Sensors gather measured values in a vessel and forward them to the controller. By adjusting the settings of the controller, the measured values can be adapted to the specific control requirements of the application. The values appear in the display and can be output through the integrated current outputs that are used to control external displays or higher-level control devices. Versatile application thanks to scalable outputs Simple integration into higher-level systems Easy installation with carrier rails
Open the catalog to page 1Measured value indication, limit value monitoring, pump control, flow measurement in open channels Measured value indication, limit value monitoring, pump control, flow measurement in open channels, data logger 1/2x 4 … 20 mA/HART sensor input 2/4x digital input 1/2x 0/4 … 20 mA current output 3x operating relay 1x fail safe relay (instead of an operating relay) 1/3x 0/4 … 20 mA current output 4/6x operating relay 1x fail safe relay (instead of an operating relay) Operating voltage Wall/pipe mounting in the field Wall/pipe mounting in the field LCD matrix display, black and white backlight with...
Open the catalog to page 2Measured value indication, limit value monitoring, pump control, flow measurement in open channels Measured value indication and simple control functions, remote data retrieval, data transmission optionally via Ethernet 1x 4 … 20 mA/HART sensor input 1/2x 0/4 … 20 mA current output 3x operating relay 1x fail safe relay (instead of operating relay) 1x 0/4 … 20 mA current output 6x operating relay 1x fail safe relay (instead of operating relay) 1x Ethernet (optional) 1x RS232 (optional) Operating voltage Panel mounting Front panel or wall mounting Carrier rail 35 x 7.5 mm acc. to EN 50022 LCD matrix...
Open the catalog to page 3Measured value visualisation, limit value monitoring, pump control, flow measurement in open channels Measured value indication, simple control functions as well as remote enquiry of measured values for one 4 ... 20 mA/HART sensor, data transmission optionally via Ethernet Measured value indication, simple control functions as well as remote enquiry of measured values for two HART sensors, data transmission optionally via Ethernet Measured value indication and remote enquiry of measured values for up to 15 HART sensors, data transmission optionally via Ethernet 1x 4 … 20 mA/HART sensor input...
Open the catalog to page 4Transmission of NAMUR signals for level signalling Transmission of 8/16 mA signals for level signalling 1/2x NAMUR sensor input 1/2x two-wire 8/16 mA sensor input VEGATOR 111: 1x operating relay (SPDT), optional 1x fail safe relay (SPDT) VEGATOR 121: 1x operating relay (SPDT), optional 1x fail safe or operating relay (SPDT) VEGATOR 112: 2x operating relay (SPDT) VEGATOR 122: 2x operating relay (SPDT) Operating voltage 1x LED voltage supply 1x LED switching signal per channel 1x LED false signal per channel 1x LED voltage supply 1x LED switching signal per channel 1x LED false signal per channel...
Open the catalog to page 5Operating voltage Mounting
Open the catalog to page 616 Pages
72 Pages
6 Pages
2 Pages
8 Pages
9 Pages
22 Pages