Catalog excerpts
Mounting accessory Page 320 plies® housing overview Page 328 Material names Page 330
Open the catalog to page 1VEGAPASS 81 Bypass for continuous level measurement of liquids Application area The combination of VEGAPASS 81 with VEGAFLEX enables a continuous level measurement outside the vessel. The bypass consists of a standpipe which is mounted as communicating vessel laterally to the vessel via two process fittings. This kind of mounting ensures that the level in the standpipe and the vessel are the same. Your benefit Maintenance-free system without mechanically moving parts Simple, robust and proven mechanical construction Technical data Version: Process temperature: according to ASME or PED -196...
Open the catalog to page 2Center - Center (M) Ø60.3x2 mm /316L (300-4000 mm)per 100 mm Ø60.3x2.77 mm (2"Schedule 10)/316L (300-4000 mm) per 100 mm Ø88.9x2 mm /316L (300-4000 mm)per 100 mm Ø88.9x3.05 mm (3"Schedule 10)/316L (300-4000 mm) per 100 mm Distance vessel connections 90° displaced (L) Ø60.3x2 mm /316L (300-4000 mm)per 100 mm Ø60.3x2.77 mm (2"Schedule 10)/316L (300-4000 mm) per 100 mm Ø88.9x2 mm /316L (300-4000 mm)per 100 mm Ø88.9x3.05 mm (3"Schedule 10)/316L (300-4000 mm) per 100 mm
Open the catalog to page 3Threaded flanges stainless steel 316L Threaded flanges plastic PPH Accessory – Threaded flange
Open the catalog to page 4Welded socket Clamp Welded socket bolting Accessory – Welded socket
Open the catalog to page 5Welded socket cone connection Welded socket hygienic fitting Accessory – Welded socket
Open the catalog to page 6Welded sleeve Accessory – Welded sleeve – Counter nut
Open the catalog to page 7Protective cover Protective cover for plics® devices The protective cover protects the sensor housing and the cable entry against extreme weather conditions and contamination. The weather resistant plastic PBT in light-grey is used as material. Wall bracket with slide adapter For wall mounting of VEGA instruments The wall bracket of StSt 1.4301/304 is suitable for wall mounting of VEGA instruments and offers the possibility to vary the wall distance depending on the application. The required mounting material is attached. You can find drawings and tables under www.vega.com/downloads....
Open the catalog to page 8Wall bracket with rotary T-adapter For wall mounting of VEGA instruments The wall bracket of StSt 1.4301/304 is suitable for wall mounting of VEGA instruments and offers in addition the possibility to vary the position of the sensor in three directions. The required mounting material is attached. Mounting bracket For wall mounting of VEGA instruments The robust and high resistance angle bracket of StSt 1.4301/304 is suitable for wall mounting of VEGA instruments. The required mounting material is attached. Accessory – Wall bracket – Mounting bracket You can find drawings and tables under...
Open the catalog to page 9Mounting strap For mounting of VEGA instruments The mounting strap of 316L offers the advantage of a simple mounting and the specific orientation of radar and ultrasonic sensors. The required mounting material is attached. Mounting bracket with 45° reflector For mounting of radar sensors VEGAPULS 61 and VEGAPULS WL 61 Reflector for lateral deflection of the radar signals via a surface which is declined by 45° with integrated fastening and complete mounting set. Particularly suitable for mounting in overflow basins and closed channels. Through the deflection of the signals via the reflector,...
Open the catalog to page 10Version Single chamber Double chamber Application area Industrial environment Industrial environment Version Single chamber Double chamber Application area Industrial environment with Industrial environment with increased mechanical stress increased mechanical stress Application area Single chamber electropolis- Aggressive environment, foodstuffs, pharmaceutical Single chamber precision Aggressive environment, strong mechanical stress Double chamber precision Aggressive environment, strong mechanical stress Accessory - plies® housing overview
Open the catalog to page 12The two dimensions of the housing height refer to the use with and without display/ adjustment module PLICSCOM. 1 Single chamber housing 2 Double chamber housing 1 Single chamber housing 2 Double chamber housing The two dimensions of the housing height refer to the use with and without display/ adjustment module PLICSCOM. Stainless steel housing Accessory – plics® housing overview 1 Single chamber housing electropolished 2 Single chamber housing precision casting 3 Double chamber housing precision casting The two dimensions of the housing height refer to the use with and without display/...
Open the catalog to page 13Material names ECTFE = Ethylene-Chlortrifluorethylene Copolymer (Halar) FEP = Tetrafluorethylene-Hexafluorpropylene (also PFEP) PFA = Perfluor-Alkoxyalkan = Tetrafluorethylene - Perfluoralkylvinylether - Copolymer PPH = Polypropylene high density Accessory - Material names
Open the catalog to page 14All VEGA Grieshaber KG catalogs and technical brochures
-
Image brochure
68 Pages
-
VEGAPULS 61
2 Pages
-
Level l Radar
6 Pages
-
Environnement et le recyclage
14 Pages
-
Production d'énergie
18 Pages
-
Offshore
18 Pages
-
Approvisionnement en eau potable
18 Pages
-
FIBERTRAC 32
2 Pages
-
VEGAPULS WL S 61
2 Pages
-
Wireless communication
8 Pages
-
VEGAMIP R61
9 Pages
-
EL 3
22 Pages
-
Microwave barrier VEGAMIP
12 Pages