video corpo

VNR 23M

VNR 23M

Product catalog summary
General Characteristics
This control unit features dual measuring channels and serves as a cost-effective interface for conductive level probes. It is designed to control liquids with a minimum electrical conductivity of 8 µS. The system measures the liquid's conductivity using low potential and alternating currents to prevent electrode incrustation and tank perforation, which are common with direct currents. The electrode's contact with the liquid triggers a relay within the control unit, allowing for control, metering, and safety systems.

Technical Data
  • Power Supply: 24 Vac 50/60 Hz (optional 230 Vac)
  • Power Consumption: 10 VA
  • Input Signal: From conductive probes
  • Output Relay: Ch1 - 2 SPDT, Ch2 - 1 SPDT
  • Sensitivity: 8 ÷ 250 µS (Factory setting: 60 µS)
  • Operation Delay: 0 ÷ 6 min (Factory setting: 1 min)
  • Operating Temperature: -20° ÷ +50° C
  • Housing: ABS IP40, 60 x 100 x 45 mm
  • Mounting: DIN rail
  • Electrical Connection: 17 poles terminal board

Control and Adjustment
  • Control: Disconnect electrode leads and short circuit specific terminals to test relay activation.
  • Sensitivity and Delay Adjustment: Adjust trimmers under the front plate to set sensitivity and operation delay.

Nomenclature
The model VNR.2300M 2CH 8 – 250 µS 24 VAC indicates type, number of channels, sensitivity, and power supply. Features include adjustable sensitivity and delay, microprocessor technology, and DIN rail mounting.
See more

Catalog excerpts

VNR 23M-1

GENERAL CHARACTERISTICS This control unit with double measuring channels was designed as low cost interface for conductive level probes and is used to control liquids that have a minimum electrical conductivity of 8 ^S. The system is based on measurement of the conductivity of the liquid to be controlled and works with low potential and with alternating currents, in order to avoid the incrustation of the electrodes and / or perforation of the tank normally caused by the use of direct currents, which cause a galvanic action on materials. The contact of the electrode with the liquid under control determines the actuation of a relay inside the control unit. The presence of two measurement channels simultaneously allows to realize systems of control, metering, and safety. • Adjustable sensitivity and delay. • 2 measuring channels • Microprocessor technology • DIN rail mounting Signal amplifier TERMINAL FUNCTION Power supply Power consumption Input signal Power supply to probes N. 2 channels Output relay Sensitivity Operation delay Adjustments Operating temperature Housing Mounting Electrical connection 24 Vac 50/60 Hz On request 230 Vac 10 VA From conductive probes 15 Vac Power supply 24 Vac 50/60 Hz Tank ground / ground electrode Minimum level electrode Maximum level electrode Trimmers under front plate -20° +50° C DIN rail 17 poles terminal board N. 2 SPDT Simultaneous action N. 1 SPDT Ch2 TYPICAL WIRING cf CONTROL AND ADJUSTMENT Control: • Disconnect the electrodes leads from the terminal board (Ch1 -terminals 5 and 6 ) (Ch2 - terminals 12 and 13 ). • Short circuit terminals 5 and 6 of the terminal board, in these conditions, the Ch1relays must switch on. • Short circuit terminals 12 and 13 of the terminal board, in these conditions, the Ch2 relays must switch on. Sensitivity and delay adjustment: • The unit is supplied with a factory setting of 60 ^S. • Submerge the electrodes in the liquid under control, turn the trimmer (Sensitivity) under the front plate to obtain the switching of the relays. • The operation delay can be adjusted with the trimmer (Delay) also located under the front plate. Type Number of channels Sensitivity Power supply We reserve the right to change the data without notice Level Flow rressun Temperature-Electronic www. valco. it

 Open the catalog to page 1

All VAL.CO srl catalogs and technical brochures

  1. LINEAR MI.SA

    3  Pages

  2. FLOW CR

    1  Page

  3. SIGHT ILV

    1  Page

  4. SIMPLE S50

    2  Pages

  5. FLOW FCM

    1  Page

  6. FILTER ZV

    1  Page

  7. FLOW MR1KV

    1  Page

  8. THERMO VSTH

    1  Page

  9. SIGHT ILC

    1  Page

  10. LINEAR S

    2  Pages

  11. LINEAR O

    2  Pages

  12. SENSOBAR 901

    3  Pages

  13. VISOBAR MCV

    1  Page

  14. LPM

    1  Page

  15. MW3

    1  Page

  16. ML

    2  Pages

  17. S1.S

    1  Page

  18. S1.P12

    1  Page

  19. SAFE SW

    1  Page

  20. SAFE ANG

    1  Page

  21. SAFE POT

    1  Page

  22. SLO

    1  Page

  23. SCV

    1  Page

  24. SLA

    1  Page

  25. SLC

    2  Pages

  26. VNR 23

    1  Page

  27. ETS series

    1  Page

  28. VST

    1  Page

  29. EPS

    1  Page

  30. SIGHT ILV

    1  Page

  31. INFO-TECH

    2  Pages

  32. level on/off

    3  Pages

  33. SENSORBAR DA

    1  Page

  34. BE126

    1  Page

  35. TPV

    1  Page

  36. KF

    2  Pages

  37. MH

    1  Page

  38. RVM

    1  Page

  39. MR1

    1  Page

  40. linear

    2  Pages

  41. O series

    2  Pages

  42. S1

    1  Page

  43. Flow switch

    1  Page

Archived catalogs

  1. Flow switch

    1  Page

  2. LEVEL On/Off

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.