Catalog excerpts
Arc Flash Protection Units CUSTOMER BENEFITS • Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work in or near the • Reduces Loss of Production The shorter the operating time of the arc flash protection unit the smaller the damage caused by the arc fault will be and the shorter the possible outage of the power supply • Prolonged Switchgear Life Cycle A modern arc protection unit increases the life-cycle expectancy of switchgear installations, investment decisions in new switchgear nstallations can be postponed and money can be saved by re- Vamping existing switchgear systems • Reduced Insurance Costs The faster and better the protection system of a power installation is, the more generous the insurance terms and costs will be • Low Investment Costs and Fast Installation A comprehensive arc protection is characterized by low investment costs and a fast installation and commissioning time. One successfu operation of the arc flash protection units provides immediate • Reliable Operation Function is based on appearance of light or alternatively on the appearance of light and current from an external equipment. Immune to nuisance trippings • Vast Experience Schnerider Electric is the pioneer in the field of arc flash protection with more than 10.000 VAMP arc flash protection systems and units with over 150.000 arc detecting sensors in service world-wide
Open the catalog to page 1Modern society heavily depends on an uninterrupted supply of electric power. Prolonged power outages cause loss of business to the power supplier and loss of production to the power consumer. Regardless how safe a power system is, faults do occur. This being the case the damage caused by power system faults must be kept to a minimum level. The ultimate solution is to selectively isolate the fault as fast as possible, while maintaining the operation of the healthy network parts. SECURE YOUR ASSETS AND STAFF Vamp arc flash protection maximizes the personnel safety and minimizes the material...
Open the catalog to page 2Arc Protection 04 VAMP 120/121 Product Characteristics and Highlights Common Features • Operation on light only • Support point or smoke sensors • Straight-forward installation • Cost-efficient solution • Self-supervision VAMP 120 VAMP 121 Supply unit 3P004 • Integrated 19–256 V ac/dc aux. supply • Operation on light only • Optimized for wind power and other • Up to 10 sensors • Single trip contact small applications • Operation time 9 ms • Up to 4 sensors • Selective trip for 2 zones and possibility for generator set emergency trip (including the output relay) • Binary input for blocking...
Open the catalog to page 4Arc Protection 05 VAMP 120/121 Order codes VAMP 120 Accessories Order code Description Order code Description Note V120 Arc flash protection unit VAMP4RSE VA1DA-6 VA1DA-20 VA1EH-6 VA1EH-20 Trip multiplier relay 4 x NO and 4 x NC Cable length 6 m Cable length 20 m Cable length 6 m Cable length 20 m VAMP 121 Order code Description V121 Arc flash protection unit 3P004 100-240AC / 24DC 3P007 Alarm relay VA1DA-5 Arc sensor Arc sensor Arc sensor (pipe type) Arc sensor (pipe type) Surface mounting plate for sensors Portable sensor VYX001 VYX002 Surface mounting plate for sensors Z-shaped L-shaped...
Open the catalog to page 5DIMENSIONAL DRAWINGS
Open the catalog to page 6TECHNICAL DATA Power Supply TRIP Contacts Rated voltage Continuous carry Digital Inputs Rated voltage Phoenix type as used Input Data Nominal input voltage Nominal output voltage AC input voltage range DC input voltage range Output Data Nominal output voltage Output current Power Supply Tripping Contacts Rated voltage 250 V ac/dc Breaking capacity DC, when Contact material AgNi Rated voltage Rated current / output Rated current / input Phoenix Type Coil side Nominal input voltage Un Contact type Input voltage range Limiting continuous current 6 A Nominal input current at Uin 9 mA Contact...
Open the catalog to page 7Disturbance standards Power frequency magnetic field Pulse magnetic field Damped oscillatory waves DEVICE TRACK RECORD • Schneider Electric's VAMP Range specializes in arc flash protection relays for power system • Schneider Electric VAMP's arc flash fault protection functionality enhances the safety of both people and property and has made Schneider Electric VAMP a pioneer in the field of arc flash protection with more than 10.000 VAMP arc flash systems and units with over 150.000 arc detecting sensors in service • All Schneider Electric VAMP products meet the latest international...
Open the catalog to page 8All Vamp catalogs and technical brochures
-
vamp 265
2 Pages
-
VAMP 11V
16 Pages
-
VAMP 1 1 F
16 Pages
-
VAMP 50 series
20 Pages
-
VAMP 96 and VAMP 260
12 Pages
-
VAMP 57
16 Pages
-
VAMP 259
12 Pages
-
VAMP 230, VAMP 255 and VAMP 257
16 Pages
-
VAMP 125
1 Pages
-
VAMP 125 Unit for flexible
12 Pages
-
VAMP 120 & 121
8 Pages
-
VAMP 11V
16 Pages
-
VAMP 321
12 Pages
-
VAMP 59
12 Pages
-
VAMP 55
190 Pages
-
VAMP 40
24 Pages
-
VAMP 50
20 Pages
-
VAMP 230
16 Pages
-
VAMP 210
2 Pages
-
VAMP 135
8 Pages
Archived catalogs
-
VAMP 221_2013
16 Pages
-
VAMP 221_2011
16 Pages
-
VAMP 96
16 Pages
-
ARC Protection
20 Pages
-
Customer
28 Pages
-
Vamp Arc Protection Series
16 Pages
-
Vamp Feeder/Motor Manager
16 Pages
-
Selection table
1 Pages
-
Vamp Protection Relays
16 Pages