video corpo

VNR 23

VNR 23

Product catalog summary
General Characteristics
The VNR2300 control unit is a cost-effective interface designed for conductive level probes, suitable for controlling liquids with a minimum electrical conductivity of 10 µS. It operates using low potential and alternating currents to prevent electrode incrustation and tank perforation, which are common with direct currents. The unit's relay is activated upon electrode contact with the liquid, enabling control of alarms or actuators. Multiple probes and control units can be connected for dosage and safety systems.
Technical Data
  • Power Supply: 24 Vac 50/60 Hz (230 Vac on request)
  • Power Consumption: 5 VA
  • Input Signal: From conductive probes
  • Power Supply to Probes: 22 Vac
  • Output Relay: 2 x SPDT 250Vac 5A
  • Sensitivity Range: 10 - 250 µS (Factory setting: 60 µS)
  • Sensitivity Adjustment: Side trimmer
  • Operating Temperature: -20° to +50° C
  • Housing: ABS
  • Degree of Protection: IP 40
  • Mounting: DIN rail
  • Dimensions: 60 x 100 x 45 mm
  • Electrical Connection: 11 poles terminal board
Control and Adjustment
Control: Disconnect electrode leads from terminals 5 and 6, then short circuit these terminals to switch on the relays.
Sensitivity Adjustment: With a factory setting of 60 µS, submerge electrodes in the liquid and adjust the side trimmer to switch the relays.
Nomenclature
The VNR2300 model includes adjustable sensitivity from 10 µS, double relay output, and DIN rail mounting. Terminal functions include power supply, tank ground, MIN/MAX level probes, and relay connections.
See more

Catalog excerpts

VNR 23-1

Signal amplifier GENERAL CHACTERISTICS The VNR2300 control unit was designed as low cost interface for conductive level probes. These electronic units are used to control liquids that have a minimum electrical conductivity of 10 pS. The system is based on measurement of the conductivity of the liquid to be controlled and works with low potential and with alternating currents, in order to avoid the incrustation of the electrodes and / or perforation of the tank normally caused by the use of direct currents, which cause a galvanic action on materials. The contact of the electrode with the liquid under control determines the actuation of a relay inside the control unit and it is possible to drive any alarm system and / or actuator. By using multiple probes and multiple control units, appropriately connected, a system of dosage and safety can be realized. • Adjustable sensitivity from 10pS. • Double relay output. • DIN rail mounting. Power supply Power consumption Input signal Power supply to probes Output relay Sensitivity range Sensitivity adjustment Operating temperature Housing Degree of protection Mounting Dimensions (mm) Electrical connection 24 Vac 50/60 Hz 230 Vac on request 5 VA From conductive probes 22 Vac 2 x SPDT 250Vac 5A 10 - 250 pS Factory setting 60pS Side trimmer -20° +50° C ABS IP 40 DIN rail 60 x 100 x 45 11 poles terminal board SENSITIVITY ADJUSTEMENT TYPICAL WIRING MIN./MAX. LEVEL ALARM Tank ground MIN. level probe MAX. level probe N.O. N.C. COM. N.O. N.C. COM. CONTROL AND ADJUSTMENT Control. Disconnect the electrodes leads from the terminal board (terminals 5 and 6). Short circuit terminals 5 and 6 of the terminal board, in these conditions, the relays must switch on. Sensitivity adjustment. The unit is supplied with a factory setting of 60 pS. Submerge the electrodes in the liquid under control, turn the side trimmer to obtain the switching of the relays. Type Tab.1 Sensitivity Tab.1 Power supply We reserve the right to change the data without notice -Level- flow -ffBSSUIB Temperature-Bedim www.valco.it

 Open the catalog to page 1

All VAL.CO srl catalogs and technical brochures

  1. LINEAR MI.SA

    3  Pages

  2. FLOW CR

    1  Page

  3. SIGHT ILV

    1  Page

  4. SIMPLE S50

    2  Pages

  5. FLOW FCM

    1  Page

  6. FILTER ZV

    1  Page

  7. FLOW MR1KV

    1  Page

  8. THERMO VSTH

    1  Page

  9. SIGHT ILC

    1  Page

  10. LINEAR S

    2  Pages

  11. LINEAR O

    2  Pages

  12. SENSOBAR 901

    3  Pages

  13. VISOBAR MCV

    1  Page

  14. LPM

    1  Page

  15. MW3

    1  Page

  16. ML

    2  Pages

  17. S1.S

    1  Page

  18. S1.P12

    1  Page

  19. SAFE SW

    1  Page

  20. SAFE ANG

    1  Page

  21. SAFE POT

    1  Page

  22. SLO

    1  Page

  23. SCV

    1  Page

  24. SLA

    1  Page

  25. SLC

    2  Pages

  26. VNR 23M

    1  Page

  27. ETS series

    1  Page

  28. VST

    1  Page

  29. EPS

    1  Page

  30. SIGHT ILV

    1  Page

  31. INFO-TECH

    2  Pages

  32. level on/off

    3  Pages

  33. SENSORBAR DA

    1  Page

  34. BE126

    1  Page

  35. TPV

    1  Page

  36. KF

    2  Pages

  37. MH

    1  Page

  38. RVM

    1  Page

  39. MR1

    1  Page

  40. linear

    2  Pages

  41. O series

    2  Pages

  42. S1

    1  Page

  43. Flow switch

    1  Page

Archived catalogs

  1. Flow switch

    1  Page

  2. LEVEL On/Off

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.