VAMP 125 - 1

VAMP 125 Unit for flexible arc flash protection Modern society heavily depends on an uninterrupted supply of electric power. Prolonged power outages may cause loss of business to the power supplier and loss of production to the power consumer. An arc flash protection unit is a protective device used to enhance the environment of the installation in different situations. Schneider Electric's Vamp range is the pioneer in the field of arc flash protection with close to 15,000 arc flash systems and 300,000 sensors in service worldwide.

Open the catalog to page 1
VAMP 125 - 2

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT VAMP 125 We can supply an arc flash protection system tailored to your application An arc flash protection unit is a protective device used to enhance the environment of your installation. VAMP 125 at a glance User benefits • edicated unit for each bay D VAMP 125 Arc flash protection units are versatile and independently operating devices for bay based protection. • esigned for partners D They offer optimized and cost effective solution for panel builders and OEMs. • Hardware - Interface for 4 Arc flash sensors - 2 output relays: 1 relay output,...

Open the catalog to page 2
VAMP 125 - 4

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT Traditional time-grading or blocking based system may not be suitable to address fast answer in the event of a detected error in the installation. Further, high-impedance type earth-faults may cause prolonged operation times of earth-fault relays leading to the significant release of arcing energy. These facts pose a considerable risk to operation personnel and economical assets. Highest risk for the arc flash phenomena occurs during commissioning and maintenance of the power system and after possible recommissioning of the power distribution...

Open the catalog to page 4
VAMP 125 - 5

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT VAMP 125 user interface VAMP 125 - arc flash protection made compact, easy and effective Operating status indications Terminal X5 label texts • T1 and T2 • Auxiliary power • Blocking • Service required Terminal X2 label texts • Sensors S1, S2, S3 and S4 Sensor and trip output status • Sensors S1, S2, S3 and S4 Binary input status • External current • External master trip Terminal X1 and label texts • Binary trip out • Binary output ground Reset / Install push button • Binary master trip output / input • Block input • Reset input Panel mounting •...

Open the catalog to page 5
VAMP 125 - 6

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT www.schneider-electric.com/vamp-protection 6 The following applications are typically used for arc flash protection in MV power distribution in commercial buildings and light industries. The arc flash protection is commercialized using VAMP 125 arc flash protection units, VA1-DAx type point sensors and appropriate wiring between the units. Operation Incomer Incomer cubicle has three sensors. Activation of sensor S1 operates T1 output. Should the arc arc fault happen in the CB compartment sensor S3 activates and controls upstream CB via T2...

Open the catalog to page 6
VAMP 125 - 7

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT www.schneider-electric.com/vamp-protection 7 Point sensor VA1DAPoint sensor VA1EH Shielded arc sensor VA2DV • Typically used for MV and LV air insulated switchgears • IP 20 • Typically used for MV air insulated swichgears and wind power installations • Typically used for wind power installations in harsh environment • IP 65 • IP 65 • Tube mounting • Continuous selfsupervision • Surface mounting • Continuous selfsupervision • Placed in a hole and fixed with a nut • Continuous selfsupervision Sensor mounting plate Sensor mounting plate Door...

Open the catalog to page 7
VAMP 125 - 8

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT Dimensions and mounting VAMP 125 DIN RAIL MOUNTING Panel mounting VAMP 125 PANEL MOUNTING

Open the catalog to page 8
VAMP 125 - 9

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT www.schneider-electric.com/vamp-protection 9

Open the catalog to page 9
VAMP 125 - 10

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT

Open the catalog to page 10
VAMP 125 - 11

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT Electrical safety tests Environmental conditions Ambient te mperature, in-service Mechanical tests Test Standard & Test class / level Test value

Open the catalog to page 11
VAMP 125 - 12

VAMP RANGE // VAMP 125 ARC PROTECTION UNIT www.schneider-electric.com/vamp-protection 12 Device track record • Schneider Electric's VAMP range specialises in protection relays, arc flash protection and measuring and monitoring units for power systems. • VAMP's medium-voltage and subtransmission protection relays are used in numerous applications, from overhead line feeders and substations to power plants and industrial power system. Their integrated arc flash fault protection functionality enhances both people and property environment of care and has made VAMP a leading range in arc...

Open the catalog to page 12

All Vamp catalogs and technical brochures

  1. vamp 265

    2 Pages

  2. VAMP 11V

    16 Pages

  3. VAMP 1 1 F

    16 Pages

  4. VAMP 50 series

    20 Pages

  5. VAMP 57

    16 Pages

  6. VAMP 259

    12 Pages

  7. VAMP 221

    16 Pages

  8. VAMP 125

    1 Pages

  9. VAMP 11V

    16 Pages

  10. VAMP 321

    12 Pages

  11. VAMP 59

    12 Pages

  12. VAMP 55

    190 Pages

  13. VAMP 120

    8 Pages

  14. VAMP 40

    24 Pages

  15. VAMP 50

    20 Pages

  16. VAMP 230

    16 Pages

  17. VAMP 210

    2 Pages

  18. VAMP 135

    8 Pages

Archived catalogs

  1. VAMP 221

    16 Pages

  2. VAMP 96

    16 Pages

  3. ARC Protection

    20 Pages

  4. Customer

    28 Pages