Overview: This document provides step-by-step instructions for installing a magnetic encoder onto a Velmex BiSlide® system. The process involves attaching a reading head sensor, mounting brackets, and applying magnetic tapes.
Specifications and Supplies Required:
  • Elgo Magnetic Linear Encoder
  • Velmex BiSlide
  • Two 6-32 x 3/8 pan head screws
  • Two 6-32 x 3/8 SHCS screws
  • Isopropyl alcohol
  • Super Glue®
Installation Procedure:
  1. Attach the reading head sensor to the reading head bracket using the provided screws.
  2. Mount the reading head bracket to the side of the BiSlide carriage.
  3. Lay the BiSlide unit on its side carefully to avoid damaging the limit switches.
  4. Move the carriage to the end of the BiSlide until it stops at the limit.
  5. Lay the Magnetic Flexible Tape on the second rib from the top of the BiSlide body, ensuring it extends 1/4” past the sensor.
  6. Mark the rib at both ends of the magnetic tape.
  7. Remove the reader head bracket and clean the rib with isopropyl alcohol.
  8. Apply a small drop of Super Glue at the marked ends of the rib.
  9. Peel back the sticky tape backing and press the magnetic tape down, keeping it centered on the rib.
  10. Continue applying the tape towards the motor end, holding it down for 30 seconds at both ends.
  11. Repeat the process for the Magnetic Permeable Steel Tape, applying glue on the magnetic tape ends.
  12. Reattach the reader head bracket and sensor, leaving screws loose.
  13. Use shim stock to gap the distance between the magnetic tape and the sensor for optimal performance.
Important Notes:
  • Ensure the sticky and magnetic tapes are correctly positioned as they cannot be repositioned once applied.
  • Two people may be required for longer installations.
See more

Catalog excerpts

Attaching Magnetic Encoders to BiSlide 714-1

Instructions to install ELGO Magnetic Linear Encoder on to Velmex BiSlide® Supplies Required: • Elgo Magnetic Linear Encoder • Velmex BiSlide • Two 6-32 x 3/8 pan head screws (included hardware) Installation Instructions Refer to Diagram 1 1. Attach reading head sensor to reading head bracket using 6-32 x 5/8 SHCS, provided. 2. Mount reading head bracket to the side of the BiSlide carriage using 6-32 x 3/8 pan head screws, provided. 3. Carefully lay the BiSlide unit on its side without damaging the limit switches. 4. Move/run carriage down to end of BiSlide with yellow bushing until it reaches the limit and stops. 5. To attach Magnetic Flexible Tape (A / B): Lay the magnetic tape (A / B) down on the 2nd rib down from top of BiSlide body underneath the reading head bracket with it extending 1/4” past the sensor. 6. Mark the BiSlide rib at both ends of the magnetic tape. 7. Remove reader head bracket. 8. Clean rib with Isopropyl alcohol without removing marks. 9. At both ends of the rib where the marks are, put a small drop of Super Glue. 10. At one end, peel back one inch or more of sticky tape backing. 11. Start by pressing end of magnetic tape down at the mark keeping it centered on the rib. This is important so that sensor will read properly. 12. Continue peeling tape backing as you push down and work your way toward the motor end of the BiSlide unit. 13. Hold down the magnetic tape at both ends for 30 seconds. 14. To attach Magnetic Permeable Steel Tape (C): Repeat steps 8-13, except wipe magnetic tape (A / B now attached to the BiSlide) with Isopropyl alcohol and put the small drop of glue on the magnetic tape (A/B) at the ends. 15. Attach reader head bracket, and reading head sensor using screws provided, leaving screws loose on sensor. 16. Using a piece of shim stock .012 - .017 to properly gap the distance between magnetic tape and reading head sensor. This gap must be correct for optimum performance. Two 6-32 x 3/8 SHCS (included hardware) Isopropyl alcohol Super Glue® Attach sensor to reading head Mount reading head to side of BiSlide Carefully turn the BiSlide on its side. Press the strip down keeping it centered on the rib. (11) NOTE: Once sticky tape and magnetic tape are applied they cannot be removed and repositioned, so make sure they are properly installed the first time. Two people may be required for longer applications. V£LM£X. INC Velmex, Inc. 7550 State Routes 5 & 20 Bloomfield, NY 14469-9389 www.velmex.com [email protected] Positioning Systems for Science and Industry

 Open the catalog to page 1

All VELMEX, Inc. catalogs and technical brochures

  1. Velmex Catalog

    149  Pages

  2. UniSlide

    16  Pages

  3. BISlide Catolog

    16  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.