Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR (Signal conditioning)
28Pages

{{requestButtons}}

Catalog excerpts

Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 1

Signal conditioning instruments

Open the catalog to page 1
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 2

Signal conditioning instruments For power supply of sensors and further processing of measured values Functional principle With a continuous level measurement, e.g. the level in a vessel is detected by a sensor and transferred to the VEGAMET signal conditioning instrument for further processing. By an adjustment in VEGAMET, the measured value can be adapted to the individual conditions. The requested parameter is shown in the display and outputted via the integrated current outputs. Hence the measuring signal can be transmitted to an external indication or superior control. Two or three...

Open the catalog to page 2
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 3

Overview Input Hysteresis Output Operating voltage 1 x 0/4 … 20 mA current output 2 x relay outputs 1 x fail safe relay 1 x 0/4 … 20 mA current output 6 x relay outputs or 5 x relay outputs and 1 x fail safe relay 1 x Ethernet (optional) 1 x RS232 (optional) 3 x 0/4 … 20 mA current output 3 x relay outputs 1 x fail safe relay 1 x Ethernet (optional) 1 x RS232 (optional) 2 x HART sensor input 3 x 0/4 … 20 mA current output 3 x relay outputs 1 x fail safe relay 1 x Ethernet (optional) 1 x RS232 (optional) 15 x HART sensor input 1 x fail safe relay 1 x Ethernet (optional) 1 x RS232 (optional)...

Open the catalog to page 3
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 4

Overview Instrument type Operating voltage 1 x sensor input NAMUR (IEC 60947-5-6) 1 x relay output (SPDT) 2 x sensor input NAMUR (IEC 60947-5-6) 2 x relay output (SPDT) 1 x sensor input two-wire 8/16 mA 1 x relay output (SPDT) Single channel signal conditioning instrument acc. to NAMUR VEGATOR 112 Double channel signal conditioning instrument acc. to NAMUR VEGATOR 121 Single channel signal conditioning instrument for level detection VEGATOR 122 Double channel signal conditioning instrument for level detection Optionally 1 fail safe relay output (SPDT) Optionally 1 fail safe relay output...

Open the catalog to page 4
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 5

VEGAMET 381 Signal conditioning and display instrument for level sensors Application area The VEGAMET 381 signal conditioning instrument powers the connected 4 … 20 mA/HART sensor, processes and displays the measured values. The VEGAMET 381 is ideal for simple control tasks in all industries. Comprehensive adjustment functions enable individual adaptations to the respective application. Your benefit Transmitter power supply via the 4 ... 20 mA sensor input Versatile use through two relay outputs to control pumps and stirrers, etc. Easily readable LC display for digital and quasianalogue...

Open the catalog to page 5
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 6

VEGAMET 391 Signal conditioning and display instrument for level sensors Application area The VEGAMET 391 signal conditioning instrument powers any 4 … 20 mA/HART sensor, processes and displays the measured values. The VEGAMET 391 is perfectly suitable for simple control tasks in level, gauge and process pressure measurements as well as for inventory management (VMI) and remote enquiry. Comprehensive adjustment functions allow individual adaptations to the respective application. In the water/sewage water industry, the instrument impresses with special functions such as pump switching-over,...

Open the catalog to page 6
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 7

VEGAMET 624 Signal conditioning and display instrument for level sensors Application area The VEGAMET 624 signal conditioning instrument powers the connected 4 … 20 mA/HART sensor, processes and displays the measured values. The VEGAMET 624 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application. Your benefit Steady utilization of the pumps through...

Open the catalog to page 7
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 8

VEGAMET 625 Signal conditioning and display instrument for level sensors Application area The VEGAMET 625 signal conditioning instrument powers the connected 4 … 20 mAA/HART sensor, processes and displays the measured values received through HART Multidrop. The VEGAMET 625 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application. Your benefit Versatile use...

Open the catalog to page 8
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 9

VEGASCAN 693 Signal conditioning instrument for up to 15 HART sensors Application area The VEGASCAN 693 is a signal conditioning and display instrument for up to 15 continuously measuring 4 ... 20 mA/HART sensors. Hence measurement results from level, gauge and process pressure measurements can be easily made available to control systems, visualizations and the remote data transmission. Interfaces and functions for the connection to networks and the remote data transmission are integrated. It is particularly suitable for applications in the local and global inventory management. Your...

Open the catalog to page 9
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 10

VEGATOR 620 Signal conditioning instrument for level detection Application area The VEGATOR 620 is a signal conditioning instrument for level detection for continuously measuring 4 ... 20 mA sensors. The instrument processes the measured value of a sensor and delivers a switching signal according to the adjusted switching threshold. Hence simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection as well as gauge monitorings. Your benefit Simple adjustment of the switching point via a potentiometer Clearly visible indication of...

Open the catalog to page 10
Product catalogue: Signal conditioning instruments VEGAMET, VEGASEL, VEGATOR  (Signal conditioning) - 11

VEGATOR 621 Signal conditioning instrument for level detection Application area The VEGATOR 621 is a signal conditioning instrument for level detection for continuously measuring 4 ... 20 mA sensors. The instrument processes the measured values of a sensor and delivers a switching signal according to the adjusted switching threshold. Hence simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection as well as gauge monitorings. Your benefit Simple adjustment of the switching point via a potentiometer Integrated fault monitoring...