VAMP 120 & 121
8Pages

{{requestButtons}}

Catalog excerpts

VAMP 120 & 121 - 1

Arc Flash Protection Units (k- customer benefits • Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work in or near the installation. • Reduces Loss of Production The shorter the operating time of the arc flash protection unit the smaller the damage caused by the arc fault will be and the shorter the possible outage of the power supply. • Prolonged Switchgear Life Cycle A modern arc protection unit increases the life-cycle expectancy of switchgear installations, investment decisions in new switchgear installations can be postponed and money can be saved by reVamping existing switchgear systems. • Reduced Insurance Costs The faster and better the protection system of a power installation is, the more generous the insurance terms and costs will be. • Low Investment Costs and Fast Installation A comprehensive arc protection is characterized by low investment costs and a fast installation and commissioning time. One successful operation of the arc flash protection units provides immediate investment pay off. • Reliable Operation Function is based on appearance of light or alternatively on the appearance of light and current from an external equipment. Immune to nuisance trippings! • Vast Experience Schnerider Electric is the pioneer in the field of arc flash protection with more than 10.000 VAMP arc flash protection systems and units with over 150.000 arc detecting sensors in service world-wide

Open the catalog to page 1
VAMP 120 & 121 - 2

Modern society heavily depends on an uninterrupted supply of electric power. Prolonged power outages cause loss of business to the power supplier and loss of production to the power consumer. Regardless how safe a power system is, faults do occur. This being the case the damage caused by power system faults must be kept to a minimum level. the ultimate solution is to selectively isolate the fault as fast as possible, while maintaining the operation of the healthy network parts. secure your assets and staff safety Vamp arc flash protection maximizes the personnel safety and minimizes the...

Open the catalog to page 2
VAMP 120 & 121 - 3

tyPiCAl APPliCAtions VAmP 120 applied for wind power applications G Emergency Shut Down General Trip Alarm SF Alarm Trip Signal (NC) T2 T1 VAmP 120 provides the most simple, straight- forward and economical solution designed for wind power applications VAmP 120 applied for arc flash protection at medium size power generation plant Possible arc flash in busbar or circuit breaker compartment trips the grid and all generator units. should the arc flash fault happen in cable area, an emergency shut down for the concerned generator unit is activated. General trip General trip Trip alarm ARC TRIP...

Open the catalog to page 3
VAMP 120 & 121 - 4

Product Characteristics and Highlights Common Features • Operation on light only • Support point or smoke sensors • Straight-forward installation • Cost-efficient solution • Self-supervision • Integrated 19–256 V ac/dc aux. supply • Operation on light only • Optimized for wind power and other small applications • Single trip contact • Selective trip for 2 zones and possibility for generator set emergency trip (separate contact) (including the output relay) • Binary input for blocking or resetting (programmable) the unit • Possibility for double arc channel activation (including the output...

Open the catalog to page 4
VAMP 120 & 121 - 5

order Codes VAmP 120 order code order code Arc flash protection unit Trip multiplier relay 4 x NO and 4 x NC Cable length 6 m Cable length 20 m Cable length 6 m Cable length 20 m order code Arc flash protection unit Alarm relay Arc sensor Arc sensor Arc sensor (pipe type) Arc sensor (pipe type) Surface mounting plate for sensors Portable sensor Surface mounting plate for sensors Z-shaped L-shaped TRIP Alarm ConneCtion diAgrAms SUPPLY UNIT - MINI POWER *Connection for sheeld if sheelded sensor cable used (VA1DA-20s

Open the catalog to page 5
VAMP 120 & 121 - 6

dimensionAl drAWings VAmP 120

Open the catalog to page 6
VAMP 120 & 121 - 7

VAMP 120 unit Power Supply Us Pmax Trip Contacts Rated voltage Continuous carry Make and carry for 0.5 s Make and carry for 3 s t> digital Inputs Rated voltage Number of inputs 3P004 supply unit Phoenix type as used in table below Input data Nominal input voltage Nominal output voltage AC input voltage range DC input voltage range AC frequency range DC frequency range output data Nominal output voltage Output current Power supply Us In (stand-by) I sensAct Iarc Tripping Contacts Rated voltage Continuous carry Make and carry for 0.5 s Make and carry for 3 s Breaking capacity DC, when time...

Open the catalog to page 7
VAMP 120 & 121 - 8

Static discharge (ESD) EN 61000-4-2, class III , IEC 60255-22-2 6 kV contact discharge 8 kV air discharge Fast transients (EFT) EN 61000-4-4, class IV, IEC 60255-22-4 4 kV, 5/50 ns, 5 kHz, +/-EN 61000-4-5, class III, Surge IEC 60255-22-5 1 kV, differential mode Conducted HF field EN 61000-4-6, IEC 60255-22-6 0.15 - 80 MHz, 10 V EN 61000-4-3, IEC 60255-22-3 80 - 2000 MHz, 10 V / m EN 61000-4-8 Power frequency magnetic field (VAMP 121) Emitted HF field en 61000-4-9 Pulse magnetic field (VAMP 121) IEC 60255-22-1 1 MHz Damped oscillatory waves (VAMP 121) mechanical standards...

Open the catalog to page 8

All Vamp catalogs and technical brochures

  1. vamp 265

    2 Pages

  2. VAMP 11V

    16 Pages

  3. VAMP 1 1 F

    16 Pages

  4. VAMP 50 series

    20 Pages

  5. VAMP 57

    16 Pages

  6. VAMP 259

    12 Pages

  7. VAMP 221

    16 Pages

  8. VAMP 125

    1 Pages

  9. VAMP 125

    12 Pages

  10. VAMP 11V

    16 Pages

  11. VAMP 321

    12 Pages

  12. VAMP 59

    12 Pages

  13. VAMP 55

    190 Pages

  14. VAMP 120

    8 Pages

  15. VAMP 40

    24 Pages

  16. VAMP 50

    20 Pages

  17. VAMP 230

    16 Pages

  18. VAMP 210

    2 Pages

  19. VAMP 135

    8 Pages

Archived catalogs

  1. VAMP 221

    16 Pages

  2. VAMP 96

    16 Pages

  3. ARC Protection

    20 Pages

  4. Customer

    28 Pages