Type Designation and Specifications
The CoinPower CP 1254 A3 is a lithium-ion battery with a cell code of ICR1254 and a system composition of graphite-layered metal oxide (LiNixMnyCozO2). It has a nominal voltage of 3.7V and a nominal capacity of 60mAh, with a typical capacity of 63mAh.

Dimensions and Weight
The battery has a diameter of 12.1mm, a height of 5.4mm, and weighs approximately 1.6g.

Charging Method and Parameters
The battery uses a constant current plus constant voltage charging method with a charge voltage of 4.20V ± 0.05V. Initial charge currents are 30mA for standard charge, 60mA for fast charge, and 120mA for rapid charge. Charging cut-off can be by time (5 hours for standard, 3 hours for fast/rapid) or by minimum current (1.2mA).

Discharge and Operating Conditions
The discharge cut-off voltage is 3.0V. The maximum pulse discharge current is 180mA for 2 seconds, and the maximum continuous discharge current is 120mA. Operating temperatures range from 0 to 45°C for charging and -20 to 60°C for discharging.

Storage and Cycle Life
The battery retains over 90% capacity after 1 year at -20 to 20°C, over 90% after 3 months at -20 to 45°C, and over 85% after 1 month at -20 to 60°C. It has an initial impedance of less than 0.5Ω at 1kHz and a cycle life of over 500 cycles at 0.5C/0.5C, maintaining more than 80% of initial capacity.

Safety and Compliance
The battery has passed UN 38.3 and IEC 61233 safety tests. It also passed internal overcharge tests at 12V, 3C, 12h, and 5V, 1A, 12h.

Recommendations and Patents
The battery must be used with external safety electronics (PCM) and is intended for specific purposes. For medical applications, contact VARTA Microbattery. The product is protected by multiple patents, including US and EP patents.
See more

Catalog excerpts

63125-1

Data Sheet CoinPower® CP 1254 A3Data Sheet - CP 1254 A3 (CoinPower®)1 Type Designation Type Number Cell Code System Nominal Voltage [V] Typical Capacity C [mAh] Nominal Capacity C [mAh] CP 1254 A3 63125 ICR1254 Graphite - layered metal oxide (LiNixMnyCOzO2) MH13654 3.7 (average) 63 (at 0.2C from 4.2 V to 3.0 V at 20 °C) 60 (at 0.2C from 4.2 V to 3.0 V at 20 °C) Charging Cut-Off (a) or (b) a) by time [h] b) by min current [mA] Discharge Cut-Off Voltage [V] Max. Pulse Discharge Current [mA] Max. Continuous Discharge Current [mA] Operating Temperature [°C] Storage Temperature Capacity Recovery Rate4 [%] Impedance Initial [Q] Cycle Life 0.5C/0.5C, 20 °C5 [Cycles] Standard Charge: 5 Fast/Rapid Charge: 3 1.2 3.0 180 @2s 120 Charge: 0 to 45 UN 38.3 passed relevant tests acc. IEC 61233 passed passed passed 1 Recommendations regarding Charging/Discharging and Safety (cf. Handling Precautions/Advanced Product Information) have to be accepted. Cell must not be used without external safety electronics (PCM - Protection Circuit Module)! The CoinPower cell may exclusively be used for the intended purpose. For medical applications please contact VARTA Microbattery. This product is protected by at least one of the following patents: US 6265100 B1,US 6066184 A,US 9178251 B2,US 9231281 B2,US 8586232 B2,US 9153835 B2,CN 102318122 B,CN 102804473 B,EP 2628203 B1,EP 2443691 B1,EP 2415101 B1,EP 2394324 B1,JP 5767115 B2,DE 19647593 B4. 2 “CoinPower A3-Version Charging Document” must be observed. 3 “CoinPower A3-Version Charging Document” must be observed. Max. charging voltage: 4.00V ± 0.05V; min. charging temperature: 15°C. 4 After storage at initial cell voltage of 3.6 to 3.7 V / cell 5 typical values Subject to change without prior notice!