Catalog excerpts
The P series is an all-round system for the disinfection The P-series stands for efficiency and ease. The systems of processed water, water re-use and recycling, was- can treat up to 360m³ water per hour at a dose of 300 te water, and cooling water: in general liquids with a J/m2, with a very low energy use and very imited l t ransmittance anging from 60% to 80%. r maintenance costs. Characteristics • Reliable and effective disinfection • Low maintenance • Easy to use • Energy efficient • Low-pressure lamps with a long lifespan and high UV-
Open the catalog to page 1Specifications Type UV Chamber Material In-/Outlet Connections Pressure drop Mounting orientation Diameter - A (mm) Vertical / Horizontal Vertical / Horizontal Vertical / Horizontal Vertical / Horizontal Required working space - E (mm) UV-C lamp Lamptype (low pressure) Preferred water temp. (°C) Total UV-C output (Watt) Lamp lifespan (hours) Number of lamps Control unit Material Dimensions (lxbxh) Control features Lamp status, lamp hours, system running time, volt free alarm contacts Sensors (Optional) UV-C sensor (UVS) and Temperatuur Safety Sensor (TSS) Operating Voltage Electrical...
Open the catalog to page 2Specifications Type UV Chamber Material In-/Outlet Connections Pressure drop Mounting orientation Diameter - A (mm) Vertical / Horizontal Vertical / Horizontal Required working space - E (mm) UV-C lamp Lamptype (low pressure) Preferred water temp. (°C) Total UV-C output (Watt) Lamp lifespan (hours) Number of lamps Control unit Material Dimensions (lxbxh) Weight (KG) Control features Sensors (Optional) Lamp status, lamp hours, system running time, volt free alarm contacts UV Sensor (UVS), Temperature Safety Sensor (TSS). Temperature Safety Dumpvalue (TSD) Operating Voltage Electrical...
Open the catalog to page 3Specifications Type UV Chamber Material In-/Outlet Connections Pressure drop Mounting orientation Diameter - A (mm) Required working space - E (mm) UV-C lamp Lamptype (low pressure) Preferred water temp. (°C) Total UV-C output (Watt) Lamp lifespan (hours) Number of lamps Besturingskast Material Dimensions (lxbxh) Weight (KG) Control features UV-C sensor (UVS) en Temperatuur Safety Sensor (TSS) Temperature Safety Dumpvalue (TSD) Operating Voltage Protection rating Preferred ambient temp. (°C) Total Power Consumption (W) Lamp status, lamp hours, system running time, volt free alarm contacts...
Open the catalog to page 4Capacities in m3/h at a dose of 300 J/m2 Unit Van Remmen UV Technology is not responsible for any printing errors in this document and reserves the right to amend equipment or specifications without prior notice.
Open the catalog to page 5All Van Remmen UV Techniek B.V. catalogs and technical brochures
-