Catalog excerpts

Insertable gate valve Space saving due to direct mounting between DIN flanges / sealing surfaces Body material aluminum Manual actuator DN 50: toggle lever DN 63 - 100: push rod Ordering numbers inch 08234-FA06 double acting with position indicator with solenoid Pneumatic actuator without position indicator, without solenoid: 08 . . . -FA14 with position indicator, without solenoid: 08 . . . -FA24 Actuator: - Solenoid for impulse actuation: actual valve position is maintained at power failure - Solenoid separate, for external mounting - Solenoid for 12, 48 V DC 24, 48, 100, 115, 200, 230 V 50 Hz 24, 100, 115, 200, 230 V 60 Hz Valve: valve seat side - Port with seal made of VITON (diagram 1) for DN 63 - 100 for roughing (by-pass), venting or for gauges (recommended port: ISO-KF16 for DN 63, ISO-KF25 for DN 80 and 100) Ordering information for options: Ordering No. of valve-X (e. g. 08140-FA44-X, X = port ISO-KF25 at position A) Consisting of seals for flanges, gate and lower part of body Ordering No.: see operating manual or price list
Open the catalog to page 1
Sealing materials Gate: Bonnet: VITON Feedthrough VITON / shaft feedthrough 1 vacuum tubing 2 body 3 valve gate 4 counter plate 5 ball pairs 6 flange seal 7 gate seal a valve seat side Flanges with DIN centering insert Technical data Leak rate: body, valve seat Pressure range Differential pressure on the gate - DN 50 / 63 - 100 Differential pressure at opening Cycles until first service - DN 50 / 63 - 100 Temperature 1) - Valve body DN 50 / 63 - 100 - Manual actuator - Pneumatic actuator - Position indicator - Solenoid Continued next page VATLOCK configuration (see glossary) Material -...
Open the catalog to page 2
Insertable gate valve dimensions of flange O-ring valve seat side required for dismantling Technical data closing or opening time compressed air pressure min. - max. overpressure molecular flow conductance
Open the catalog to page 3
dimensions of flange O-ring valve seat side required for dismantling emergency operation compressed air connection electrical connection position indicator mechanical position indication
Open the catalog to page 4All VAT Vakuumventile AG catalogs and technical brochures
-
97.0 SERIES- MODULES
3 Pages
-
271 series
2 Pages
-
752 series
4 Pages
-
590 series
4 Pages
-
230 series
2 Pages
-
191 series
8 Pages
-
172 series
8 Pages
-
HV angle valve
4 Pages
-
Large door L-VAT
2 Pages
-
Rectangular valve FlapVAT
2 Pages
-
Atmospheric door L-VAT
4 Pages
-
All-metal gate valve
8 Pages
-
Large gate valves (V)
6 Pages
-
HV gate valve
8 Pages
-
HV gate valve with Bellows
8 Pages
-
053
4 Pages
-
650
9 Pages
-
190
6 Pages
-
264
10 Pages
-
Large Transfer valve
2 Pages
-
540
2 Pages
-
284
4 Pages
-
243
2 Pages
-
220
2 Pages
-
Transfer valve
6 Pages
-
022
6 Pages
-
640
10 Pages
-
612
6 Pages
-
091
6 Pages
-
010
6 Pages
-
VAT Catalogue 2012
234 Pages