Product catalog summary
Charging Procedures at Different Temperatures
The document specifies the maximum charging currents for CoinPower batteries across various temperature ranges. For temperatures between 0°C and 5°C, a maximum charging current of 0.1C is recommended, increasing to 0.2C for 5°C to 10°C, and 0.4C for 10°C to 15°C. The charging method must always be Constant-Current Constant-Voltage (CCCV).
Charging Procedures Comparisons
A table compares charging times and capacities at different temperatures and charging rates. For instance, at 0°C to 5°C, the average charging time is 600 minutes at 0.1C, while at 15°C to 45°C, it is 135 minutes at 1C.
CoinPower Versions and Charging
The CoinPower C-Version supports standard, fast, and rapid charging procedures with specific C-Rates and temperature ranges. The F-Version supports standard charging with a maximum C-Rate of 0.5C.
Discharging Procedures
CoinPower batteries can handle high discharge currents. The A-Version supports continuous discharge at 2C and pulse mode at 3C. The C-Version can handle up to 5C, and the F-Version up to 2C. Discharge should occur between -20°C and 60°C.
Over-Discharging Prevention
To prevent over-discharging, cells should be periodically charged to maintain a voltage between 3.0 V and 3.8 V. Over-discharging can impair battery function.
Charging IC Recommendations
Recommended charging ICs include models from Texas Instruments and Linear Technology, which support the CCCV charging method.
Reliability and Life Expectancy
VARTA CoinPower batteries offer a cycle life of over 500 cycles with more than 80% capacity retention. They perform well even at high temperatures and discharge currents.
Storage Recommendations
Batteries are delivered with a 30% state-of-charge for optimal storage. They should be stored at 30% to 50% SoC at room temperature to minimize self-discharge.
Safety Standards and Tests
CoinPower batteries comply with UL 1642, IEC 62133, and UN IATA 38.3 safety standards. Various tests ensure safety, including short circuit, crush, and overcharge tests.
Protection Circuit Module (PCM)
A PCM is essential for protecting against over-charge, over-discharge, and short circuits. Recommended PCMs include models from SG Micro and Ricoh.
Handling Precautions
The document provides guidelines on handling, charging, discharging, and storing CoinPower batteries to ensure safety and performance.
Handling Precautions and Prohibitions for VARTA CoinPower Batteries
General Guidelines: This document outlines the handling precautions, prohibitions, and general supply notices for VARTA CoinPower batteries. It is crucial for all handlers to be aware of these guidelines to ensure safety and optimal performance. Customers should contact VARTA for applications or conditions not covered in this document, as additional testing may be required.
Charging Instructions: Charging current must not exceed the maximum specified in the Data Sheet. Charging above 4.3 V is prohibited, and the temperature must be within the specified range. Reverse charging is strictly forbidden as it can damage the cell and compromise safety.
Discharging Instructions: Discharge current should not exceed the maximum specified. Over-discharging can lead to performance loss, and preventive measures should be in place to avoid discharging below the cutoff voltage.
Protection Circuit Module (PCM): The PCM should prevent overcharging, over-discharging, and overcurrent to maintain safety. It should minimize dissipation current to preserve battery life.
Application and Storage: VARTA CoinPower batteries are not user-replaceable and should only be serviced by trained technicians. Storage should be within the specified temperature range, and the state of charge should be maintained at 30% of nominal capacity.
Assembly and Safety: Direct soldering or welding to the cell is prohibited. Adequate insulation and design to prevent short-circuits are necessary. Damaged cells should not be used, and any abnormal features should be reported.
Warnings and Disposal: Cells should not be disassembled, short-circuited, or exposed to fire or liquids. Proper disposal according to local laws is required, and batteries should be kept out of reach of children to prevent ingestion.
Handling Precautions and Prohibitions
- Seek medical assistance promptly if a cell or battery is ingested. Avoid throwing batteries into water or fire, deep discharging, and short-circuiting. Follow recommended charging times and currents. Do not open or disassemble batteries.
Supply to Private End Users
- Products supplied to private end users should adhere to UL product and instruction manual requirements. Mark products with a symbol directing users to the instruction manual, which should include warnings and hazard descriptions.
Marking Requirements
- Comprehensive instructions and markings should be prepared for end users, including safety instructions and prohibitions as per UL 1642 and other specifications. Markings should include manufacturer details and warnings about risks such as fire, explosion, and burns.
Battery Assembly
- VARTA Microbattery offers customized solutions for battery assembly, including single and multicellular configurations. Soldering guidelines emphasize avoiding direct contact with the cell body and not using reflow soldering due to safety risks.
Application Checklist
- To find the best energy solution, VARTA Microbattery requires specific information from customers. Contact details are provided for further assistance.
Glossary
- Definitions of terms such as OEM, battery, cell, secondary battery, primary battery, separator, cathode, anode, and various technical specifications related to battery performance and safety are provided.
Contact Information
- Contact details for VARTA Microbattery's headquarters and regional offices in Asia Pacific, Japan, China, Taiwan, Hong Kong, and the USA are listed.
See more

Catalog excerpts

Coin Power-1

Technical Handbook Rechargeable Li-Ion Button Cells

 Open the catalog to page 1
Coin Power-2

Content 1. GENERAL INFORMATION ______________________________________ 1.1 Definitions __________________________________________________ 1.2 Features ____________________________________________________ 1.3 Applications _________________________________________________ 1.4 General design and application c riteria __________________________ 1.5 Construction and electromechanical processes of CoinPower Batteries ______________________________ 2. MISCELLANEOUS ____________________________________________ 10 2.1 Specification table VARTA CoinPower Batteries ___________________ 11 2.2 Data-Matrix...

 Open the catalog to page 2
Coin Power-3

1. General Information 1.1 Definitions 1.2 Features 1.3 Applications 1.4 General design and application criteria 1.5 Construction and electromechanical processes of CoinPower Batteries

 Open the catalog to page 3
Coin Power-4

COINPOWER | GENERAL INFORMATION General Information VARTA Microbattery is a leading manufacturer of batteries and provides professional support worldwide to customers to help them to design VARTA batteries into their applications. Quality, reliability, high performance and customer satisfaction are the main reasons for our leading position in the market. VARTA Microbattery provides solutions to major OEM companies for high-tech applications such as Bluetooth headsets, activity trackers, heat cost allocator devices, back-up for memory and the real-time clock in PCs / notebooks as well as alarm...

 Open the catalog to page 4
Coin Power-5

COINPOWER | GENERAL INFORMATION 1.1 Definitions Unless otherwise stated, specified values are valid for operation at room temperature 20 ºC ± 3 ºC. Specific Data The gravimetric energy density of the Li-Ion Coin Power series depends on battery size, and ireaches up to 190 Wh/kg. Volumetric energy density ranges up to 500 Wh/l. Voltage Definitions Open Circuit Voltage (OCV): Equilibrium potential 3.0 V to 4.3 V on average, dependent on temperature, storage duration and state of charge. Nominal Voltage of Li-Ion cells is 3.7 V End of Discharge Voltage (EOD): The voltage at the end of discharging...

 Open the catalog to page 5
Coin Power-6

COINPOWER | GENERAL INFORMATION 1.2 Features VARTA CoinPower batteries are the first choice for a number of modern high-tech portable products. They provide a long lasting, reliable main power source which is lightweight and occupies a minimum of space in the host device. VARTA CoinPower batteries meet the most important design requirements of these products: Reliable high-power output, design flexibility with a minimum of space requirement and a round form factor. • High energy density • Wound electrode design • Built-in safety device with chemical safety components • Fully automated production...

 Open the catalog to page 6
Coin Power-7

COINPOWER | GENERAL INFORMATION 1.3 Applications VARTA CoinPower batteries are especially suitable for modern electronic applications such as Bluetooth Mono / Stereo Headsets, Sensors for Fitness / Sport / Healthcare, Smart Watches, Wearable Technology, Smart Car Keys and many more. These cells are the ultimate power source for your electronic devices and make your products smaller, lighter and more attractive. VARTA CoinPower provides outstanding performance and reliability, excellent quality along with very safe operation. IOT Smart Home

 Open the catalog to page 7
Coin Power-8

COINPOWER | GENERAL INFORMATION 1.4 G eneral design and application criteria Choose the most suitable battery from our range of VARTA CoinPower cells for the needs of your application and the conditions in which it is expected to operate. The most important criteria for the selection of battery type are these: • • • • • • • Required minimum operating time Max. and average current drain Min. and max. operating voltage Operating temperature range Mechanical properties Available space Environmental conditions You can choose a cell from the VARTA CoinPower range to operate within the following limits:...

 Open the catalog to page 8
Coin Power-9

COINPOWER | GENERAL INFORMATION 1.5 C onstruction and electromechanical processes of CoinPower Batteries The housing of the CoinPower cells consists of two stainless steel parts. This gives the cell very high mechanical stability during assembly in the end-product as well as during the product’s use by the customer. Inside the cell the anode, cathode and separator are wound to a coil. The connection of the electrodes to the housing is made by welding from the outside to the lid and cup. The innovative design of the housing, combined with its foil gasket, provides for the most efficient use of...

 Open the catalog to page 9
Coin Power-10

2. Miscellaneous 2.1 Specification table VARTA CoinPower Batteries 2.2 Data-Matrix Code

 Open the catalog to page 10
Coin Power-11

2.1 S pecification table VARTA CoinPower Batteries The CoinPower is available in three different chemistries, different diameters and 3 different heights. Version Technology Nominal Voltage Max. charging Current Cell diameters in the range of 7.8 mm up to 21 mm Further designs on request Model Number The model numbers are two uppercase letters and a figure consisting of four digits. The version number consists of one letter and one figure as shown in the example. Model Number Battery Type (CP – CoinPower) Cell Height (here: 5.4 mm) Cell Diameter (here: 16 mm)

 Open the catalog to page 11
Coin Power-12

2.2 Data Matrix Code In order to make every single cell fully traceable, two data matrix codes are printed on lid and cup of each one. This codes provide information about the production date, the version and the winder or assembly line. Please note that the codes are printed on every individual cell produced in Germany. The battery code is different, and is indicated on the battery drawing. Data Matrix Code cell diameter ≥ 10 mm Data Matrix Code Unique cell identification code Data Matrix Code Unique cell identification code Day of the year

 Open the catalog to page 12
Coin Power-13

Data Matrix Code cell diameter < 10 mm Data Matrix Code Unique cell identification code Day of the year 0124010740 Date Code Version number VARTA Day of the year

 Open the catalog to page 13
Coin Power-14

Charging Specific Charging A-Version Specific Charging C-Version Specific Charging F-Version 3.2 Discharging Specific Discharging A-Version Specific Discharging C-Version Specific Discharging F-Version 3.3 Charging IC

 Open the catalog to page 14