Ultrasonic level measurement In non-contact ultrasonic level measurement, the sensor emits ultrasonic pulses in the direction of the medium, which then reflects them back. The elapsed time from emission to reception of the signals is proportional to the level in the tank. Ultrasonic sensors are ideal for simple standard applications, both for liquids and bulk solids. Non-contact level measurement for a wide range of media Suitable for bulk solids and liquids Adjustment without medium or filling
Open the catalog to page 1Liquids and bulk solids in small vessels Liquids and bulk solids in small vessels Measuring range Liquids: 0.25 … 5 m Bulk solids: 0.25 … 2 m Liquids: 0.4 … 8 m Bulk solids: 0.4 … 3.5 m Process fitting Process temperature Process pressure Signal output 4 … 20 mA/HART, Profibus PA, Foundation Fieldbus 4 … 20 mA/HART, Profibus PA, Foundation Fieldbus PLICSCOM, PACTware/DTM, VEGADIS 81, VEGADIS 82 PLICSCOM, PACTware/DTM, VEGADIS 81, VEGADIS 82 ATEX, UKEX, IECEx, FM, CSA, EAC (GOST), UKR Sepro, Ship, SIL2 ATEX, UKEX, IECEx, FM, CSA, EAC (GOST), UKR Sepro, Ship, SIL2 Maintenance-free operation through...