Catalog excerpts
VENT VALVE VVV01 Veljan Vent valve VVV01 are electrically operated 3/2 way devices and are compatible Port Z - Power component with VELJAN pilot operated pressure controls and 2-way seat valves. Due to sandwich X Y Loaded : Solenoid OFF design, these vent valves can be easily installed into existing valves. No extra components Unloaded : Solenoid ON such as subplates, fittings and piping are required. Z PC VVV01 sandwiched between the power component or main body and the pilot section or cap of the valve it is controlling, directs the pilot oil to the power component to allow its Loaded : Solenoid ON designated function at system pressure, or to the pilot oil return to allow unloading. Two Y X Unloaded : Solenoid OFF different control spools are available for the functions. These are for ”Power component Z unloaded in normal position” and “Power component unloaded in switch position”. Solenoids are with manual override and leakproof function. Coils can be changed without interfering with the hydraulic circuit. SPECIFICATIONS General Type Mounting position : : Port sizes (nominal) : Ambient temperature : Special working conditions : 3/2 - Vent Valve Optional but horizontal recommended Identical with VELJAN Pilot Valve series VR4, VR5,VD4S and VCAR -20° C...+ 60° C ( -4° F...+140° F) Consult VELJAN X Y Z Hydraulics Pressure control range -Port X (pilot) -Port Y (drain) Nominal flow gpm (lpm) Fluid Temperature Range : : : : Optimum operating viscosity Overlap : : 5000 psi (350 bar) 2030 psi (140 bar) 1.0 ( 3.8 ) - 18° C...+ 80° C (0° F...+ 176°o F) 30 cSt (180 SSU) Positive : : : : : : : : : : By Solenoid AC or DC Refer to Ordering Code +5%...-10% +155° C (311° F) 31 W 78 VA 264 VA 100% I P 65 VVV01 + VR4V06 Actuation 20 Leakage VVV01 - 32 15 Leakage ml/min Electric Type of current Nominal voltage Permissible voltage fluctuation Max. coil temperature Input power Holding Inrush Relative operating period Type of protection 10 n ositio ch p Swit Normal position 5 0 Response time Solenoid energized Solenoid de-energized Cycle : : : : AC 20 ms 18 ms ...7200 /h DC 46 ms 27 ms ...16000 /h 0 50 100 150 200 250 300 350 Pressure bar 97
Open the catalog to page 1VENT VALVE VVV01 ORDERING CODE VVV01 - 3 1 1 - W07 - D - 1 Series PC Seal Class Type 3 - 3- way model 1- Buna N (Standard) Spool position 5 - Viton X 1 - Normal position : free flow from Z to Y switch position : X to Z 2 - Normal position : X to Z Switch position : free flow from Z to Y X Y Design letter D - AC Solenoid E - DC Solenoid Z Y Z Control Solenoid Voltage 1 - plug - in - type solenoid with manual over-ride 2 - plug - in - type solenoid without manual over-ride D - Pneumatic On request Q -Hydraulic W01 W02 W06 W07 - 115V/60 230V/60 115V/50 230V/50 Hz Hz Hz Hz GOR - 12V DC GOQ -...
Open the catalog to page 2All Veljan Hydrair Limited catalogs and technical brochures
-
Hydraulic Filters
46 Pages
-
VT7QDCC
3 Pages
-
VR5V06 Series
8 Pages
-
VR5U08 Series
8 Pages
-
VR4R series
8 Pages
-
E Series
7 Pages
-
Gear Pump - D Series
7 Pages
-
Hydraulic Filters Catalogue
46 Pages
-
Gear Pump - C Series
7 Pages
-
Gear Pump - B Series
6 Pages
-
V4DO1
13 Pages
-
V4DO2
14 Pages
-
V4DO6
16 Pages
-
VR4V
8 Pages
-
VT7QDCB
3 Pages
-
VT6CC
2 Pages
-
VT7DSW
2 Pages
-
VTXB
3 Pages
-
VJ
13 Pages
-
VCC
6 Pages
-
VSD
6 Pages
-
VIC
7 Pages
-
ILV 750
7 Pages
-
ILV 725
7 Pages
-
ILV 720
9 Pages
-
ILV 714
9 Pages
-
Hydraulic Cylinders
23 Pages
-
System Saver - Single Vane Pump
17 Pages
-
VT67EDC
3 Pages
-
VT67DDCS
3 Pages
-
VT67DCC
3 Pages
-
VT67EC
2 Pages
-
VT67BB
2 Pages
-
VT6CB
3 Pages
-
VT6BB
4 Pages
-
VTXBB
4 Pages
-
VD4S06
14 Pages
-
VD4S03
12 Pages
-
VDRV7 - VDV7 06 ? 08
6 Pages
-
VR5S06
8 Pages
-
VR4S03
8 Pages
-
VR4U10
9 Pages
-
VR5V12
8 Pages
-
VRIEO2
5 Pages
-
VT7EE/VT7EES
2 Pages
-
VT6EDCR
3 Pages
-
VT6DCCR
3 Pages
-
VT6CRM
2 Pages
-
VT6CR
2 Pages
-
J9V045
15 Pages
-
J9V009
7 Pages
-
VM4E
2 Pages
-
VM4D
2 Pages
-
VM4C
2 Pages
-
VM3B
2 Pages
-
System Saver
17 Pages
Archived catalogs
-
VELJAN HYDRAULIC PRODUCTS
11 Pages