[ Protection & Control ] motor protection and control from VAMP VAMP 40, VAMP 52, VAMP 230, VAMP 255, VAMP 257 and VAMP 265M CUSTOMER BENEFITS • Complete protection for motors Comprehensive selection of protection functions for asynchronous circuit breaker controlled motors. • Temperature measurement nterface to external VIO 12A RTD input module for twelve Pt, Ni or Cu temperature sensors. The external module enables the sensor connection point to be close to the motor, minimising sensor cable ength. Measurements are transferred to the relay via RS485 or optical interface for the required protection stages, logic or • Ultra-fast arc flash protection VAMP motor protection has an unique integrated arc fault protection functionality for enhanced safety of the motor termination box, switchgear as well as people and other property. This optional arc flash protection module enables the protection relay to become a part of the substation level arc flash protection • Comprehensive measurements Motor control, measurement of electrical quantities, disturbance and event capturing as well as extensive range of industrial protocol interfaces are standard features in VAMP motor protection • Extensive communication Large number of supported communication protocols including Modbus RTU, Profibus DP, TCP/IP, SPA-bus slave, DNP 3.0 VAMP Motor protection relays are used for the selective protection of motor control centres, motor cabling and termination, asynchronous motor and the primary load of the machine Typical applications are low and medium voltage ndustrial processes, power plants, marine and offshore installations. Besides a comprehensive range of standard protection functions the VAMP relays also offers temperature measurement with external RTD input module A unique feature of VAMP relays is the arc flash fault protection system integrated into the relays. The extremely fast arc fault protection option adds a new dimension to the total safety of the installation and the reliability of the motor protection system Further, the VAMP relays incorporate power quality assessment based on fast Fourier transform. Following a network or motor fault, the relays support fault analysis by providing event sequence recordings, fault value registration and disturbance recorder capability. Customer specific configuration is obtained by freely configurable mimic display and logic programming using the easy-to-use VAMPSET software. VAMP products also have a multilingual human machine interface VAMP Protection offers a solution to maximise safety in all applications.
Open the catalog to page 1Quick selection table User-friendliness has always been a feature of VAMP products, and the motor protection is no exception. A great deal of effort has gone into the design of the operational aspects of the new The rapid setting and download/upload is achieved with the unique VAMPSET setting software which dramatically improves usability Unicode support allows the menu text and settings to be translated into various international languages including for example Russian and Chinese. The informative human machine nterface shows all of the required information to the user with support of...
Open the catalog to page 2Protection & Control VAMP 40 / 52 / 230 / 255 / 257 / 265M Product highlights VAMP 40 • • • • • Unique digital multifunctionality at basic cost One type designation only; wide power supply range; 19-265 V ac/dc Small installation depth dimension 2 Digital Inputs (fixed) Connectivity to PTD input module VAMP 52 • • • • • • Digital multifunction relay for asynchronous motors Large display for mimic and measurements Control keys for operational mode changes Control keys for object control Optional mA output Two optional module slots for arc sensor, Input/Output extension or various...
Open the catalog to page 3VAMPSET setting and configuration tool VAMPSET is a user-friendly, free-of-charge relay management software for setting parameters and configuring VAMP relays.Via the VAMPSET software, relay parameters, configurations and recorded data can be exchanged between PC and VAMP relays. Supporting the COMTRADE format, VAMPSET also incorporates tools for analyzing relay events, waveforms and trends from data recorded by the relays, e.g. during a network fault situation Using a standard serial cable the PC running VAMPSET connects to the front or rear port of the VAMP relays. The VAMPSET software...
Open the catalog to page 4Functionality of VAMP motor protection relays Short circuit Three-phase non-d Three-phase non-d Three-phase non-d ^secondary side) onal overcurrent, low-set stage, definite or inverse time onal overcurrent, high-set stage, definite time onal overcurrent, low-set stage, definite or inverse time Other functions Three-phase non-directional overcurrent, high-set stage, definite time ^secondary side) onal or non dir. o/c, low-set stage, definite or inverse time Three-phase directional or non dir. o/c, high-set stage, definite time gh-set stage, definite or inverse time gh-set stage, definite...
Open the catalog to page 5Primary current Primary voltage Short-circuit fault reactance Voltage sags / swells Analog mA output, 1 channel Analog mA output, 4 channels Three-phase differential current Neutral current Current unbalance Average and maximum demand current One-/Three-phase and line voltages Zero sequence voltage Short-circuit fault reactance System frequency Active power Reactive power Apparent power Active Energy exported / imported Power factor Voltage sags / swells Any measured or calculated value, freely scalable Any measured or calculated value, freely scalable, Optional Condition monitoring SPA-bus...
Open the catalog to page 6Typical applications • External support to arc interface module • Large mimic • Extended DI/DO for breaker status indication • Three phase voltage inputs for directional overcurrent protection, power and energy • VAMP 257 for double busbar control • Combined motor and differential protection • Differential stage optimized for motors Redundant protection with VAMP 52 and VAMP 265M • Motor protection and back-up motor protection with differential element
Open the catalog to page 7All Vamp catalogs and technical brochures
-
vamp 265
2 Pages
-
VAMP 11V
16 Pages
-
VAMP 1 1 F
16 Pages
-
VAMP 50 series
20 Pages
-
VAMP 96 and VAMP 260
12 Pages
-
VAMP 57
16 Pages
-
VAMP 259
12 Pages
-
VAMP 230, VAMP 255 and VAMP 257
16 Pages
-
VAMP 125
1 Pages
-
VAMP 125 Unit for flexible
12 Pages
-
VAMP 120 & 121
8 Pages
-
VAMP 11V
16 Pages
-
VAMP 321
12 Pages
-
VAMP 59
12 Pages
-
VAMP 55
190 Pages
-
VAMP 120
8 Pages
-
VAMP 50
20 Pages
-
VAMP 230
16 Pages
-
VAMP 210
2 Pages
-
VAMP 135
8 Pages
Archived catalogs
-
VAMP 221_2013
16 Pages
-
VAMP 221_2011
16 Pages
-
VAMP 96
16 Pages
-
ARC Protection
20 Pages
-
Customer
28 Pages
-
Vamp Arc Protection Series
16 Pages
-
Vamp Feeder/Motor Manager
16 Pages
-
Selection table
1 Pages
-
Vamp Protection Relays
16 Pages