VEGAPULS 6X

VEGAPULS 6X
1 / 20 PagesView full catalog

VEGAPULS 6X

Product catalog summary
Overview
The VEGAPULS 6X is a radar sensor designed for continuous level measurement in both liquids and bulk solids. It is suitable for use in small tanks, tight spaces, and vessels with complex installations, offering maintenance-free operation and high plant availability due to its non-contact measuring principle.
Technical Data
The sensor can measure up to 120 meters with a deviation of ≤ 1 mm. It operates on multiple frequency bands and supports various process fittings and pressures. It functions within a wide temperature range and offers multiple output signals, including 4-20 mA/HART, Profibus PA, Foundation Fieldbus, and Modbus.
Functional Principles
The radar sensor emits a high-frequency signal that reflects off the medium surface and is received back as an echo, which is processed to determine the level. It is suitable for measuring both liquids and bulk solids, with different antenna systems available for various applications.
Instrument Selection
The document provides guidance for selecting the appropriate antenna version based on application requirements, such as storage tanks and stirrer vessels.
Measuring Range Dimensioning for Liquids
Guidelines are provided for dimensioning the measuring range in various vessel types, considering factors like dielectric constant and antenna type.
Housing Overview
The VEGAPULS 6X is available in different housing materials, including plastic, aluminum, and stainless steel, each suited for specific environmental conditions.
Electronics
The device supports two-wire and four-wire configurations with various communication protocols and offers options for wireless adjustment via Bluetooth and remote systems.
Specifications
Operating voltage varies by configuration, ranging from 8 to 253 V DC/AC. Proper installation, grounding, and shielding are emphasized to ensure optimal performance and compliance with standards.
Procedures
Installation and configuration guidelines are provided, including compliance with standards like DIN EN 61140 VDE 0140-1 and EN 61326-1.
Norms and Standards
Compliance with DIN EN 61140 VDE 0140-1 for separation between supply and mains circuits and EN 61326-1 for shielding and grounding practices.
Recommendations
Use shielded cables in high-interference environments and ensure installations adhere to protocol specifications.
Connection Configurations
Detailed diagrams and instructions for connecting voltage supply, signal output, and grounding terminals for various protocols.
Adjustment Procedures
Includes direct, wireless, and remote adjustment options, utilizing various interfaces and modules for parameterization.
Safety Concept
Focuses on risk reduction through functional safety, adhering to IEC 61508 and 61511 standards, and IT security aligned with IEC 62443-4-2 standards.
Dimensions
Provides detailed measurements for various VEGAPULS 6X configurations.
See more

Catalog excerpts

VEGAPULS 6X-1

Product information Radar Level measurement in liquids and bulk solids VEGAPULS 6X

 Open the catalog to page 1
VEGAPULS 6X-2

Please note the Ex specific safety information which you can find on our homepage www.vega.com/downloads under " Approvals" and which comes with every instrument. In hazardous areas you should take note of the corresponding regulations, conformity and type approval certificates of the sensors and power supply units. The sensors must only be operated on intrinsically safe circuits. The permissible electrical values are stated in the certificate. Take note of safety instructions for Ex

 Open the catalog to page 2
VEGAPULS 6X-3

Application area VEGAPULS 6X is a radar sensor for continuous level measurement of liquids and bulk solids. The small process fittings offer particular advantages for liquids in small tanks or tight mounting spaces. The very good signal focusing ensures the use in vessels with many installations such as stirrers and heating spirals. For bulk solids under most different process conditions, the device is ideal for level measurement in very high silos, large bunkers and segmented vessels. The VEGAPULS 6X is equipped with an encapsulated plastic antenna or a lens antenna integrated into the metal...

 Open the catalog to page 3
VEGAPULS 6X-4

Technical data 2 Technical data VEGAPULS 6X Deviation, depending on the version Beam angle, depending on antenna Measuring frequency W-band (80 GHz technology) C-band (6 GHz technology) K-band (26 GHz technology) Process fitting Mounting strap Compression flanges from DN 80, 3" Thread from G¾, ¾ NPT Flanges from DN 20, ¾" Plastic plated flanges from DN 50, 2" Flanges with swivelling holder from DN 100, 4" Process pressure Process temperature Ambient, storage and trans- -40 … +80 °C (-40 … +176 °F) port temperature Operating voltage Output signal Foundation Fieldbus Modbus Bluetooth standard Display...

 Open the catalog to page 4
VEGAPULS 6X-5

Functional principles Thread with integrated antenna system Measuring principle Measuring principle radar technology The device transmits a high-frequency radar signal via its antenna. The emitted signal is reflected by the medium surface and received by the antenna as an echo. The difference between the emitted and the received signal is determined by special algorithms in the sensor electronics and converted into the level. Measured products Sensors in 80 GHz technology are suitable for continuous level measurement of liquids. The small process fittings offer particular advantages in small...

 Open the catalog to page 5
VEGAPULS 6X-6

Instrument selection 4 Instrument selection Application Antenna version Plastic horn antenna Filling vessels Measurement in the bypass tube Vessel/Collecting basin Plastic tank (measurement through vessel ceiling) Transportable plastic tank (IBC) Gauge measurement in waters Flow measurement flume/Overfall Pumping station/Pump shaft Overflow basin Silo (slender and high) Bunker (large-volume) Bunker with fast filling Heap (point measurement/profile detection) Simple process conditions Difficult process conditions Aggressive liquids Bubble or foam generation Wave movements at the surface Power...

 Open the catalog to page 6
VEGAPULS 6X-7

Measuring range dimensioning for liquids 5 Measuring range dimensioning for liquids 5.1 Vessel Applications Storage tank Storage tank with product circulation Stirrer vessel Flange with plastic plating Horn antenna Measurement tubes Surge pipe Flange with plastic plating Horn antenna Free radiating radar possible,

 Open the catalog to page 7
VEGAPULS 6X-8

Housing overview 6 Housing overview Plastic PBT Protection rating Single chamber Double chamber Application area Industrial environment Industrial environment Protection rating Single chamber Double chamber Application area Industrial environment with increased mechanical stress Industrial environment with increased mechanical stress Protection rating Single chamber, electropolished Single chamber, precision casting Double chamber, precision casting Application area Aggressive environment, food processing, pharmaceutical Aggressive environment, extreme mechanical stress Aggressive environment,...

 Open the catalog to page 8
VEGAPULS 6X-9

Electronics - Two-wire 4 … 20 mA/HART 7 Electronics - Two-wire 4 … 20 mA/HART Configuration of the electronics The plug-in electronics is mounted in the electronics compartment of the instrument and can be exchanged by the user when servicing is required. The electronics is completely encapsulated to protect against vibration and moisture. Connection, double chamber housing The terminals for voltage supply as well as the contact pins with I²C interface for parameter adjustment are located on the upper side of the electronics. In the double-chamber housing, the terminals are located in the separate...

 Open the catalog to page 9
VEGAPULS 6X-10

Electronics - Two-wire 4 … 20 mA/HART, with integrated radio module PLICSMOBILE 81 8 Electronics - Two-wire 4 … 20 mA/HART, with integrated radio module PLICSMOBILE 81 Configuration of the electronics The plug-in electronics is mounted in the electronics compartment of the instrument and can be exchanged by the user when servicing is required. The electronics is completely encapsulated to protect against vibration and moisture. Connection - radio module PLICSMOBILE 81 SIM Status The terminals for voltage supply as well as the contact pins with I²C interface for parameter adjustment are located...

 Open the catalog to page 10
VEGAPULS 6X-11

Electronics - Four-wire 4 … 20 mA/HART 9 Electronics - Four-wire 4 … 20 mA/HART Connection double chamber housing - mains voltage power supply Voltage supply Operating voltage with version for low voltage –– 9.6 … 48 V DC, 20 … 42 V AC, 50/60 Hz • Operating voltage with version for mains voltage –– 90 … 253 V AC, 50/60 Hz If a reliable separation is required, the power supply and the current output are transmitted over separate two-wire connection cables. The contact pins with I²C interface for parameter adjustment are located on the upper side of the electronics. The terminals for the power...

 Open the catalog to page 11
VEGAPULS 6X-12

10 Electronics - Profibus PA Electronics compartment, double chamber housing Voltage supply The voltage supply is provided by a Profibus DP /PA segment coupler. Specifications of the voltage supply: The terminals for voltage supply as well as the contact pins with I²C interface for parameter adjustment are located on the upper side of the electronics. In the double-chamber housing, the terminals are located in the separate terminal compartment. The plug-in electronics is mounted in the electronics compartment of the instrument and can be exchanged by the user when servicing is required. The electronics...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.