Specification sheet VEGAMET 862
2Pages

{{requestButtons}}

Catalog excerpts

Specification sheet VEGAMET 862 - 1

Specification sheet Controller in field housing for two continuously measuring digital or analogue level sensors Technical data Operating voltage ƲƲ Nominal voltage AC ƲƲ Nominal voltage DC Power consumption Application area The VEGAMET 862 controller feeds the connected 4 … 20 mA or HART sensors, processes the measured values and displays them. A large display for data visualisation is integrated in the housing designed for rough field conditions. It enables simple implementation of pump controls, flow measurements on open channels and weirs, totalizers, data loggers, difference, sum and average value calculations. With VEGAMET 862, limit values can be reliably monitored and relays can be switched, e.g. for an overfill protection according to WHG. Your benefit • Easy-to-read display from a distance, even in sunlight and darkness Sensor input Number of sensors 2 x 4 … 20 mA/HART Type of input (selectable) ƲƲ Active input Sensor supply through VEGAMET 862 ƲƲ Passive input Sensor has an own voltage supply Measured value transmission ƲƲ 4 … 20 mA analogue for 4 … 20 mA sensors ƲƲ HART protocol digital for HART sensors Terminal voltage 27 … 22 V at 4 … 20 mA Digital input Quantity Input type active ƲƲ Voltage ƲƲ Current Input type passive ƲƲ Switching threshold Low ƲƲ Switching threshold High • Complex programming of control tasks is no longer necessary Relay output Quantity • Secure measurement data memory on SD card Switching voltage Switching current Breaking capacity • Simple and reliable commissioning and diagnosis of the measuring points via smartphone Function The VEGAMET 862 controller can power the connected sensors and process their measurement signals. The requested parameter is shown on the display and also output to the integrated current output for further processing. The measurement signal can thus be transferred to a remote display or a superordinate control system. Operating relays for control of pumps or other devices are also integrated. Current output Quantity Range Max. load Bluetooth interface Bluetooth standard 6 x operating relay, one can be configured as fail safe relay max. 250 V AC/60 V DC max. 1 A AC (cos phi > 0.9), 1 A DC min. 50 mW, max. 250 VA, max. 40 W DC (with U < 40 V DC) 3 x output 0/4 … 20 mA, 20 … 0/4 mA 500 Ω Bluetooth 5.0 (downward compatible to Bluetooth 4.0 LE) Indicators Measured value indication ƲƲ Graphic-capable LC 89 x 56 mm, digital and quasianalogue display, with lighting display Adjustment elements Memory card Memory card type Ambient conditions Ambient temperature ƲƲ Instrument in general ƲƲ Display (readability) 4 x keys for menu adjustment microSDXC industrial Electrical protective measures Protection rating IP66/IP67 acc. to IEC 60529, Type 4X acc. to UL 50 Approvals The technical data in the respective safety instructions are valid for approved instruments (e.g. with Ex approval). In some cases, these data can differ from the data listed herein. All a

Open the catalog to page 1
Specification sheet VEGAMET 862 - 2

Specification sheet Adjustment Adjustment via the display and adjustment unit The adjustment of the VEGAMET 862 is carried out menu-driven via four front keys and a clearly arranged, graphic-capable display with background lighting. The VEGAMET 862 has an integrated display and adjustment unit. Alternatively, the parameter adjustment of the device can be done via Bluetooth and corresponding adjustment tools. Wireless adjustment via Bluetooth The Bluetooth version of the device enables wireless connection to smartphones/tablets (iOS/Android) or Windows PCs. Operation is via a free app from...

Open the catalog to page 2

All VEGA Grieshaber KG catalogs and technical brochures

  1. Image brochure

    68 Pages

  2. VEGAPULS 61

    2 Pages

  3. Offshore

    18 Pages

  4. FIBERTRAC 32

    2 Pages

  5. VEGAMIP R61

    9 Pages

  6. EL 3

    22 Pages