AFW - 1

V abcdefgh abcdef Assembly-, Operation- and Maintenance Instructions, EC-declaration Axial Fans Type AFW The manual should always be available for the operating personnel. The instructions should be carefully read before installation and operation of the fan. If strict notice is taken of these instructions, the fans run with troublefree operating for years. With reservations for the right to make alterations. If doubtful, get in touch with the manufacturer. Table of contents A Technical data B Warranty C Safety D Installation E Start of operation F Maintenance G Spare parts list H Manufacturer declaration C Safety Following safety instructions must be carefully followed with regard to preventing injury or damage to surrounding equipment and to the fan itself. 1 Suction Warning! Axial fans have high suction power. Objects, clothing and hair can easily be sucked into the fan and cause injury. Make sure that there are no persons nearby the inlet side when the fan operates. Protection guard may be removed only if it is replaced with a house or pipe of at least 1m. The fan must never operate without a wire guard because the rotation impeller can cause serious injury. 2 Discharge side Warning! There is a powerful stream of air from the discharge side. Foreign bodies that might have been sucked into the fan can be thrown out at high speed and cause injury. Never put the hand directly at the discharge opening. 3 Temperature Warning! When the fan operates the fan housing takes the temperature of the conveyed media. If the fan casing temperature exceeds 50°C the fan must be protected from direct contact to prevent burn injury. 4 Electrical connection Warning! Electrical connection must be made by skilled labour only. The drive motor should be protected with an overload switch. A Technical Data Following data is for the fan in its basic form, however, delivered fan can differ from the basic form. See the mark sign or the text "Special execution". Fans type AFW have wall plate of powder coated steel sheet and an impeller of polyamide reinforced with anchored fibreglass, and should only be used for conveying clean media. AFW fans may be delivered with protection net as accessory. The temperature of the conveyed medium may not exceed 40°C. It is not permitted to use the fan in surroundings where the temperature exceeds 40°C or goes below -20°C. Conveying of explosive gases is not permitted. It is not permitted to rebuild or in any other way modify the fan. Special features that can be used in other surroundings than above can be offered on request and clarification with the manufacturer. Rating plate 5 Permitted applications Warning! AFW-fans are not to be used for conveying aggressive, toxic or air with high humidity or gas or explosive air-gas mix. 6 Sound level The sound pressure level is not the same over the whole range on the fans. In some cases it is necessary to use a silencer. We recommend the user to check the sound pressure level. D Installation 1 Transportation Check all parts for damage during transportation and that the impeller runs free inside the housing. The blowers are to be installed in weather-protected places and are not to be stored unprotected outdoors. Mount hoisting hook carefully, and do only use lifting arrangements with sufficient strength. 2 Arrangements and assembling Mount the fan horizontally or vertically in a weather-protected place. Make sure that the fan is protected from vibration and shock. Supply open inlet and discharge openings with guards according to valid regulations. Make sure that the drive motor is supplied with sufficient ventilation. The permitted maximum temperature of surroundings is 40°C. tekniska AB Göteborg Stockholm Sweden Fan type: IP: Mot type: kW V ∆/Y Hz A cos Φ: Isol.-Cl. rpm No: Art.nr: When connecting, maintenance or ordering of spare parts, pay attention to data on the mark sign in first instance. Special execution EEx motors, housing and impeller in other materials, can be delivered on request and after clarification with the manufacturer. 3 Electrical connection Attention! The operations described in this part are to be made by skilled labour only. Connect the fan in accordance with the wiring diagram in the terminal box. The respective VDE regulations and the directions of the local power supply company are to be complied with. The fan is equipped with a drive motor for single- and three-phase AC. The motor should be protected with an overload switch. Connection to earth is to be found in the terminal box. B Warranty Warranty is valid in accordance with General Conditions Orgalime S2000 and only if these instructions are strictly adhered to. 2 Version V-6.1 © Ventur tekniska ab 2010 Version V-6.1 © Ventur tekniska

Open the catalog to page 1
AFW - 2

Manufacturer declaration Connection of three-phase AC unit W2 (high voltage Y-connection) EC Declaration of conformity for machinery (Machinery Directive 2006/42/EC, Annex 2, A) Connection of single-phase AC unit Manufacturer: Ventur tekniska ab Manufakturgatan 7 A SE-417 07 GÖTEBORG Sweden Name and address of the person authorised to compile the relevant technical file: Name: Peter Skoow Address: See above Herewith declares that: Axial Fans Type AFW ● is in conformity with the relevant provisions of the Machinery Directive (2006/42/EC) Z2 ● is in conformity with the provisions of the...

Open the catalog to page 2
AFW - 3

Spare Parts List 3 Protection Net Motor side

Open the catalog to page 3

All Ventur catalogs and technical brochures

  1. RF/EC

    11 Pages

  2. OZI

    2 Pages

  3. LAUTUS

    2 Pages

  4. KABB / KABT

    6 Pages

  5. CAB B

    6 Pages

  6. CAB-PLUS

    6 Pages

  7. CAB ECOWATT

    8 Pages

  8. CAB

    11 Pages

  9. TD KIT

    13 Pages

  10. AFK

    6 Pages

  11. AFH

    3 Pages

  12. AFC-VB

    3 Pages

  13. VENT

    44 Pages

  14. TD ECOWATT

    55 Pages

  15. TD SILENT

    49 Pages

  16. RMB RMT

    11 Pages

  17. CTB

    44 Pages

  18. Serie COMPACT

    44 Pages

  19. HXM

    18 Pages

  20. CVB - CVT

    44 Pages

  21. TDx

    17 Pages