Group: VELP
Catalog excerpts
Dual Carrier Gas Nitrogen Analyzer Analysis in a Flash with the VELP Nitrogen/Protein Analyzer - Can operate with Argon or Helium as carrier gas - Fully Automated: totally unsupervised and independent of user’s capabilities - Flexible and Versatile: optimal for several sorts of sample - High Productivity: non-stop performance and moderate running costs NDA 702 is a new conception nitrogen/protein Dumas analyzer, ensuring excellent performance on both solid and liquid samples and equipped with the TEMS™ technology: Time Saving - Unparalleled technology, results in 3-4 minutes. Energy Saving - Excellent engineering, low consumption. Money Saving - Limited cost per analysis, less gas and reagents used (LoGas™ and DriStep™). Space Saving - Just one slim unit required for the whole analysis. NDA 702 is designed to last and to operate continuously, even 24/7, whilst providing a very low detection limit (0.001 mg N, when using Helium) and superlative precision. The instrument includes an autosampler that can manage up to 30 samples (stackable to 117). NDA 702 gives the possibility to choose between Helium or Argon, without the need for replacing any part. After years of increasing prices and supply chain interruptions, obtaining Helium, the conventional carrier gas, has become more and more difficult and expensive, especially in some countries. The desire to replace Helium with a more easily accessible carrier gas has intensified and become reality. NDA 702 benefits go further, as the dedicated software DUMASoft™ has been improved for a clearer communication and enhanced control, including some new features, being now multi-lingual (languages downloadable), offering average, SD, RSD without the need to create a report, temperature and pressure in different formats (°C/°F and bar/psi), plus assign-name function on calibratio
Open the catalog to page 1In the Dumas combustion method, the encapsulated sample is burnt at a high temperature, in the presence of catalysts in a controlled oxygen atmosphere. The combustion gas, CO2, H2O, NOx, passes through the reduction furnace where NOx are reduced to N2. The H2O and CO2 are separated and the elemental nitrogen is measured with a Thermal Conductivity Detector (TCD). The whole procedure takes from 3 to 4 minutes. The samples need to be suitably homogenized, in order to maximize results’ precision and to analyze a representative part. NDA 702 Analysis Flowpath HELIUM or ARGON as carrier gas on...
Open the catalog to page 2All VELP catalogs and technical brochures
-
UDK Series - Distillation Units
10 Pages
-
MULTI-HS Series
2 Pages
-
MSL 50 Digital
2 Pages
-
MSL 25 Digital
2 Pages
-
MSL 8
2 Pages
-
FIWE ADVANCE
6 Pages
-
RESPIROMETRIC Sensor
6 Pages
-
FOC 200I Connect
2 Pages
-
FOC 120I Connect
2 Pages
-
FOC 120E Connect
2 Pages
-
FIWE
2 Pages
-
AM4 Digital PRO
2 Pages
-
FOC 200IL Connect
2 Pages
-
FOC 200E
2 Pages
-
OCB Open Circulating Bath
2 Pages
-
MULTISTRIRRER Digital
2 Pages
-
Cooled Incubators
2 Pages
-
ECO COD Thermoreactors
2 Pages
-
DKL Digesters Series
4 Pages
-
CLASSIC Vortex Mixer
2 Pages
-
BOD SENSOR
2 Pages
-
BOD EVO SENSOR
2 Pages
-
DK 20 and DK 42/26
2 Pages
-
OHS Digital & Advance Series
2 Pages
-
AREX-6 Connect PRO
2 Pages
-
CN 802
6 Pages
-
HU 6 Hydrolysis Unit
2 Pages
-
NDA
4 Pages
-
AREC.X
2 Pages
-
ARE/AREX-6 Series
6 Pages
-
AREC.T
2 Pages
-
AREX Digital PRO
2 Pages
Archived catalogs
-
VELP Scientifica
20 Pages
-
VELP Company Brochure
18 Pages
-
Velp Catalogue 2008/2009
102 Pages