VAMP 230, VAMP 255 and VAMP 257
16Pages

{{requestButtons}}

Catalog excerpts

VAMP 230, VAMP 255 and VAMP 257 - 1

VAMP 230, VAMP 255 and VAMP 257 Feeder and Motor manager series The protection relays of the VAMP Series are used for the selective protection of overhead line feeders, cable feeders, motor feeders, capacitor banks, reactors and busbars in power system distribution substations, power plants, industrial power systems, marine and offshore installations. Besides a comprehensive range of standard protection functions the VAMP series also offers bay control, measurement, primary circuit monitoring and communication functionality. main characteristics • Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable feeders, motor feeders including large motors, capacitor banks and reactors. • Total control Extensive bay control functionality including local and remote control of six objects and status supervision of another two objects. • Comprehensive measurements Wide range of measurement functions including phase-to-earth, phase-to-phase voltages, currents, frequency, active, reactive and apparent power, active and reactive energy imported and exported, power factor, negative phase sequence current, etc. • ower quality assessment P Power quality assessment and analysis including super­ ision of v harmonics up to the 15th order, THD as well as voltage swells and sags. • Fault location Integrated fault location with distance indication for short circuits in distribution networks irrespective of power network earthing system and earth-faults in compensated networks. • ltra-fast Arc flash protection U Unique integrated arc fault protection functionality for enhanced safety of switchgear, substations, people and property. • Extensive communication Large number of supported communication protocols including IEC 60870-5-101, IEC 60870-5-103, Modbus TCP, Modbus RTU, Profibus DP, TCP/IP, SPA-bus slave, DNP3.0, DNP TCP, IEC 61850, Device Net or Ethernet /IP. • asy handling and management E Easy commissioning, configuration and operation of the relays supported by the straight-forward VAMPSET relay management software A unique feature of the VAMP relays is the arc fault protection system integrated into the relays. The extremely fast arc fault protection option adds a new dimension to the total safety of the installation and the reliability of the protection system. Further, VAMP relays incorporate power quality assessment based on fast Fourier transform and fault spot location based on fault reactance calculation. Customer specific configuration is obtained by freely configurable mimic display and logic programming by means of the easy-to-use VAMPSET software. After a network fault the relays support a subsequent fault analysis by providing event sequence recordings, fault value registration and disturbance recorder capability. Comprehensive functionality and communication makes VAMP an ideal choice through

Open the catalog to page 1
VAMP 230, VAMP 255 and VAMP 257 - 2

[Protection] VAMP 230, VAMP 255, VAMP 257 02 VAMP 230, 255 and 257 are all suitable for applications where reliable control and protection is needed. The features of the products vary in the number of digital inputs and outputs and in the number of analog measuring channels. KUtDiLbr J r SfciiS iJ C.-S MUtfattt.* : r Srkjr; ii. (aft Mintef rf Lb WffWTf if Vi mK*q£f *-r ti ! HTIfT! “rflitt:* iaa KiiTj KMswaar km i-HU»U*r KM !h ■. la.'i-aer ciaij; r*» i^asvrrv*^ crvr ;h Many functions in modern society rely heavily on electric energy and therefore the quality of the energy supply is...

Open the catalog to page 2
VAMP 230, VAMP 255 and VAMP 257 - 3

[Protection] VAMP 230, VAMP 255, VAMP 257 03 The feeder manager includes a sophisticated stand-alone fault location function. The algorithm used can accurately locate short-circuits in any type of distribution networks. The fault location is given as a reactance value, and the distance to the fault is also displayed on the local HMI, optionally as a mA signal and as a message over the communication system. The distance value can be exported, for example, as an event to a DMS (Distribution Management System). The system can then locate the fault. If a DMS is not available, the distance to...

Open the catalog to page 3
VAMP 230, VAMP 255 and VAMP 257 - 4

Protection VAMP 230, VAMP 255, VAMP 257 Communication VAMP is a communication expert with a wide experience in interfacing with different system integrators’ and SCADA suppliers’ RTUs, PLCs, gateways etc. using different protocols. Flexible adaptation of the communication protocols together with powerful and easy to use software tools are the key of successful integration. VAMP protection relays and the VAMPSET tool provide access to practically any power system information you may need. The VAMP feeder manager series feature three serial communication ports, two on the rear plate for...

Open the catalog to page 4
VAMP 230, VAMP 255 and VAMP 257 - 5

[Protection] VAMP 230, VAMP 255, VAMP 257 05 VAMPSET is a user-friendly, free-of-charge relay management software for setting parameters and configuring VAMP relays. Via the VAMPSET software relay parameters, configurations and recorded relay data can be swapped between the operator’s PC and the VAMP relays. Supporting the COMTRADE format VAMPSET also incorporates tools for analyzing relay events, waveforms and trends from data recorded by the relays, e.g. during a network fault situation. Using a standard serial cable the PC running VAMPSET connects to the front or rear port of the VAMP...

Open the catalog to page 5
VAMP 230, VAMP 255 and VAMP 257 - 6

[Protection] VAMP 230, VAMP 255, VAMP 257 06 Hardware Communication Measurement and monitoring functions Protection functions IEEE no IEC symbol Function name

Open the catalog to page 6
VAMP 230, VAMP 255 and VAMP 257 - 7

Protection VAMP 230, VAMP 255, VAMP 257 Arc flash protection Traditional protection relay Whether the time-grading or blocking based protection coordination principle is used, the traditional protection systems may not provide fast enough protection of substation faults. Further, high-impedance type of earth-faults may cause prolonged operation times of earth-fault relays leading to the significant release of the arcing energy. These facts pose a considerable risk to human beings and economical assets. By applying a modern, high-speed arc flash protection system the damage may be...

Open the catalog to page 7

All Vamp catalogs and technical brochures

  1. vamp 265

    2 Pages

  2. VAMP 11V

    16 Pages

  3. VAMP 1 1 F

    16 Pages

  4. VAMP 50 series

    20 Pages

  5. VAMP 57

    16 Pages

  6. VAMP 259

    12 Pages

  7. VAMP 221

    16 Pages

  8. VAMP 125

    1 Pages

  9. VAMP 125

    12 Pages

  10. VAMP 11V

    16 Pages

  11. VAMP 321

    12 Pages

  12. VAMP 59

    12 Pages

  13. VAMP 55

    190 Pages

  14. VAMP 120

    8 Pages

  15. VAMP 40

    24 Pages

  16. VAMP 50

    20 Pages

  17. VAMP 230

    16 Pages

  18. VAMP 210

    2 Pages

  19. VAMP 135

    8 Pages

Archived catalogs

  1. VAMP 221

    16 Pages

  2. VAMP 96

    16 Pages

  3. ARC Protection

    20 Pages

  4. Customer

    28 Pages