ECOWATT

    2  Pages

  18. RMB RMT

    11  Pages

  19. CTB

    44  Pages

  20. Serie COMPACT

    44  Pages

  21. HXM

    18  Pages

  22. CVB - CVT

    44  Pages

  23. TDx

    17  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.