VT67DCC

VT67DCC

VT67DCC

Product catalog summary

Overview

This document provides detailed technical specifications, operating characteristics, and installation guidelines for the VT67DCC high-performance vane pump series. It includes volumetric displacement data, mounting options, shaft types, seal classes, performance curves, and operational limits.

1. Volumetric Displacement Specifications

The pump series offers a range of volumetric displacements measured in cm³/rev and in³/rev. Key displacement values include:

  • B17: 55.0 cm³/rev (3.36 in³/rev)
  • B31: 99.1 cm³/rev (6.05 in³/rev)
  • B24: 81.1 cm³/rev (4.95 in³/rev)
  • B42: 137.5 cm³/rev (8.39 in³/rev)
  • 050: 158.0 cm³/rev (9.64 in³/rev)

Additional displacements range from 003 (10.8 cm³/rev) to 031 (99.9 cm³/rev), allowing selection based on flow and pressure requirements.

2. Mounting and Shaft Options

The pump supports multiple mounting flanges and shaft types:

  • Mounting flange: SAE J744c with 2 or 4 bolt options.
  • Shaft types: Splined (SAE CC) and keyed shafts, with clockwise (R) or counter-clockwise (L) rotation.
  • Seal classes: S1 for mineral oil, S4 for fire-resistant fluids, and S5 for mineral oil and fire-resistant fluids.
  • Design letters: Standard (00) and modifications available.

3. Operating Characteristics

Operating data is provided for typical conditions at 24 cSt viscosity and 1800 rpm, including input power (kW), flow rates (lpm/gpm), and pressure ratings:

  • Maximum recommended pressures vary by displacement size, e.g., 042-045-050 models max at 2200 rpm and 210 bar (3000 psi).
  • Specific warnings include avoiding use of the 003 displacement at 275 bar (4000 psi) and 1500 rpm due to excessive internal leakage (>50% theoretical flow).
  • Power loss and internal leakage curves are provided for various speeds (1200, 1800, 2400 rpm) and viscosities (10 cSt, 24 cSt).

4. Performance Limits and Recommendations

  • Maximum axial load permissible: 800 N (180 lbs).
  • Do not operate the pump for more than 5 seconds at any speed or viscosity if internal leakage exceeds 50% of theoretical flow.
  • Total leakage is the sum of losses from each section under operating conditions.
  • Noise levels are specified for triple pump configurations at various pressures.

5. Mechanical and Installation Details

Detailed mechanical dimensions and mounting torque specifications are included:

  • Mounting torque values range from 59 ft-lbs (80 Nm) to 162 ft-lbs (220 Nm) depending on bolt size and flange type.
  • Shaft dimensions and spline details conform to SAE standards (Class 1-J498b).
  • Keyed shaft and splined shaft options with precise measurements for fit and pressure angle.

6. Porting and Connection Variables

Port sizes and combinations are specified for P1, P2, and P3 ports with metric and UNC thread options. Direction of rotation is defined by viewing the shaft end.

Critical Notes and Limitations

  • Use caution with the smallest displacement (003) at high pressure and speed due to leakage concerns.
  • Adhere strictly to maximum rpm and pressure limits for each displacement size to avoid damage.
  • Ensure correct seal class selection based on fluid type to maintain pump integrity.

Summary

The VT67DCC vane pump series offers versatile volumetric displacements and mounting options suitable for high-performance hydraulic applications. Proper selection of displacement, shaft type, seal class, and operating parameters is essential to optimize performance and longevity. The document provides comprehensive data on flow, power, leakage, noise, and mechanical installation to guide engineers in pump specification and integration.

See more

Catalog excerpts

VT67DCC-2

HIGH PERFORMANCE VANE PUMP VT67DCC INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL) Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is more than 50 of theoretical flow. Total leakage is the sum of each section loss at its operating Triple pump noise level is given with each section discharging at the pressure noted on the curve. HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD Maximum axial load permissible Fa=800N (180 Lbs) Total hydromechanical power loss is the sum of each section at its operating conditions.

 Open the catalog to page 2

All Veljan Hydrair Limited catalogs and technical brochures

  1. VT7QDCC

    3  Pages

  2. VR5V06 Series

    8  Pages

  3. VR5U08 Series

    8  Pages

  4. VR4R series

    8  Pages

  5. E Series

    7  Pages

  6. V4DO1

    13  Pages

  7. V4DO2

    14  Pages

  8. V4DO6

    16  Pages

  9. VR4V

    8  Pages

  10. VT7QDCB

    3  Pages

  11. VT6CC

    2  Pages

  12. VT7DSW

    2  Pages

  13. VTXB

    3  Pages

  14. VJ

    13  Pages

  15. VCC

    6  Pages

  16. VSD

    6  Pages

  17. VIC

    7  Pages

  18. ILV 750

    7  Pages

  19. ILV 725

    7  Pages

  20. ILV 720

    9  Pages

  21. ILV 714

    9  Pages

  22. VVV01

    2  Pages

  23. VT67EDC

    3  Pages

  24. VT67DDCS

    3  Pages

  25. VT67EC

    2  Pages

  26. VT67BB

    2  Pages

  27. VT6CB

    3  Pages

  28. VT6BB

    4  Pages

  29. VTXBB

    4  Pages

  30. VD4S06

    14  Pages

  31. VD4S03

    12  Pages

  32. VR5S06

    8  Pages

  33. VR4S03

    8  Pages

  34. VR4U10

    9  Pages

  35. VR5V12

    8  Pages

  36. VRIEO2

    5  Pages

  37. VT7EE/VT7EES

    2  Pages

  38. VT6EDCR

    3  Pages

  39. VT6DCCR

    3  Pages

  40. VT6CRM

    2  Pages

  41. VT6CR

    2  Pages

  42. J9V045

    15  Pages

  43. J9V009

    7  Pages

  44. VM4E

    2  Pages

  45. VM4D

    2  Pages

  46. VM4C

    2  Pages

  47. VM3B

    2  Pages

  48. System Saver

    17  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.